Cargando…

Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field

The effects of using a partly curved porous layer on the thermal management and entropy generation features are studied in a ventilated cavity filled with hybrid nanofluid under the effects of inclined magnetic field by using finite volume method. This study is performed for the range of pertinent p...

Descripción completa

Detalles Bibliográficos
Autores principales: Selimefendigil, Fatih, Öztop, Hakan F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911686/
https://www.ncbi.nlm.nih.gov/pubmed/33530578
http://dx.doi.org/10.3390/e23020152
_version_ 1783656400106291200
author Selimefendigil, Fatih
Öztop, Hakan F.
author_facet Selimefendigil, Fatih
Öztop, Hakan F.
author_sort Selimefendigil, Fatih
collection PubMed
description The effects of using a partly curved porous layer on the thermal management and entropy generation features are studied in a ventilated cavity filled with hybrid nanofluid under the effects of inclined magnetic field by using finite volume method. This study is performed for the range of pertinent parameters of Reynolds number ([Formula: see text]), magnetic field strength ([Formula: see text]), permeability of porous region ([Formula: see text]), porous layer height ([Formula: see text]), porous layer position ([Formula: see text]), and curvature size ([Formula: see text]). The magnetic field reduces the vortex size, while the average Nusselt number of hot walls increases for Ha number above 20 and highest enhancement is 47% for left vertical wall. The variation in the average Nu with permeability of the layer is about 12.5% and 21% for left and right vertical walls, respectively, while these amounts are 12.5% and 32.5% when the location of the porous layer changes. The entropy generation increases with Hartmann number above 20, while there is 22% increase in the entropy generation for the case at the highest magnetic field. The porous layer height reduced the entropy generation for domain above it and it give the highest contribution to the overall entropy generation. When location of the curved porous layer is varied, the highest variation of entropy generation is attained for the domain below it while the lowest value is obtained at [Formula: see text]. When the size of elliptic curvature is varied, the overall entropy generation decreases from b = 0 to [Formula: see text] by about 10% and then increases by 5% from [Formula: see text] to [Formula: see text].
format Online
Article
Text
id pubmed-7911686
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79116862021-02-28 Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field Selimefendigil, Fatih Öztop, Hakan F. Entropy (Basel) Article The effects of using a partly curved porous layer on the thermal management and entropy generation features are studied in a ventilated cavity filled with hybrid nanofluid under the effects of inclined magnetic field by using finite volume method. This study is performed for the range of pertinent parameters of Reynolds number ([Formula: see text]), magnetic field strength ([Formula: see text]), permeability of porous region ([Formula: see text]), porous layer height ([Formula: see text]), porous layer position ([Formula: see text]), and curvature size ([Formula: see text]). The magnetic field reduces the vortex size, while the average Nusselt number of hot walls increases for Ha number above 20 and highest enhancement is 47% for left vertical wall. The variation in the average Nu with permeability of the layer is about 12.5% and 21% for left and right vertical walls, respectively, while these amounts are 12.5% and 32.5% when the location of the porous layer changes. The entropy generation increases with Hartmann number above 20, while there is 22% increase in the entropy generation for the case at the highest magnetic field. The porous layer height reduced the entropy generation for domain above it and it give the highest contribution to the overall entropy generation. When location of the curved porous layer is varied, the highest variation of entropy generation is attained for the domain below it while the lowest value is obtained at [Formula: see text]. When the size of elliptic curvature is varied, the overall entropy generation decreases from b = 0 to [Formula: see text] by about 10% and then increases by 5% from [Formula: see text] to [Formula: see text]. MDPI 2021-01-26 /pmc/articles/PMC7911686/ /pubmed/33530578 http://dx.doi.org/10.3390/e23020152 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Selimefendigil, Fatih
Öztop, Hakan F.
Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field
title Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field
title_full Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field
title_fullStr Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field
title_full_unstemmed Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field
title_short Thermal Management and Modeling of Forced Convection and Entropy Generation in a Vented Cavity by Simultaneous Use of a Curved Porous Layer and Magnetic Field
title_sort thermal management and modeling of forced convection and entropy generation in a vented cavity by simultaneous use of a curved porous layer and magnetic field
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911686/
https://www.ncbi.nlm.nih.gov/pubmed/33530578
http://dx.doi.org/10.3390/e23020152
work_keys_str_mv AT selimefendigilfatih thermalmanagementandmodelingofforcedconvectionandentropygenerationinaventedcavitybysimultaneoususeofacurvedporouslayerandmagneticfield
AT oztophakanf thermalmanagementandmodelingofforcedconvectionandentropygenerationinaventedcavitybysimultaneoususeofacurvedporouslayerandmagneticfield