Cargando…

Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study

Left ventricular (LV) dilatation is commonly seen with LV failure and is often aggravated during venoarterial extracorporeal membrane oxygenation (VA ECMO). In this context, the intricate interaction between left and right heart function is considered to be of pivotal importance, yet mechanistically...

Descripción completa

Detalles Bibliográficos
Autores principales: Donker, Dirk w., sallisalmi, marko, broomé, michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7908866/
https://www.ncbi.nlm.nih.gov/pubmed/33627604
http://dx.doi.org/10.1097/MAT.0000000000001242
_version_ 1783655805085548544
author Donker, Dirk w.
sallisalmi, marko
broomé, michael
author_facet Donker, Dirk w.
sallisalmi, marko
broomé, michael
author_sort Donker, Dirk w.
collection PubMed
description Left ventricular (LV) dilatation is commonly seen with LV failure and is often aggravated during venoarterial extracorporeal membrane oxygenation (VA ECMO). In this context, the intricate interaction between left and right heart function is considered to be of pivotal importance, yet mechanistically not well understood. We hypothesize that a preserved or enhanced right heart contractility causes increased LV loading both with and without VA ECMO. A closed-loop in-silico simulation model containing the cardiac chambers, the pericardium, septal interactions, and the pulmonary and systemic vascular systems with an option to connect a simulated VA ECMO circuit was developed. Right ventricular contractility was modified during simulation of severe LV failure with and without VA ECMO. Left atrial pressures increased from 14.0 to 23.8 mm Hg without VA ECMO and from 18.4 to 27.0 mm Hg under VA ECMO support when right heart contractility was increased between end-systolic elastance 0.1 and 1.0 mm Hg/ml. Left-sided end-diastolic volumes increased from 125 to 169 ml without VA ECMO and from 150 to 180 ml with VA ECMO. Simulations demonstrate that increased diastolic loading of the LV may be driven by increased right ventricular contractility and that left atrial pressures cannot be interpreted as a reflection of the degree of LV dysfunction and overload without considering right ventricular function. Our study illustrates that modelling and computer simulation are important tools to unravel complex cardiovascular mechanisms underlying the right–left heart interdependency both with and without mechanical circulatory support.
format Online
Article
Text
id pubmed-7908866
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-79088662021-03-01 Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study Donker, Dirk w. sallisalmi, marko broomé, michael ASAIO J Adult Circulatory Support Left ventricular (LV) dilatation is commonly seen with LV failure and is often aggravated during venoarterial extracorporeal membrane oxygenation (VA ECMO). In this context, the intricate interaction between left and right heart function is considered to be of pivotal importance, yet mechanistically not well understood. We hypothesize that a preserved or enhanced right heart contractility causes increased LV loading both with and without VA ECMO. A closed-loop in-silico simulation model containing the cardiac chambers, the pericardium, septal interactions, and the pulmonary and systemic vascular systems with an option to connect a simulated VA ECMO circuit was developed. Right ventricular contractility was modified during simulation of severe LV failure with and without VA ECMO. Left atrial pressures increased from 14.0 to 23.8 mm Hg without VA ECMO and from 18.4 to 27.0 mm Hg under VA ECMO support when right heart contractility was increased between end-systolic elastance 0.1 and 1.0 mm Hg/ml. Left-sided end-diastolic volumes increased from 125 to 169 ml without VA ECMO and from 150 to 180 ml with VA ECMO. Simulations demonstrate that increased diastolic loading of the LV may be driven by increased right ventricular contractility and that left atrial pressures cannot be interpreted as a reflection of the degree of LV dysfunction and overload without considering right ventricular function. Our study illustrates that modelling and computer simulation are important tools to unravel complex cardiovascular mechanisms underlying the right–left heart interdependency both with and without mechanical circulatory support. Lippincott Williams & Wilkins 2020-08-05 2021-03 /pmc/articles/PMC7908866/ /pubmed/33627604 http://dx.doi.org/10.1097/MAT.0000000000001242 Text en Copyright © 2020 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the ASAIO. This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Adult Circulatory Support
Donker, Dirk w.
sallisalmi, marko
broomé, michael
Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study
title Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study
title_full Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study
title_fullStr Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study
title_full_unstemmed Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study
title_short Right–Left Ventricular Interaction in Left-Sided Heart Failure With and Without Venoarterial Extracorporeal Membrane Oxygenation Support—A Simulation Study
title_sort right–left ventricular interaction in left-sided heart failure with and without venoarterial extracorporeal membrane oxygenation support—a simulation study
topic Adult Circulatory Support
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7908866/
https://www.ncbi.nlm.nih.gov/pubmed/33627604
http://dx.doi.org/10.1097/MAT.0000000000001242
work_keys_str_mv AT donkerdirkw rightleftventricularinteractioninleftsidedheartfailurewithandwithoutvenoarterialextracorporealmembraneoxygenationsupportasimulationstudy
AT sallisalmimarko rightleftventricularinteractioninleftsidedheartfailurewithandwithoutvenoarterialextracorporealmembraneoxygenationsupportasimulationstudy
AT broomemichael rightleftventricularinteractioninleftsidedheartfailurewithandwithoutvenoarterialextracorporealmembraneoxygenationsupportasimulationstudy