Cargando…
A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers
In this paper, we report a novel teeter-totter type accelerometer based on glass-silicon composite wafers. Unlike the ordinary micro-electro-mechanical systems (MEMS) accelerometers, the entire structure of the accelerometer, includes the mass, the springs, and the composite wafer. The composite waf...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911678/ https://www.ncbi.nlm.nih.gov/pubmed/33494437 http://dx.doi.org/10.3390/mi12020102 |
_version_ | 1783656398272331776 |
---|---|
author | He, Yurong Si, Chaowei Han, Guowei Zhao, Yongmei Ning, Jin Yang, Fuhua |
author_facet | He, Yurong Si, Chaowei Han, Guowei Zhao, Yongmei Ning, Jin Yang, Fuhua |
author_sort | He, Yurong |
collection | PubMed |
description | In this paper, we report a novel teeter-totter type accelerometer based on glass-silicon composite wafers. Unlike the ordinary micro-electro-mechanical systems (MEMS) accelerometers, the entire structure of the accelerometer, includes the mass, the springs, and the composite wafer. The composite wafer is expected to serve as the electrical feedthrough and the fixed capacitance plate at the same time, to simplify the fabrication process, and to save on chip area. It is manufactured by filling melted borosilicate glass into an etched silicon wafer and polishing the wafer flat. A sensitivity of 51.622 mV/g in the range of ±5 g (g = 9.8 [Formula: see text]), a zero-bias stability under 0.2 mg, and the noise floor with 11.28 µg/√Hz were obtained, which meet the needs of most acceleration detecting applications. The micromachining solution is beneficial for vertical interconnection and miniaturization of MEMS devices. |
format | Online Article Text |
id | pubmed-7911678 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79116782021-02-28 A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers He, Yurong Si, Chaowei Han, Guowei Zhao, Yongmei Ning, Jin Yang, Fuhua Micromachines (Basel) Article In this paper, we report a novel teeter-totter type accelerometer based on glass-silicon composite wafers. Unlike the ordinary micro-electro-mechanical systems (MEMS) accelerometers, the entire structure of the accelerometer, includes the mass, the springs, and the composite wafer. The composite wafer is expected to serve as the electrical feedthrough and the fixed capacitance plate at the same time, to simplify the fabrication process, and to save on chip area. It is manufactured by filling melted borosilicate glass into an etched silicon wafer and polishing the wafer flat. A sensitivity of 51.622 mV/g in the range of ±5 g (g = 9.8 [Formula: see text]), a zero-bias stability under 0.2 mg, and the noise floor with 11.28 µg/√Hz were obtained, which meet the needs of most acceleration detecting applications. The micromachining solution is beneficial for vertical interconnection and miniaturization of MEMS devices. MDPI 2021-01-21 /pmc/articles/PMC7911678/ /pubmed/33494437 http://dx.doi.org/10.3390/mi12020102 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article He, Yurong Si, Chaowei Han, Guowei Zhao, Yongmei Ning, Jin Yang, Fuhua A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers |
title | A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers |
title_full | A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers |
title_fullStr | A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers |
title_full_unstemmed | A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers |
title_short | A Novel Fabrication Method for a Capacitive MEMS Accelerometer Based on Glass–Silicon Composite Wafers |
title_sort | novel fabrication method for a capacitive mems accelerometer based on glass–silicon composite wafers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911678/ https://www.ncbi.nlm.nih.gov/pubmed/33494437 http://dx.doi.org/10.3390/mi12020102 |
work_keys_str_mv | AT heyurong anovelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT sichaowei anovelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT hanguowei anovelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT zhaoyongmei anovelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT ningjin anovelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT yangfuhua anovelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT heyurong novelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT sichaowei novelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT hanguowei novelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT zhaoyongmei novelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT ningjin novelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers AT yangfuhua novelfabricationmethodforacapacitivememsaccelerometerbasedonglasssiliconcompositewafers |