Cargando…
Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics
PURPOSE: To compare linac-based mono-isocentric radiosurgery with Brainlab Elements Multiple Brain Mets (MBM) SRS and the Gamma Knife using a specific statistical method and to analyze the dosimetric impact of the target volume geometric characteristics. A dose fall-off analysis allowed to evaluate...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7912819/ https://www.ncbi.nlm.nih.gov/pubmed/33639959 http://dx.doi.org/10.1186/s13014-021-01766-w |
_version_ | 1783656663770726400 |
---|---|
author | Chea, Michel Fezzani, Karen Jacob, Julian Cuttat, Marguerite Croisé, Mathilde Simon, Jean-Marc Feuvret, Loïc Valery, Charles-Ambroise Maingon, Philippe Benadjaoud, Mohamed-Amine Jenny, Catherine |
author_facet | Chea, Michel Fezzani, Karen Jacob, Julian Cuttat, Marguerite Croisé, Mathilde Simon, Jean-Marc Feuvret, Loïc Valery, Charles-Ambroise Maingon, Philippe Benadjaoud, Mohamed-Amine Jenny, Catherine |
author_sort | Chea, Michel |
collection | PubMed |
description | PURPOSE: To compare linac-based mono-isocentric radiosurgery with Brainlab Elements Multiple Brain Mets (MBM) SRS and the Gamma Knife using a specific statistical method and to analyze the dosimetric impact of the target volume geometric characteristics. A dose fall-off analysis allowed to evaluate the Gradient Index relevancy for the dose spillage characterization. MATERIAL AND METHODS: Treatments were planned on twenty patients with three to nine brain metastases with MBM 2.0 and GammaPlan 11.0. Ninety-five metastases ranging from 0.02 to 9.61 cc were included. Paddick Index (PI), Gradient Index (GI), dose fall-off, volume of healthy brain receiving more than 12 Gy (V(12Gy)) and DVH were used for the plan comparison according to target volume, major axis diameter and Sphericity Index (SI). The multivariate regression approach allowed to analyze the impact of each geometric characteristic keeping all the others unchanged. A parallel study was led to evaluate the impact of the isodose line (IDL) prescription on the MBM plan quality. RESULTS: For mono-isocentric linac-based radiosurgery, the IDL around 70–75% was the best compromise found. For both techniques, the GI and the dose fall-off decreased with the target volume. In comparison, PI was slightly improved with MBM for targets < 1 cc or SI > 0.78. GI was improved with GP for targets < 2.5 cc. The V(12Gy) was higher with MBM for lesions > 0.4 cc or SI < 0.84 and exceeded 10 cc for targets > 5 cc against 6.5 cc with GP. The presence of OAR close to the PTV had no impact on the dose fall off values. The dose fall-off was higher for volumes < 3.8 cc with GP which had the sharpest dose fall-off in the infero-superior direction up to 30%/mm. The mean beam-on time was 94 min with GP against 13 min with MBM. CONCLUSIONS: The dose fall-off and the V(12Gy) were more relevant indicators than the GI for the low dose spillage assessment. Both evaluated techniques have comparable plan qualities with a slightly improved selectivity with MBM for smaller lesions but with a healthy tissues sparing slightly favorable to GP at the expense of a considerably longer irradiation time. However, a higher healthy tissue exposure must be considered for large volumes in MBM plans. |
format | Online Article Text |
id | pubmed-7912819 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-79128192021-03-02 Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics Chea, Michel Fezzani, Karen Jacob, Julian Cuttat, Marguerite Croisé, Mathilde Simon, Jean-Marc Feuvret, Loïc Valery, Charles-Ambroise Maingon, Philippe Benadjaoud, Mohamed-Amine Jenny, Catherine Radiat Oncol Research PURPOSE: To compare linac-based mono-isocentric radiosurgery with Brainlab Elements Multiple Brain Mets (MBM) SRS and the Gamma Knife using a specific statistical method and to analyze the dosimetric impact of the target volume geometric characteristics. A dose fall-off analysis allowed to evaluate the Gradient Index relevancy for the dose spillage characterization. MATERIAL AND METHODS: Treatments were planned on twenty patients with three to nine brain metastases with MBM 2.0 and GammaPlan 11.0. Ninety-five metastases ranging from 0.02 to 9.61 cc were included. Paddick Index (PI), Gradient Index (GI), dose fall-off, volume of healthy brain receiving more than 12 Gy (V(12Gy)) and DVH were used for the plan comparison according to target volume, major axis diameter and Sphericity Index (SI). The multivariate regression approach allowed to analyze the impact of each geometric characteristic keeping all the others unchanged. A parallel study was led to evaluate the impact of the isodose line (IDL) prescription on the MBM plan quality. RESULTS: For mono-isocentric linac-based radiosurgery, the IDL around 70–75% was the best compromise found. For both techniques, the GI and the dose fall-off decreased with the target volume. In comparison, PI was slightly improved with MBM for targets < 1 cc or SI > 0.78. GI was improved with GP for targets < 2.5 cc. The V(12Gy) was higher with MBM for lesions > 0.4 cc or SI < 0.84 and exceeded 10 cc for targets > 5 cc against 6.5 cc with GP. The presence of OAR close to the PTV had no impact on the dose fall off values. The dose fall-off was higher for volumes < 3.8 cc with GP which had the sharpest dose fall-off in the infero-superior direction up to 30%/mm. The mean beam-on time was 94 min with GP against 13 min with MBM. CONCLUSIONS: The dose fall-off and the V(12Gy) were more relevant indicators than the GI for the low dose spillage assessment. Both evaluated techniques have comparable plan qualities with a slightly improved selectivity with MBM for smaller lesions but with a healthy tissues sparing slightly favorable to GP at the expense of a considerably longer irradiation time. However, a higher healthy tissue exposure must be considered for large volumes in MBM plans. BioMed Central 2021-02-27 /pmc/articles/PMC7912819/ /pubmed/33639959 http://dx.doi.org/10.1186/s13014-021-01766-w Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Chea, Michel Fezzani, Karen Jacob, Julian Cuttat, Marguerite Croisé, Mathilde Simon, Jean-Marc Feuvret, Loïc Valery, Charles-Ambroise Maingon, Philippe Benadjaoud, Mohamed-Amine Jenny, Catherine Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics |
title | Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics |
title_full | Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics |
title_fullStr | Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics |
title_full_unstemmed | Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics |
title_short | Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics |
title_sort | dosimetric study between a single isocenter dynamic conformal arc therapy technique and gamma knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7912819/ https://www.ncbi.nlm.nih.gov/pubmed/33639959 http://dx.doi.org/10.1186/s13014-021-01766-w |
work_keys_str_mv | AT cheamichel dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT fezzanikaren dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT jacobjulian dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT cuttatmarguerite dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT croisemathilde dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT simonjeanmarc dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT feuvretloic dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT valerycharlesambroise dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT maingonphilippe dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT benadjaoudmohamedamine dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics AT jennycatherine dosimetricstudybetweenasingleisocenterdynamicconformalarctherapytechniqueandgammakniferadiosurgeryformultiplebrainmetastasestreatmentimpactoftargetvolumegeometricalcharacteristics |