Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study

BACKGROUND: Biologic technologies can potentially augment existing arthroscopic rotator cuff repair to improve retear rates and postoperative outcomes. The purpose of this study was to evaluate healing rates and clinical outcomes of full-thickness rotator cuff repairs augmented with a bioinductive b...

Descripción completa

Detalles Bibliográficos
Autores principales: Bushnell, Brandon D., Connor, Patrick M., Harris, Howard W., Ho, Charles P., Trenhaile, Scott W., Abrams, Jeffrey S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7910780/
https://www.ncbi.nlm.nih.gov/pubmed/33681842
http://dx.doi.org/10.1016/j.jseint.2020.10.020
_version_ 1783656192219807744
author Bushnell, Brandon D.
Connor, Patrick M.
Harris, Howard W.
Ho, Charles P.
Trenhaile, Scott W.
Abrams, Jeffrey S.
author_facet Bushnell, Brandon D.
Connor, Patrick M.
Harris, Howard W.
Ho, Charles P.
Trenhaile, Scott W.
Abrams, Jeffrey S.
author_sort Bushnell, Brandon D.
collection PubMed
description BACKGROUND: Biologic technologies can potentially augment existing arthroscopic rotator cuff repair to improve retear rates and postoperative outcomes. The purpose of this study was to evaluate healing rates and clinical outcomes of full-thickness rotator cuff repairs augmented with a bioinductive bovine collagen implant. METHODS: In this prospective multicenter study, investigators enrolled 115 patients (mean age, 60.4 years) with full-thickness rotator cuff tears. There were 66 (57.4%) medium (1-3 cm) tears and 49 (42.6%) large (3-5 cm) tears. Eligible patients consisted of those ≥21 years of age with chronic shoulder pain lasting longer than 3 months and unresponsive to conservative therapy. Patients underwent single- or double-row repair augmented with a bioinductive bovine collagen implant. At the baseline, 3 months, and 1 year, magnetic resonance imaging was performed and patients were assessed for American Shoulder and Elbow Surgeons (ASES) Shoulder Score and Constant-Murley Score (CMS). The primary failure end point was retear, classified as any new full-thickness defect observed on magnetic resonance imaging. RESULTS: There were 13 retears (11.3%) at 3 months, with an additional 6 (19 total [16.5%]) found at 1 year. In large tears, double-row repair had a significantly lower rate of retear at 3 months (P = .0004) and 1 year (P = .0001) compared with single-row repair. ASES and CMS scores significantly improved between the baseline and 1 year for medium and large tears. At 1 year, the minimally clinically important difference for ASES and CMS was met by 91.7% (95% CI: 84.9-96.1) and 86.4% (95% CI: 78.2-92.4) of patients, respectively. Patients without retear and those <65 years of age had significantly better CMS scores at 1 year when compared with those with retear and those ≥65 years (P < .05). There was no statistically significant difference in outcomes based on treatment of the biceps tendon. Of 9 reported reoperations in the operative shoulder, only 2 were considered potentially related to the collagen implant. CONCLUSION: Interim results from this prospective study indicate a favorable rate of retear relative to the literature and improvement in clinical function at 1 year after adjunctive treatment with the study implant augmenting standard arthroscopic repair techniques.
format Online
Article
Text
id pubmed-7910780
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-79107802021-03-05 Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study Bushnell, Brandon D. Connor, Patrick M. Harris, Howard W. Ho, Charles P. Trenhaile, Scott W. Abrams, Jeffrey S. JSES Int Shoulder BACKGROUND: Biologic technologies can potentially augment existing arthroscopic rotator cuff repair to improve retear rates and postoperative outcomes. The purpose of this study was to evaluate healing rates and clinical outcomes of full-thickness rotator cuff repairs augmented with a bioinductive bovine collagen implant. METHODS: In this prospective multicenter study, investigators enrolled 115 patients (mean age, 60.4 years) with full-thickness rotator cuff tears. There were 66 (57.4%) medium (1-3 cm) tears and 49 (42.6%) large (3-5 cm) tears. Eligible patients consisted of those ≥21 years of age with chronic shoulder pain lasting longer than 3 months and unresponsive to conservative therapy. Patients underwent single- or double-row repair augmented with a bioinductive bovine collagen implant. At the baseline, 3 months, and 1 year, magnetic resonance imaging was performed and patients were assessed for American Shoulder and Elbow Surgeons (ASES) Shoulder Score and Constant-Murley Score (CMS). The primary failure end point was retear, classified as any new full-thickness defect observed on magnetic resonance imaging. RESULTS: There were 13 retears (11.3%) at 3 months, with an additional 6 (19 total [16.5%]) found at 1 year. In large tears, double-row repair had a significantly lower rate of retear at 3 months (P = .0004) and 1 year (P = .0001) compared with single-row repair. ASES and CMS scores significantly improved between the baseline and 1 year for medium and large tears. At 1 year, the minimally clinically important difference for ASES and CMS was met by 91.7% (95% CI: 84.9-96.1) and 86.4% (95% CI: 78.2-92.4) of patients, respectively. Patients without retear and those <65 years of age had significantly better CMS scores at 1 year when compared with those with retear and those ≥65 years (P < .05). There was no statistically significant difference in outcomes based on treatment of the biceps tendon. Of 9 reported reoperations in the operative shoulder, only 2 were considered potentially related to the collagen implant. CONCLUSION: Interim results from this prospective study indicate a favorable rate of retear relative to the literature and improvement in clinical function at 1 year after adjunctive treatment with the study implant augmenting standard arthroscopic repair techniques. Elsevier 2020-12-15 /pmc/articles/PMC7910780/ /pubmed/33681842 http://dx.doi.org/10.1016/j.jseint.2020.10.020 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Shoulder
Bushnell, Brandon D.
Connor, Patrick M.
Harris, Howard W.
Ho, Charles P.
Trenhaile, Scott W.
Abrams, Jeffrey S.
Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study
title Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study
title_full Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study
title_fullStr Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study
title_full_unstemmed Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study
title_short Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study
title_sort retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study
topic Shoulder
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7910780/
https://www.ncbi.nlm.nih.gov/pubmed/33681842
http://dx.doi.org/10.1016/j.jseint.2020.10.020
work_keys_str_mv AT bushnellbrandond retearratesandclinicaloutcomesat1yearafterrepairoffullthicknessrotatorcufftearsaugmentedwithabioinductivecollagenimplantaprospectivemulticenterstudy
AT connorpatrickm retearratesandclinicaloutcomesat1yearafterrepairoffullthicknessrotatorcufftearsaugmentedwithabioinductivecollagenimplantaprospectivemulticenterstudy
AT harrishowardw retearratesandclinicaloutcomesat1yearafterrepairoffullthicknessrotatorcufftearsaugmentedwithabioinductivecollagenimplantaprospectivemulticenterstudy
AT hocharlesp retearratesandclinicaloutcomesat1yearafterrepairoffullthicknessrotatorcufftearsaugmentedwithabioinductivecollagenimplantaprospectivemulticenterstudy
AT trenhailescottw retearratesandclinicaloutcomesat1yearafterrepairoffullthicknessrotatorcufftearsaugmentedwithabioinductivecollagenimplantaprospectivemulticenterstudy
AT abramsjeffreys retearratesandclinicaloutcomesat1yearafterrepairoffullthicknessrotatorcufftearsaugmentedwithabioinductivecollagenimplantaprospectivemulticenterstudy