Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
BACKGROUND/IMS: To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). METHODS: Fifteen healthy subjects, 67% wo...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7907556/ https://www.ncbi.nlm.nih.gov/pubmed/32461263 http://dx.doi.org/10.1136/bjophthalmol-2020-316111 |
_version_ | 1783655521716273152 |
---|---|
author | Yao, Xinwen Ke, Mengyuan Ho, Yijie Lin, Emily Wong, Damon W K Tan, Bingyao Schmetterer, Leopold Chua, Jacqueline |
author_facet | Yao, Xinwen Ke, Mengyuan Ho, Yijie Lin, Emily Wong, Damon W K Tan, Bingyao Schmetterer, Leopold Chua, Jacqueline |
author_sort | Yao, Xinwen |
collection | PubMed |
description | BACKGROUND/IMS: To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). METHODS: Fifteen healthy subjects, 67% women, mean age (SD) 30.87 (6.19) years, were imaged using OCTA and AOO by a single experienced operator on the same day. Each eye was scanned using two OCTA protocols (3×3 mm(2) and 9×9 mm(2)) and two to five AOO scans (1.2×1.2 mm(2)). The OCTA and AOO scans were scaled to the same pixel resolution. Two independent graders measured the vessel diameter at the same location on the region-of-interest in the three coregistered scans. Differences in vessel diameter measurements between the scans were assessed. RESULTS: The inter-rater agreement was excellent for vessel diameter measurement in both OCTA protocols (ICC=0.92) and AOO (ICC=0.98). The measured vessel diameter was widest from the OCTA 3×3 mm(2) (55.2±16.3 µm), followed by OCTA 9×9 mm(2) (54.7±14.3 µm) and narrowest by the AOO (50.5±15.6 µm; p<0.001). Measurements obtained from both OCTA protocols were significantly wider than the AOO scan (OCTA 3×3 mm(2): mean difference Δ=4.7 µm, p<0.001; OCTA 9×9 mm(2): Δ=4.2 µm, p<0.001). For vessels >45 µm, it appeared to be larger in OCTA 3×3 mm(2) scan than the 9×9 mm(2) scan (Δ=1.9 µm; p=0.005), while vessels <45 µm appeared smaller in OCTA 3×3 mm(2) scan (Δ=−1.3 µm; p=0.009) CONCLUSIONS: The diameter of retinal vessels measured from OCTA scans were generally wider than that obtained from AOO scans. Different OCTA scan protocols may affect the vessel diameter measurements. This needs to be considered when OCTA measures such as vessel density are calculated. |
format | Online Article Text |
id | pubmed-7907556 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-79075562021-03-11 Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope Yao, Xinwen Ke, Mengyuan Ho, Yijie Lin, Emily Wong, Damon W K Tan, Bingyao Schmetterer, Leopold Chua, Jacqueline Br J Ophthalmol Clinical Science BACKGROUND/IMS: To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). METHODS: Fifteen healthy subjects, 67% women, mean age (SD) 30.87 (6.19) years, were imaged using OCTA and AOO by a single experienced operator on the same day. Each eye was scanned using two OCTA protocols (3×3 mm(2) and 9×9 mm(2)) and two to five AOO scans (1.2×1.2 mm(2)). The OCTA and AOO scans were scaled to the same pixel resolution. Two independent graders measured the vessel diameter at the same location on the region-of-interest in the three coregistered scans. Differences in vessel diameter measurements between the scans were assessed. RESULTS: The inter-rater agreement was excellent for vessel diameter measurement in both OCTA protocols (ICC=0.92) and AOO (ICC=0.98). The measured vessel diameter was widest from the OCTA 3×3 mm(2) (55.2±16.3 µm), followed by OCTA 9×9 mm(2) (54.7±14.3 µm) and narrowest by the AOO (50.5±15.6 µm; p<0.001). Measurements obtained from both OCTA protocols were significantly wider than the AOO scan (OCTA 3×3 mm(2): mean difference Δ=4.7 µm, p<0.001; OCTA 9×9 mm(2): Δ=4.2 µm, p<0.001). For vessels >45 µm, it appeared to be larger in OCTA 3×3 mm(2) scan than the 9×9 mm(2) scan (Δ=1.9 µm; p=0.005), while vessels <45 µm appeared smaller in OCTA 3×3 mm(2) scan (Δ=−1.3 µm; p=0.009) CONCLUSIONS: The diameter of retinal vessels measured from OCTA scans were generally wider than that obtained from AOO scans. Different OCTA scan protocols may affect the vessel diameter measurements. This needs to be considered when OCTA measures such as vessel density are calculated. BMJ Publishing Group 2021-03 2020-05-27 /pmc/articles/PMC7907556/ /pubmed/32461263 http://dx.doi.org/10.1136/bjophthalmol-2020-316111 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Clinical Science Yao, Xinwen Ke, Mengyuan Ho, Yijie Lin, Emily Wong, Damon W K Tan, Bingyao Schmetterer, Leopold Chua, Jacqueline Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope |
title | Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope |
title_full | Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope |
title_fullStr | Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope |
title_full_unstemmed | Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope |
title_short | Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope |
title_sort | comparison of retinal vessel diameter measurements from swept-source oct angiography and adaptive optics ophthalmoscope |
topic | Clinical Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7907556/ https://www.ncbi.nlm.nih.gov/pubmed/32461263 http://dx.doi.org/10.1136/bjophthalmol-2020-316111 |
work_keys_str_mv | AT yaoxinwen comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope AT kemengyuan comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope AT hoyijie comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope AT linemily comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope AT wongdamonwk comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope AT tanbingyao comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope AT schmettererleopold comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope AT chuajacqueline comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope |