Cargando…
Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging
Acquiring high-quality cardiac magnetic resonance (CMR) images in patients with frequent ventricular arrhythmias remains a challenge. We examined the safety and efficacy of procainamide when administered on the scanner table prior to CMR scanning to suppress ventricular ectopy and acquire high-quali...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911068/ https://www.ncbi.nlm.nih.gov/pubmed/33513676 http://dx.doi.org/10.3390/diagnostics11020178 |
_version_ | 1783656257126662144 |
---|---|
author | Nikolaidou, Chrysovalantou Kouskouras, Konstantinos Fragakis, Nikolaos Vassilikos, Vassilios P. Karvounis, Haralambos Karamitsos, Theodoros D. |
author_facet | Nikolaidou, Chrysovalantou Kouskouras, Konstantinos Fragakis, Nikolaos Vassilikos, Vassilios P. Karvounis, Haralambos Karamitsos, Theodoros D. |
author_sort | Nikolaidou, Chrysovalantou |
collection | PubMed |
description | Acquiring high-quality cardiac magnetic resonance (CMR) images in patients with frequent ventricular arrhythmias remains a challenge. We examined the safety and efficacy of procainamide when administered on the scanner table prior to CMR scanning to suppress ventricular ectopy and acquire high-quality images. Fifty consecutive patients (age 53.0 [42.0–58.0]; 52% female, left ventricular ejection fraction 55 ± 9%) were scanned in a 1.5 T scanner using a standard cardiac protocol. Procainamide was administered at intermittent intravenous bolus doses of 50 mg every minute until suppression of the ectopics or a maximum dose of 10 mg/kg. The average dose of procainamide was 567 ± 197 mg. Procainamide successfully suppressed premature ventricular contractions (PVCs) in 82% of patients, resulting in high-quality images. The baseline blood pressure (BP) was mildly reduced (mean change systolic BP −12 ± 9 mmHg; diastolic BP −4 ± 9 mmHg), while the baseline heart rate (HR) remained relatively unchanged (mean HR change −1 ± 6 bpm). None of the patients developed proarrhythmic changes. Bolus intravenous administration of procainamide prior to CMR scanning is a safe and effective alternative approach for suppressing PVCs and acquiring high-quality images in patients with frequent PVCs and normal or only mildly reduced systolic function. |
format | Online Article Text |
id | pubmed-7911068 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79110682021-02-28 Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging Nikolaidou, Chrysovalantou Kouskouras, Konstantinos Fragakis, Nikolaos Vassilikos, Vassilios P. Karvounis, Haralambos Karamitsos, Theodoros D. Diagnostics (Basel) Article Acquiring high-quality cardiac magnetic resonance (CMR) images in patients with frequent ventricular arrhythmias remains a challenge. We examined the safety and efficacy of procainamide when administered on the scanner table prior to CMR scanning to suppress ventricular ectopy and acquire high-quality images. Fifty consecutive patients (age 53.0 [42.0–58.0]; 52% female, left ventricular ejection fraction 55 ± 9%) were scanned in a 1.5 T scanner using a standard cardiac protocol. Procainamide was administered at intermittent intravenous bolus doses of 50 mg every minute until suppression of the ectopics or a maximum dose of 10 mg/kg. The average dose of procainamide was 567 ± 197 mg. Procainamide successfully suppressed premature ventricular contractions (PVCs) in 82% of patients, resulting in high-quality images. The baseline blood pressure (BP) was mildly reduced (mean change systolic BP −12 ± 9 mmHg; diastolic BP −4 ± 9 mmHg), while the baseline heart rate (HR) remained relatively unchanged (mean HR change −1 ± 6 bpm). None of the patients developed proarrhythmic changes. Bolus intravenous administration of procainamide prior to CMR scanning is a safe and effective alternative approach for suppressing PVCs and acquiring high-quality images in patients with frequent PVCs and normal or only mildly reduced systolic function. MDPI 2021-01-27 /pmc/articles/PMC7911068/ /pubmed/33513676 http://dx.doi.org/10.3390/diagnostics11020178 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Nikolaidou, Chrysovalantou Kouskouras, Konstantinos Fragakis, Nikolaos Vassilikos, Vassilios P. Karvounis, Haralambos Karamitsos, Theodoros D. Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging |
title | Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging |
title_full | Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging |
title_fullStr | Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging |
title_full_unstemmed | Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging |
title_short | Bolus Intravenous Procainamide in Patients with Frequent Ventricular Ectopics during Cardiac Magnetic Resonance Scanning: A Way to Ensure High Quality Imaging |
title_sort | bolus intravenous procainamide in patients with frequent ventricular ectopics during cardiac magnetic resonance scanning: a way to ensure high quality imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911068/ https://www.ncbi.nlm.nih.gov/pubmed/33513676 http://dx.doi.org/10.3390/diagnostics11020178 |
work_keys_str_mv | AT nikolaidouchrysovalantou bolusintravenousprocainamideinpatientswithfrequentventricularectopicsduringcardiacmagneticresonancescanningawaytoensurehighqualityimaging AT kouskouraskonstantinos bolusintravenousprocainamideinpatientswithfrequentventricularectopicsduringcardiacmagneticresonancescanningawaytoensurehighqualityimaging AT fragakisnikolaos bolusintravenousprocainamideinpatientswithfrequentventricularectopicsduringcardiacmagneticresonancescanningawaytoensurehighqualityimaging AT vassilikosvassiliosp bolusintravenousprocainamideinpatientswithfrequentventricularectopicsduringcardiacmagneticresonancescanningawaytoensurehighqualityimaging AT karvounisharalambos bolusintravenousprocainamideinpatientswithfrequentventricularectopicsduringcardiacmagneticresonancescanningawaytoensurehighqualityimaging AT karamitsostheodorosd bolusintravenousprocainamideinpatientswithfrequentventricularectopicsduringcardiacmagneticresonancescanningawaytoensurehighqualityimaging |