Cargando…
A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection
An accurate and rapid microflow cytometry-based agglutination immunoassay (MCIA) suitable for on-site antibody or antigen detection was proposed. In this study, quantitative C-reactive protein (CRP) detection was chosen as a model assay in order to demonstrate the detection principle. The average tr...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911971/ https://www.ncbi.nlm.nih.gov/pubmed/33499089 http://dx.doi.org/10.3390/mi12020109 |
_version_ | 1783656467291701248 |
---|---|
author | Qu, Jianxi Zhang, Yushan Chenier, Mathieu Xu, Chang-qing Chen, Lan Wan, Yonghong |
author_facet | Qu, Jianxi Zhang, Yushan Chenier, Mathieu Xu, Chang-qing Chen, Lan Wan, Yonghong |
author_sort | Qu, Jianxi |
collection | PubMed |
description | An accurate and rapid microflow cytometry-based agglutination immunoassay (MCIA) suitable for on-site antibody or antigen detection was proposed. In this study, quantitative C-reactive protein (CRP) detection was chosen as a model assay in order to demonstrate the detection principle. The average transit time was employed to estimate the extent of the agglutination reaction and improve the detection accuracy as compared to the intensity-dependent methods. The detection time was less than 8 min. and only a 20 µL serum sample was needed for each test. The results showed a linear relationship between the average transit time of aggregates and CRP concentrations ranging from 0 to 1 µg/mL. The R(2) of this relationship was 0.99. The detection limit of this technology was 0.12 µg/mL CRP. The system used for CRP detection can be extended to also monitor other clinically relevant molecules. |
format | Online Article Text |
id | pubmed-7911971 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79119712021-02-28 A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection Qu, Jianxi Zhang, Yushan Chenier, Mathieu Xu, Chang-qing Chen, Lan Wan, Yonghong Micromachines (Basel) Article An accurate and rapid microflow cytometry-based agglutination immunoassay (MCIA) suitable for on-site antibody or antigen detection was proposed. In this study, quantitative C-reactive protein (CRP) detection was chosen as a model assay in order to demonstrate the detection principle. The average transit time was employed to estimate the extent of the agglutination reaction and improve the detection accuracy as compared to the intensity-dependent methods. The detection time was less than 8 min. and only a 20 µL serum sample was needed for each test. The results showed a linear relationship between the average transit time of aggregates and CRP concentrations ranging from 0 to 1 µg/mL. The R(2) of this relationship was 0.99. The detection limit of this technology was 0.12 µg/mL CRP. The system used for CRP detection can be extended to also monitor other clinically relevant molecules. MDPI 2021-01-22 /pmc/articles/PMC7911971/ /pubmed/33499089 http://dx.doi.org/10.3390/mi12020109 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Qu, Jianxi Zhang, Yushan Chenier, Mathieu Xu, Chang-qing Chen, Lan Wan, Yonghong A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection |
title | A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection |
title_full | A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection |
title_fullStr | A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection |
title_full_unstemmed | A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection |
title_short | A Transit Time-Resolved Microflow Cytometry-Based Agglutination Immunoassay for On-Site C-Reactive Protein Detection |
title_sort | transit time-resolved microflow cytometry-based agglutination immunoassay for on-site c-reactive protein detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7911971/ https://www.ncbi.nlm.nih.gov/pubmed/33499089 http://dx.doi.org/10.3390/mi12020109 |
work_keys_str_mv | AT qujianxi atransittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT zhangyushan atransittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT cheniermathieu atransittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT xuchangqing atransittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT chenlan atransittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT wanyonghong atransittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT qujianxi transittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT zhangyushan transittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT cheniermathieu transittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT xuchangqing transittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT chenlan transittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection AT wanyonghong transittimeresolvedmicroflowcytometrybasedagglutinationimmunoassayforonsitecreactiveproteindetection |