Cargando…

Accuracy of Computed Tomography Attenuation Value of Lumbar Vertebra to Assess Bone Mineral Density

BACKGROUND: Computed tomography (CT) attenuation (Hounsfield unit [HU]) value of lumbar vertebra may provide an alternative method in the detection of osteoporosis during CT scans. METHODS: A cross-sectional study on 50 patients of age 50 and above with contrast-enhanced CT (CECT) and dual-energy X-...

Descripción completa

Detalles Bibliográficos
Autores principales: Chia, Kok King, Haron, Juhara, Nik Malek, Nik Fatimah Salwati
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Penerbit Universiti Sains Malaysia 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7909356/
https://www.ncbi.nlm.nih.gov/pubmed/33679219
http://dx.doi.org/10.21315/mjms2021.28.1.6
Descripción
Sumario:BACKGROUND: Computed tomography (CT) attenuation (Hounsfield unit [HU]) value of lumbar vertebra may provide an alternative method in the detection of osteoporosis during CT scans. METHODS: A cross-sectional study on 50 patients of age 50 and above with contrast-enhanced CT (CECT) and dual-energy X-ray absorptiometry (DXA) was conducted from November 2018 to November 2019. Single region of interest (ROI) was placed at the anterior trabecular part of L1 vertebra on CECT to obtain HU value. Correlation of CT HU value of L1 vertebra and DXA T-score, interrater reliability agreement between HU value of L1 vertebra and T-score in determining groups of with and without osteoporosis, ROC curve analysis for diagnostic accuracy and cut-off value of CT for detection of osteoporosis were identified. RESULTS: Significant correlation between HU value of L1 vertebra and L1 T-score (r = 0.683)/lowest skeletal T-score (r = 0.703) (P < 0.001). Substantial agreement between HU value of L1 vertebra and DXA in determining the groups with and without osteoporosis (k = 0.8; P < 0.001). The area under the receiver operating characteristic (AUROC) curve was 0.93 (95% CI: 0.86, 1.00) using HU value (P < 0.001). Cut-off value for osteoporosis was 149 HU. CONCLUSION: HU value of lumbar vertebra is an effective alternative for the detection of osteoporosis with high diagnostic accuracy in hospitals without DXA facility.