Cargando…
Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode
This report narrates the successful application of a fabricated novel sensor for the trace detection of endosulfan (EDS). The sensor was made by modifying a glassy-carbon electrode (GCE) with polyaniline (PANI), chemically synthesized antimony oxide nanoparticles (AONPs), acid-functionalized, single...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7914552/ https://www.ncbi.nlm.nih.gov/pubmed/33557284 http://dx.doi.org/10.3390/ma14040723 |
_version_ | 1783657029803442176 |
---|---|
author | Masibi, Kgotla K. Fayemi, Omolola E. Adekunle, Abolanle S. Al-Mohaimeed, Amal M. Fahim, Asmaa M. Mamba, Bhekie B. Ebenso, Eno E. |
author_facet | Masibi, Kgotla K. Fayemi, Omolola E. Adekunle, Abolanle S. Al-Mohaimeed, Amal M. Fahim, Asmaa M. Mamba, Bhekie B. Ebenso, Eno E. |
author_sort | Masibi, Kgotla K. |
collection | PubMed |
description | This report narrates the successful application of a fabricated novel sensor for the trace detection of endosulfan (EDS). The sensor was made by modifying a glassy-carbon electrode (GCE) with polyaniline (PANI), chemically synthesized antimony oxide nanoparticles (AONPs), acid-functionalized, single-walled carbon nanotubes (fSWCNTs), and finally, the AONP-PANI-SWCNT nanocomposite. The electrochemical properties of the modified electrodes regarding endosulfan detection were investigated via cyclic voltammetry (CV) and square-wave voltammetry. The current response of the electrodes to EDS followed the trend GCE-AONP-PANI-SWCNT (−510 µA) > GCE-PANI (−59 µA) > GCE-AONPs (−11.4 µA) > GCE (−5.52 µA) > GCE-fSWCNTs (−0.168 µA). The obtained results indicated that the current response obtained at the AONP-PANI-SWCNT/GCE was higher with relatively low overpotential compared to those from the other electrodes investigated. This demonstrated the superiority of the AONP-PANI-SWCNT-modified GCE. The AONP-PANI-SWCNT/GCE demonstrated good electrocatalytic activities for the electrochemical reduction of EDS. The results obtained in this study are comparable with those in other reports. The sensitivity, limit of detection (LoD), and limit of quantification (LoQ) of AONP-PANI-SWCNT/GCE towards EDS was estimated to be 0.0623 µA/µM, 6.8 µM, and 20.6 µM, respectively. Selectivity, as well as the practical application of the fabricated sensor, were explored, and the results indicated that the EDS-reduction current was reduced by only 2.0% when interfering species were present, whilst average recoveries of EDS in real samples were above 97%. |
format | Online Article Text |
id | pubmed-7914552 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79145522021-03-01 Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode Masibi, Kgotla K. Fayemi, Omolola E. Adekunle, Abolanle S. Al-Mohaimeed, Amal M. Fahim, Asmaa M. Mamba, Bhekie B. Ebenso, Eno E. Materials (Basel) Article This report narrates the successful application of a fabricated novel sensor for the trace detection of endosulfan (EDS). The sensor was made by modifying a glassy-carbon electrode (GCE) with polyaniline (PANI), chemically synthesized antimony oxide nanoparticles (AONPs), acid-functionalized, single-walled carbon nanotubes (fSWCNTs), and finally, the AONP-PANI-SWCNT nanocomposite. The electrochemical properties of the modified electrodes regarding endosulfan detection were investigated via cyclic voltammetry (CV) and square-wave voltammetry. The current response of the electrodes to EDS followed the trend GCE-AONP-PANI-SWCNT (−510 µA) > GCE-PANI (−59 µA) > GCE-AONPs (−11.4 µA) > GCE (−5.52 µA) > GCE-fSWCNTs (−0.168 µA). The obtained results indicated that the current response obtained at the AONP-PANI-SWCNT/GCE was higher with relatively low overpotential compared to those from the other electrodes investigated. This demonstrated the superiority of the AONP-PANI-SWCNT-modified GCE. The AONP-PANI-SWCNT/GCE demonstrated good electrocatalytic activities for the electrochemical reduction of EDS. The results obtained in this study are comparable with those in other reports. The sensitivity, limit of detection (LoD), and limit of quantification (LoQ) of AONP-PANI-SWCNT/GCE towards EDS was estimated to be 0.0623 µA/µM, 6.8 µM, and 20.6 µM, respectively. Selectivity, as well as the practical application of the fabricated sensor, were explored, and the results indicated that the EDS-reduction current was reduced by only 2.0% when interfering species were present, whilst average recoveries of EDS in real samples were above 97%. MDPI 2021-02-04 /pmc/articles/PMC7914552/ /pubmed/33557284 http://dx.doi.org/10.3390/ma14040723 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Masibi, Kgotla K. Fayemi, Omolola E. Adekunle, Abolanle S. Al-Mohaimeed, Amal M. Fahim, Asmaa M. Mamba, Bhekie B. Ebenso, Eno E. Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode |
title | Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode |
title_full | Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode |
title_fullStr | Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode |
title_full_unstemmed | Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode |
title_short | Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode |
title_sort | electrochemical detection of endosulfan using an aonp-pani-swcnt modified glassy carbon electrode |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7914552/ https://www.ncbi.nlm.nih.gov/pubmed/33557284 http://dx.doi.org/10.3390/ma14040723 |
work_keys_str_mv | AT masibikgotlak electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode AT fayemiomololae electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode AT adekunleabolanles electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode AT almohaimeedamalm electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode AT fahimasmaam electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode AT mambabhekieb electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode AT ebensoenoe electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode |