Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography
The objective of the current study was to evaluate intra- and interobserver bone volume measurements and effect of orientation on the reliability of bone volume evaluation in as-acquired vis-à-vis oriented cone beam computed tomography scans using Osirix software and possible correlation between gen...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911213/ https://www.ncbi.nlm.nih.gov/pubmed/33499043 http://dx.doi.org/10.3390/dj9020014 |
_version_ | 1783656288547241984 |
---|---|
author | Kochhar, Anuraj Singh Sidhu, Maninder Singh Prabhakar, Mona Bhasin, Ritasha Kochhar, Gulsheen Kaur Dadlani, Himanshu Spagnuolo, Gianrico Mehta, Viral Vijay |
author_facet | Kochhar, Anuraj Singh Sidhu, Maninder Singh Prabhakar, Mona Bhasin, Ritasha Kochhar, Gulsheen Kaur Dadlani, Himanshu Spagnuolo, Gianrico Mehta, Viral Vijay |
author_sort | Kochhar, Anuraj Singh |
collection | PubMed |
description | The objective of the current study was to evaluate intra- and interobserver bone volume measurements and effect of orientation on the reliability of bone volume evaluation in as-acquired vis-à-vis oriented cone beam computed tomography scans using Osirix software and possible correlation between gender, age, and bone volume required. For this, 31 cone beam computed tomography (CBCT) scans of 14 girls and 17 boys (aged 9–13) with unilateral cleft lip and/or palate who met the inclusion criteria were analyzed. Efficacy and reliability of third party software Osirix for bone volume calculation was assessed using as acquired and oriented volumes by three specialists (a radiologist, an orthodontist, and an oral maxillofacial surgeon). The dataset and readings were anonymized to prevent any bias. Two-way mixed model analysis on as-acquired and oriented observations exhibited intra-class coefficient (ICC) values ≥ 0.90. Wilcoxon signed rank test (p = 0.10) and Kruskal–Wallis ANOVA (p = 0.46) indicated that although a clinical difference in volume assessment was seen between as-acquired and oriented observations (inter-observer and intra-observer), it was statistically insignificant. Spearman’s bi-variate correlation analysis revealed a significant relation between the type (side) of cleft and bone volume required to fill the defect (p < 0.05). Although there was clinical difference in bone volume measurement by the three observers, it was insignificant statistically. Clefts on the left side in the patients had significantly more bone required than the right side, whereas age and gender had no relation with bone needed to fill the defect. OsiriX software provided good reliability in measurements of bone volume. |
format | Online Article Text |
id | pubmed-7911213 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79112132021-02-28 Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography Kochhar, Anuraj Singh Sidhu, Maninder Singh Prabhakar, Mona Bhasin, Ritasha Kochhar, Gulsheen Kaur Dadlani, Himanshu Spagnuolo, Gianrico Mehta, Viral Vijay Dent J (Basel) Article The objective of the current study was to evaluate intra- and interobserver bone volume measurements and effect of orientation on the reliability of bone volume evaluation in as-acquired vis-à-vis oriented cone beam computed tomography scans using Osirix software and possible correlation between gender, age, and bone volume required. For this, 31 cone beam computed tomography (CBCT) scans of 14 girls and 17 boys (aged 9–13) with unilateral cleft lip and/or palate who met the inclusion criteria were analyzed. Efficacy and reliability of third party software Osirix for bone volume calculation was assessed using as acquired and oriented volumes by three specialists (a radiologist, an orthodontist, and an oral maxillofacial surgeon). The dataset and readings were anonymized to prevent any bias. Two-way mixed model analysis on as-acquired and oriented observations exhibited intra-class coefficient (ICC) values ≥ 0.90. Wilcoxon signed rank test (p = 0.10) and Kruskal–Wallis ANOVA (p = 0.46) indicated that although a clinical difference in volume assessment was seen between as-acquired and oriented observations (inter-observer and intra-observer), it was statistically insignificant. Spearman’s bi-variate correlation analysis revealed a significant relation between the type (side) of cleft and bone volume required to fill the defect (p < 0.05). Although there was clinical difference in bone volume measurement by the three observers, it was insignificant statistically. Clefts on the left side in the patients had significantly more bone required than the right side, whereas age and gender had no relation with bone needed to fill the defect. OsiriX software provided good reliability in measurements of bone volume. MDPI 2021-01-22 /pmc/articles/PMC7911213/ /pubmed/33499043 http://dx.doi.org/10.3390/dj9020014 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kochhar, Anuraj Singh Sidhu, Maninder Singh Prabhakar, Mona Bhasin, Ritasha Kochhar, Gulsheen Kaur Dadlani, Himanshu Spagnuolo, Gianrico Mehta, Viral Vijay Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title | Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_full | Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_fullStr | Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_full_unstemmed | Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_short | Intra- and Interobserver Reliability of Bone Volume Estimation Using OsiriX Software in Patients with Cleft Lip and Palate Using Cone Beam Computed Tomography |
title_sort | intra- and interobserver reliability of bone volume estimation using osirix software in patients with cleft lip and palate using cone beam computed tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911213/ https://www.ncbi.nlm.nih.gov/pubmed/33499043 http://dx.doi.org/10.3390/dj9020014 |
work_keys_str_mv | AT kochharanurajsingh intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT sidhumanindersingh intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT prabhakarmona intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT bhasinritasha intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT kochhargulsheenkaur intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT dadlanihimanshu intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT spagnuologianrico intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography AT mehtaviralvijay intraandinterobserverreliabilityofbonevolumeestimationusingosirixsoftwareinpatientswithcleftlipandpalateusingconebeamcomputedtomography |