Cargando…

Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode

This report narrates the successful application of a fabricated novel sensor for the trace detection of endosulfan (EDS). The sensor was made by modifying a glassy-carbon electrode (GCE) with polyaniline (PANI), chemically synthesized antimony oxide nanoparticles (AONPs), acid-functionalized, single...

Descripción completa

Detalles Bibliográficos
Autores principales: Masibi, Kgotla K., Fayemi, Omolola E., Adekunle, Abolanle S., Al-Mohaimeed, Amal M., Fahim, Asmaa M., Mamba, Bhekie B., Ebenso, Eno E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7914552/
https://www.ncbi.nlm.nih.gov/pubmed/33557284
http://dx.doi.org/10.3390/ma14040723
_version_ 1783657029803442176
author Masibi, Kgotla K.
Fayemi, Omolola E.
Adekunle, Abolanle S.
Al-Mohaimeed, Amal M.
Fahim, Asmaa M.
Mamba, Bhekie B.
Ebenso, Eno E.
author_facet Masibi, Kgotla K.
Fayemi, Omolola E.
Adekunle, Abolanle S.
Al-Mohaimeed, Amal M.
Fahim, Asmaa M.
Mamba, Bhekie B.
Ebenso, Eno E.
author_sort Masibi, Kgotla K.
collection PubMed
description This report narrates the successful application of a fabricated novel sensor for the trace detection of endosulfan (EDS). The sensor was made by modifying a glassy-carbon electrode (GCE) with polyaniline (PANI), chemically synthesized antimony oxide nanoparticles (AONPs), acid-functionalized, single-walled carbon nanotubes (fSWCNTs), and finally, the AONP-PANI-SWCNT nanocomposite. The electrochemical properties of the modified electrodes regarding endosulfan detection were investigated via cyclic voltammetry (CV) and square-wave voltammetry. The current response of the electrodes to EDS followed the trend GCE-AONP-PANI-SWCNT (−510 µA) > GCE-PANI (−59 µA) > GCE-AONPs (−11.4 µA) > GCE (−5.52 µA) > GCE-fSWCNTs (−0.168 µA). The obtained results indicated that the current response obtained at the AONP-PANI-SWCNT/GCE was higher with relatively low overpotential compared to those from the other electrodes investigated. This demonstrated the superiority of the AONP-PANI-SWCNT-modified GCE. The AONP-PANI-SWCNT/GCE demonstrated good electrocatalytic activities for the electrochemical reduction of EDS. The results obtained in this study are comparable with those in other reports. The sensitivity, limit of detection (LoD), and limit of quantification (LoQ) of AONP-PANI-SWCNT/GCE towards EDS was estimated to be 0.0623 µA/µM, 6.8 µM, and 20.6 µM, respectively. Selectivity, as well as the practical application of the fabricated sensor, were explored, and the results indicated that the EDS-reduction current was reduced by only 2.0% when interfering species were present, whilst average recoveries of EDS in real samples were above 97%.
format Online
Article
Text
id pubmed-7914552
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79145522021-03-01 Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode Masibi, Kgotla K. Fayemi, Omolola E. Adekunle, Abolanle S. Al-Mohaimeed, Amal M. Fahim, Asmaa M. Mamba, Bhekie B. Ebenso, Eno E. Materials (Basel) Article This report narrates the successful application of a fabricated novel sensor for the trace detection of endosulfan (EDS). The sensor was made by modifying a glassy-carbon electrode (GCE) with polyaniline (PANI), chemically synthesized antimony oxide nanoparticles (AONPs), acid-functionalized, single-walled carbon nanotubes (fSWCNTs), and finally, the AONP-PANI-SWCNT nanocomposite. The electrochemical properties of the modified electrodes regarding endosulfan detection were investigated via cyclic voltammetry (CV) and square-wave voltammetry. The current response of the electrodes to EDS followed the trend GCE-AONP-PANI-SWCNT (−510 µA) > GCE-PANI (−59 µA) > GCE-AONPs (−11.4 µA) > GCE (−5.52 µA) > GCE-fSWCNTs (−0.168 µA). The obtained results indicated that the current response obtained at the AONP-PANI-SWCNT/GCE was higher with relatively low overpotential compared to those from the other electrodes investigated. This demonstrated the superiority of the AONP-PANI-SWCNT-modified GCE. The AONP-PANI-SWCNT/GCE demonstrated good electrocatalytic activities for the electrochemical reduction of EDS. The results obtained in this study are comparable with those in other reports. The sensitivity, limit of detection (LoD), and limit of quantification (LoQ) of AONP-PANI-SWCNT/GCE towards EDS was estimated to be 0.0623 µA/µM, 6.8 µM, and 20.6 µM, respectively. Selectivity, as well as the practical application of the fabricated sensor, were explored, and the results indicated that the EDS-reduction current was reduced by only 2.0% when interfering species were present, whilst average recoveries of EDS in real samples were above 97%. MDPI 2021-02-04 /pmc/articles/PMC7914552/ /pubmed/33557284 http://dx.doi.org/10.3390/ma14040723 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Masibi, Kgotla K.
Fayemi, Omolola E.
Adekunle, Abolanle S.
Al-Mohaimeed, Amal M.
Fahim, Asmaa M.
Mamba, Bhekie B.
Ebenso, Eno E.
Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode
title Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode
title_full Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode
title_fullStr Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode
title_full_unstemmed Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode
title_short Electrochemical Detection of Endosulfan Using an AONP-PANI-SWCNT Modified Glassy Carbon Electrode
title_sort electrochemical detection of endosulfan using an aonp-pani-swcnt modified glassy carbon electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7914552/
https://www.ncbi.nlm.nih.gov/pubmed/33557284
http://dx.doi.org/10.3390/ma14040723
work_keys_str_mv AT masibikgotlak electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode
AT fayemiomololae electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode
AT adekunleabolanles electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode
AT almohaimeedamalm electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode
AT fahimasmaam electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode
AT mambabhekieb electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode
AT ebensoenoe electrochemicaldetectionofendosulfanusinganaonppaniswcntmodifiedglassycarbonelectrode