Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope

BACKGROUND/IMS: To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). METHODS: Fifteen healthy subjects, 67% wo...

Descripción completa

Detalles Bibliográficos
Autores principales: Yao, Xinwen, Ke, Mengyuan, Ho, Yijie, Lin, Emily, Wong, Damon W K, Tan, Bingyao, Schmetterer, Leopold, Chua, Jacqueline
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7907556/
https://www.ncbi.nlm.nih.gov/pubmed/32461263
http://dx.doi.org/10.1136/bjophthalmol-2020-316111
_version_ 1783655521716273152
author Yao, Xinwen
Ke, Mengyuan
Ho, Yijie
Lin, Emily
Wong, Damon W K
Tan, Bingyao
Schmetterer, Leopold
Chua, Jacqueline
author_facet Yao, Xinwen
Ke, Mengyuan
Ho, Yijie
Lin, Emily
Wong, Damon W K
Tan, Bingyao
Schmetterer, Leopold
Chua, Jacqueline
author_sort Yao, Xinwen
collection PubMed
description BACKGROUND/IMS: To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). METHODS: Fifteen healthy subjects, 67% women, mean age (SD) 30.87 (6.19) years, were imaged using OCTA and AOO by a single experienced operator on the same day. Each eye was scanned using two OCTA protocols (3×3 mm(2) and 9×9 mm(2)) and two to five AOO scans (1.2×1.2 mm(2)). The OCTA and AOO scans were scaled to the same pixel resolution. Two independent graders measured the vessel diameter at the same location on the region-of-interest in the three coregistered scans. Differences in vessel diameter measurements between the scans were assessed. RESULTS: The inter-rater agreement was excellent for vessel diameter measurement in both OCTA protocols (ICC=0.92) and AOO (ICC=0.98). The measured vessel diameter was widest from the OCTA 3×3 mm(2) (55.2±16.3 µm), followed by OCTA 9×9 mm(2) (54.7±14.3 µm) and narrowest by the AOO (50.5±15.6 µm; p<0.001). Measurements obtained from both OCTA protocols were significantly wider than the AOO scan (OCTA 3×3 mm(2): mean difference Δ=4.7 µm, p<0.001; OCTA 9×9 mm(2): Δ=4.2 µm, p<0.001). For vessels >45 µm, it appeared to be larger in OCTA 3×3 mm(2) scan than the 9×9 mm(2) scan (Δ=1.9 µm; p=0.005), while vessels <45 µm appeared smaller in OCTA 3×3 mm(2) scan (Δ=−1.3 µm; p=0.009) CONCLUSIONS: The diameter of retinal vessels measured from OCTA scans were generally wider than that obtained from AOO scans. Different OCTA scan protocols may affect the vessel diameter measurements. This needs to be considered when OCTA measures such as vessel density are calculated.
format Online
Article
Text
id pubmed-7907556
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-79075562021-03-11 Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope Yao, Xinwen Ke, Mengyuan Ho, Yijie Lin, Emily Wong, Damon W K Tan, Bingyao Schmetterer, Leopold Chua, Jacqueline Br J Ophthalmol Clinical Science BACKGROUND/IMS: To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). METHODS: Fifteen healthy subjects, 67% women, mean age (SD) 30.87 (6.19) years, were imaged using OCTA and AOO by a single experienced operator on the same day. Each eye was scanned using two OCTA protocols (3×3 mm(2) and 9×9 mm(2)) and two to five AOO scans (1.2×1.2 mm(2)). The OCTA and AOO scans were scaled to the same pixel resolution. Two independent graders measured the vessel diameter at the same location on the region-of-interest in the three coregistered scans. Differences in vessel diameter measurements between the scans were assessed. RESULTS: The inter-rater agreement was excellent for vessel diameter measurement in both OCTA protocols (ICC=0.92) and AOO (ICC=0.98). The measured vessel diameter was widest from the OCTA 3×3 mm(2) (55.2±16.3 µm), followed by OCTA 9×9 mm(2) (54.7±14.3 µm) and narrowest by the AOO (50.5±15.6 µm; p<0.001). Measurements obtained from both OCTA protocols were significantly wider than the AOO scan (OCTA 3×3 mm(2): mean difference Δ=4.7 µm, p<0.001; OCTA 9×9 mm(2): Δ=4.2 µm, p<0.001). For vessels >45 µm, it appeared to be larger in OCTA 3×3 mm(2) scan than the 9×9 mm(2) scan (Δ=1.9 µm; p=0.005), while vessels <45 µm appeared smaller in OCTA 3×3 mm(2) scan (Δ=−1.3 µm; p=0.009) CONCLUSIONS: The diameter of retinal vessels measured from OCTA scans were generally wider than that obtained from AOO scans. Different OCTA scan protocols may affect the vessel diameter measurements. This needs to be considered when OCTA measures such as vessel density are calculated. BMJ Publishing Group 2021-03 2020-05-27 /pmc/articles/PMC7907556/ /pubmed/32461263 http://dx.doi.org/10.1136/bjophthalmol-2020-316111 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Clinical Science
Yao, Xinwen
Ke, Mengyuan
Ho, Yijie
Lin, Emily
Wong, Damon W K
Tan, Bingyao
Schmetterer, Leopold
Chua, Jacqueline
Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
title Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
title_full Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
title_fullStr Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
title_full_unstemmed Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
title_short Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
title_sort comparison of retinal vessel diameter measurements from swept-source oct angiography and adaptive optics ophthalmoscope
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7907556/
https://www.ncbi.nlm.nih.gov/pubmed/32461263
http://dx.doi.org/10.1136/bjophthalmol-2020-316111
work_keys_str_mv AT yaoxinwen comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope
AT kemengyuan comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope
AT hoyijie comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope
AT linemily comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope
AT wongdamonwk comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope
AT tanbingyao comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope
AT schmettererleopold comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope
AT chuajacqueline comparisonofretinalvesseldiametermeasurementsfromsweptsourceoctangiographyandadaptiveopticsophthalmoscope