Cargando…
Long-term outcome of perimembranous VSD closure using the Nit-Occlud® Lê VSD coil system
OBJECTIVE: This study presents data from the admission trial to show the feasibility, safety and effectiveness of the Nit-Occlud® Lê VSD in the treatment of perimembranous ventricular septal defects with an aneurysmal configuration and a diameter up to 8 mm. BACKGROUND: The majority of ventricular s...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7906931/ https://www.ncbi.nlm.nih.gov/pubmed/33128576 http://dx.doi.org/10.1007/s00392-020-01750-6 |
Sumario: | OBJECTIVE: This study presents data from the admission trial to show the feasibility, safety and effectiveness of the Nit-Occlud® Lê VSD in the treatment of perimembranous ventricular septal defects with an aneurysmal configuration and a diameter up to 8 mm. BACKGROUND: The majority of ventricular septal defects (VSD) are still closed surgically, while a less invasive transcatheter treatment by closure devices is available. Device-based closure is reported to be associated with the risk of complete atrio-ventricular block, especially with double-disc devices in perimembranous defects. METHODS: In six tertiary centers in Germany and Israel, an interventional closure of a periembranous VSD was attempted in 88 patients using the Nit-Occlud® Lê VSD. RESULTS: The interventional VSD closure was performed in 85 patients. Patients had a median age of 8.0 (2–65) years and a median body weight of 26.7 (10–109) kg. A complete closure of the defects was achieved in 85.4% 2 weeks after device implantation, in 88.9% after three months and in 98.6% at the 5-year follow-up. There was no incidence of death during the study nor did any patient suffer of permanent atrio-ventricular block of higher degree. Serious adverse events, by definition, are potentially life-threatening or require surgery to correct, while major serious events require medical or transcatheter intervention to correct. The study results exhibit a serious adverse event rate of 3.5% (3/85 patients) and a major adverse event rate of 5.9% (5/85 patients). CONCLUSION: The Nit-Occlud® Lê VSD coil offers the possibility of an effective and safe approach in patients with aneurysmal perimembranous ventricular septal defects. |
---|