Cargando…
Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study
Recently, a smart-device-based chest compression depth (CCD) feedback system that helps ensure that chest compressions have adequate depth during cardiopulmonary resuscitation (CPR) was developed. However, no CCD feedback device has been developed for infants, and many feedback systems are inconveni...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7912179/ https://www.ncbi.nlm.nih.gov/pubmed/33525710 http://dx.doi.org/10.3390/bios11020035 |
_version_ | 1783656516441604096 |
---|---|
author | Lee, Seungjae Song, Yeongtak Lee, Jongshill Oh, Jaehoon Lim, Tae Ho Ahn, Chiwon Kim, In Young |
author_facet | Lee, Seungjae Song, Yeongtak Lee, Jongshill Oh, Jaehoon Lim, Tae Ho Ahn, Chiwon Kim, In Young |
author_sort | Lee, Seungjae |
collection | PubMed |
description | Recently, a smart-device-based chest compression depth (CCD) feedback system that helps ensure that chest compressions have adequate depth during cardiopulmonary resuscitation (CPR) was developed. However, no CCD feedback device has been developed for infants, and many feedback systems are inconvenient to use. In this paper, we report the development of a smart-ring-based CCD feedback device for CPR based on an inertial measurement unit, and propose a high-quality chest compression depth estimation algorithm that considers the orientation of the device. The performance of the proposed feedback system was evaluated by comparing it with a linear variable differential transformer in three CPR situations. The experimental results showed compression depth errors of 2.0 ± 1.1, 2.2 ± 0.9, and 1.4 ± 1.1 mm in the three situations. In addition, we conducted a pilot test with an adult/infant mannequin. The results of the experiments show that the proposed smart-ring-based CCD feedback system is applicable to various chest compression methods based on real CPR situations. |
format | Online Article Text |
id | pubmed-7912179 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79121792021-02-28 Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study Lee, Seungjae Song, Yeongtak Lee, Jongshill Oh, Jaehoon Lim, Tae Ho Ahn, Chiwon Kim, In Young Biosensors (Basel) Article Recently, a smart-device-based chest compression depth (CCD) feedback system that helps ensure that chest compressions have adequate depth during cardiopulmonary resuscitation (CPR) was developed. However, no CCD feedback device has been developed for infants, and many feedback systems are inconvenient to use. In this paper, we report the development of a smart-ring-based CCD feedback device for CPR based on an inertial measurement unit, and propose a high-quality chest compression depth estimation algorithm that considers the orientation of the device. The performance of the proposed feedback system was evaluated by comparing it with a linear variable differential transformer in three CPR situations. The experimental results showed compression depth errors of 2.0 ± 1.1, 2.2 ± 0.9, and 1.4 ± 1.1 mm in the three situations. In addition, we conducted a pilot test with an adult/infant mannequin. The results of the experiments show that the proposed smart-ring-based CCD feedback system is applicable to various chest compression methods based on real CPR situations. MDPI 2021-01-28 /pmc/articles/PMC7912179/ /pubmed/33525710 http://dx.doi.org/10.3390/bios11020035 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Seungjae Song, Yeongtak Lee, Jongshill Oh, Jaehoon Lim, Tae Ho Ahn, Chiwon Kim, In Young Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study |
title | Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study |
title_full | Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study |
title_fullStr | Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study |
title_full_unstemmed | Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study |
title_short | Development of Smart-Ring-Based Chest Compression Depth Feedback Device for High Quality Chest Compressions: A Proof-of-Concept Study |
title_sort | development of smart-ring-based chest compression depth feedback device for high quality chest compressions: a proof-of-concept study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7912179/ https://www.ncbi.nlm.nih.gov/pubmed/33525710 http://dx.doi.org/10.3390/bios11020035 |
work_keys_str_mv | AT leeseungjae developmentofsmartringbasedchestcompressiondepthfeedbackdeviceforhighqualitychestcompressionsaproofofconceptstudy AT songyeongtak developmentofsmartringbasedchestcompressiondepthfeedbackdeviceforhighqualitychestcompressionsaproofofconceptstudy AT leejongshill developmentofsmartringbasedchestcompressiondepthfeedbackdeviceforhighqualitychestcompressionsaproofofconceptstudy AT ohjaehoon developmentofsmartringbasedchestcompressiondepthfeedbackdeviceforhighqualitychestcompressionsaproofofconceptstudy AT limtaeho developmentofsmartringbasedchestcompressiondepthfeedbackdeviceforhighqualitychestcompressionsaproofofconceptstudy AT ahnchiwon developmentofsmartringbasedchestcompressiondepthfeedbackdeviceforhighqualitychestcompressionsaproofofconceptstudy AT kiminyoung developmentofsmartringbasedchestcompressiondepthfeedbackdeviceforhighqualitychestcompressionsaproofofconceptstudy |