Cargando…

Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity

Tip-enhanced Raman spectroscopy (TERS) has experienced tremendous progress over the last two decades. Despite detecting single molecules and achieving sub-nanometer spatial resolution, attaining high TERS sensitivity is still a challenging task due to low reproducibility of tip fabrication, especial...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Lu, Rahaman, Mahfujur, Madeira, Teresa I., Zahn, Dietrich R.T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7913005/
https://www.ncbi.nlm.nih.gov/pubmed/33540743
http://dx.doi.org/10.3390/nano11020376
_version_ 1783656705911947264
author He, Lu
Rahaman, Mahfujur
Madeira, Teresa I.
Zahn, Dietrich R.T.
author_facet He, Lu
Rahaman, Mahfujur
Madeira, Teresa I.
Zahn, Dietrich R.T.
author_sort He, Lu
collection PubMed
description Tip-enhanced Raman spectroscopy (TERS) has experienced tremendous progress over the last two decades. Despite detecting single molecules and achieving sub-nanometer spatial resolution, attaining high TERS sensitivity is still a challenging task due to low reproducibility of tip fabrication, especially regarding very sharp tip apices. Here, we present an approach for achieving strong TERS sensitivity via a systematic study of the near-field enhancement properties in the so-called gap-mode TERS configurations using the combination of finite element method (FEM) simulations and TERS experiments. In the simulation study, a gold tip apex is fixed at 80 nm of diameter, and the substrate consists of 20 nm high gold nanodiscs with diameter varying from 5 nm to 120 nm placed on a flat extended gold substrate. The local electric field distributions are computed in the spectral range from 500 nm to 800 nm with the tip placed both at the center and the edge of the gold nanostructure. The model is then compared with the typical gap-mode TERS configuration, in which a tip of varying diameter from 2 nm to 160 nm is placed in the proximity of a gold thin film. Our simulations show that the tip-nanodisc combined system provides much improved TERS sensitivity compared to the conventional gap-mode TERS configuration. We find that for the same tip diameter, the spatial resolution achieved in the tip-nanodisc model is much better than that observed in the conventional gap-mode TERS, which requires a very sharp metal tip to achieve the same spatial resolution on an extended metal substrate. Finally, TERS experiments are conducted on gold nanodisc arrays using home-built gold tips to validate our simulation results. Our simulations provide a guide for designing and realization of both high-spatial resolution and strong TERS intensity in future TERS experiments.
format Online
Article
Text
id pubmed-7913005
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79130052021-02-28 Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity He, Lu Rahaman, Mahfujur Madeira, Teresa I. Zahn, Dietrich R.T. Nanomaterials (Basel) Article Tip-enhanced Raman spectroscopy (TERS) has experienced tremendous progress over the last two decades. Despite detecting single molecules and achieving sub-nanometer spatial resolution, attaining high TERS sensitivity is still a challenging task due to low reproducibility of tip fabrication, especially regarding very sharp tip apices. Here, we present an approach for achieving strong TERS sensitivity via a systematic study of the near-field enhancement properties in the so-called gap-mode TERS configurations using the combination of finite element method (FEM) simulations and TERS experiments. In the simulation study, a gold tip apex is fixed at 80 nm of diameter, and the substrate consists of 20 nm high gold nanodiscs with diameter varying from 5 nm to 120 nm placed on a flat extended gold substrate. The local electric field distributions are computed in the spectral range from 500 nm to 800 nm with the tip placed both at the center and the edge of the gold nanostructure. The model is then compared with the typical gap-mode TERS configuration, in which a tip of varying diameter from 2 nm to 160 nm is placed in the proximity of a gold thin film. Our simulations show that the tip-nanodisc combined system provides much improved TERS sensitivity compared to the conventional gap-mode TERS configuration. We find that for the same tip diameter, the spatial resolution achieved in the tip-nanodisc model is much better than that observed in the conventional gap-mode TERS, which requires a very sharp metal tip to achieve the same spatial resolution on an extended metal substrate. Finally, TERS experiments are conducted on gold nanodisc arrays using home-built gold tips to validate our simulation results. Our simulations provide a guide for designing and realization of both high-spatial resolution and strong TERS intensity in future TERS experiments. MDPI 2021-02-02 /pmc/articles/PMC7913005/ /pubmed/33540743 http://dx.doi.org/10.3390/nano11020376 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
He, Lu
Rahaman, Mahfujur
Madeira, Teresa I.
Zahn, Dietrich R.T.
Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity
title Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity
title_full Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity
title_fullStr Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity
title_full_unstemmed Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity
title_short Understanding the Role of Different Substrate Geometries for Achieving Optimum Tip-Enhanced Raman Scattering Sensitivity
title_sort understanding the role of different substrate geometries for achieving optimum tip-enhanced raman scattering sensitivity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7913005/
https://www.ncbi.nlm.nih.gov/pubmed/33540743
http://dx.doi.org/10.3390/nano11020376
work_keys_str_mv AT helu understandingtheroleofdifferentsubstrategeometriesforachievingoptimumtipenhancedramanscatteringsensitivity
AT rahamanmahfujur understandingtheroleofdifferentsubstrategeometriesforachievingoptimumtipenhancedramanscatteringsensitivity
AT madeirateresai understandingtheroleofdifferentsubstrategeometriesforachievingoptimumtipenhancedramanscatteringsensitivity
AT zahndietrichrt understandingtheroleofdifferentsubstrategeometriesforachievingoptimumtipenhancedramanscatteringsensitivity