Cargando…

The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA

These data present the 141 intracranial arterial branches' visibilities near the 72 cerebral aneurysms in postoperative 58 patients treated with titanium or cobalt-chromium-nickel-molybdenum (CCNM) alloy clips. The visibilities were evaluated using time-of-flight magnetic resonance angiography...

Descripción completa

Detalles Bibliográficos
Autores principales: Nishikawa, Akihiro, Katsuki, Masahito, Kakizawa, Yukinari, Wada, Naomichi, Yamamoto, Yasunaga, Uchiyama, Toshiya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7907704/
https://www.ncbi.nlm.nih.gov/pubmed/33665265
http://dx.doi.org/10.1016/j.dib.2021.106874
_version_ 1783655552160628736
author Nishikawa, Akihiro
Katsuki, Masahito
Kakizawa, Yukinari
Wada, Naomichi
Yamamoto, Yasunaga
Uchiyama, Toshiya
author_facet Nishikawa, Akihiro
Katsuki, Masahito
Kakizawa, Yukinari
Wada, Naomichi
Yamamoto, Yasunaga
Uchiyama, Toshiya
author_sort Nishikawa, Akihiro
collection PubMed
description These data present the 141 intracranial arterial branches' visibilities near the 72 cerebral aneurysms in postoperative 58 patients treated with titanium or cobalt-chromium-nickel-molybdenum (CCNM) alloy clips. The visibilities were evaluated using time-of-flight magnetic resonance angiography (TOF-MRA), pointwise encoding time reduction with radial acquisition (PETRA)-MRA, which uses MRA with ultrashort echo time (UTE-MRA) and subtraction technique between saturated and non-saturated images, and three-dimensional computed tomography angiography (3DCTA). We retrospectively acquired the data from the medical records of Suwa Red Cross Hospital. Each method's appearance was compared, and associations between visibility on PETRA-MRA, arterial diameter, clip numbers, clip shapes, clip materials, and amounts of hematoma were summarized. Our article on PETRA-MRA's usefulness for proximal and branched arteries evaluation after cerebral aneurysm clipping [1] was based on these data. This dataset would be useful for reference value for other neurosurgeons or radiologists for further analysis on PETRA-MRA and another UTE-MRA like SILENT-MRA after cerebral aneurysm clipping.
format Online
Article
Text
id pubmed-7907704
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-79077042021-03-03 The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA Nishikawa, Akihiro Katsuki, Masahito Kakizawa, Yukinari Wada, Naomichi Yamamoto, Yasunaga Uchiyama, Toshiya Data Brief Data Article These data present the 141 intracranial arterial branches' visibilities near the 72 cerebral aneurysms in postoperative 58 patients treated with titanium or cobalt-chromium-nickel-molybdenum (CCNM) alloy clips. The visibilities were evaluated using time-of-flight magnetic resonance angiography (TOF-MRA), pointwise encoding time reduction with radial acquisition (PETRA)-MRA, which uses MRA with ultrashort echo time (UTE-MRA) and subtraction technique between saturated and non-saturated images, and three-dimensional computed tomography angiography (3DCTA). We retrospectively acquired the data from the medical records of Suwa Red Cross Hospital. Each method's appearance was compared, and associations between visibility on PETRA-MRA, arterial diameter, clip numbers, clip shapes, clip materials, and amounts of hematoma were summarized. Our article on PETRA-MRA's usefulness for proximal and branched arteries evaluation after cerebral aneurysm clipping [1] was based on these data. This dataset would be useful for reference value for other neurosurgeons or radiologists for further analysis on PETRA-MRA and another UTE-MRA like SILENT-MRA after cerebral aneurysm clipping. Elsevier 2021-02-13 /pmc/articles/PMC7907704/ /pubmed/33665265 http://dx.doi.org/10.1016/j.dib.2021.106874 Text en © 2021 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Data Article
Nishikawa, Akihiro
Katsuki, Masahito
Kakizawa, Yukinari
Wada, Naomichi
Yamamoto, Yasunaga
Uchiyama, Toshiya
The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA
title The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA
title_full The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA
title_fullStr The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA
title_full_unstemmed The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA
title_short The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA
title_sort dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (tof-mra), and pointwise encoding time reduction with radial acquisition (petra)-mra
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7907704/
https://www.ncbi.nlm.nih.gov/pubmed/33665265
http://dx.doi.org/10.1016/j.dib.2021.106874
work_keys_str_mv AT nishikawaakihiro thedatasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT katsukimasahito thedatasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT kakizawayukinari thedatasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT wadanaomichi thedatasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT yamamotoyasunaga thedatasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT uchiyamatoshiya thedatasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT nishikawaakihiro datasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT katsukimasahito datasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT kakizawayukinari datasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT wadanaomichi datasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT yamamotoyasunaga datasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra
AT uchiyamatoshiya datasetontheclippedcerebralaneurysmandtheirradiologicalfindingsinthreedimensionalcomputedtomographytimeofflightmagneticresonanceangiographytofmraandpointwiseencodingtimereductionwithradialacquisitionpetramra