Cargando…
Assessment of Cerebral Circulatory Arrest via CT Angiography and CT Perfusion in Brain Death Confirmation
OBJECTIVE: To compare the utility of computed tomography perfusion (CTP) and three different 4-point scoring systems in computed tomography angiography (CTA) in confirming brain death (BD) in patients with and without skull defects. MATERIALS AND METHODS: Ninety-two patients clinically diagnosed as...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7909855/ https://www.ncbi.nlm.nih.gov/pubmed/32932559 http://dx.doi.org/10.3348/kjr.2019.0859 |
Sumario: | OBJECTIVE: To compare the utility of computed tomography perfusion (CTP) and three different 4-point scoring systems in computed tomography angiography (CTA) in confirming brain death (BD) in patients with and without skull defects. MATERIALS AND METHODS: Ninety-two patients clinically diagnosed as BD using CTA and/or CTP for confirmation were retrospectively reviewed. For the final analysis, 86 patients were included in this study. Images were re-evaluated by three radiologists according to the 4-point scoring systems that consider the vessel opacification on 1) the venous phase for both M4 segments of the middle cerebral arteries (MCAs-M4) and internal cerebral veins (ICVs) (A60-V60), 2) the arterial phase for the MCA-M4 and venous phase for the ICVs (A20-V60), 3) the venous phase for the ICVs and superior petrosal veins (ICV-SPV). The CTP images were independently reviewed. The presence of an open skull defect and stasis filling was noted. RESULTS: Sensitivities of the ICV-SPV, A20-V60, A60-V60 scoring systems, and CTP in the diagnosis of BD were 89.5%, 82.6%, 67.4%, and 93.3%, respectively. The sensitivity of A20-V60 scoring was higher than that of A60-V60 in BD patients (p < 0.001). CTP was found to be the most sensitive method (86.5%) in patients with open skull defect (p = 0.019). Interobserver agreement was excellent in the diagnosis of BD, in assessing A20-V60, A60-V60, ICV-SPV, CTP, and good in stasis filling (κ: 0.84, 0.83, 0.83, 0.83, and 0.67, respectively). CONCLUSION: The sensitivity of CTA confirming brain death differs between various proposed 4-point scoring systems. Although the ICV-SPV is the most sensitive, evaluation of the SPV is challenging. Adding CTP to the routine BD CTA protocol, especially in cases with open skull defect, could increase sensitivity as a useful adjunct. |
---|