Cargando…

Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles

Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This in...

Descripción completa

Detalles Bibliográficos
Autores principales: Jaufenthaler, Aaron, Kornack, Thomas, Lebedev, Victor, Limes, Mark E., Körber, Rainer, Liebl, Maik, Baumgarten, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7915455/
https://www.ncbi.nlm.nih.gov/pubmed/33572285
http://dx.doi.org/10.3390/s21041212
_version_ 1783657243142520832
author Jaufenthaler, Aaron
Kornack, Thomas
Lebedev, Victor
Limes, Mark E.
Körber, Rainer
Liebl, Maik
Baumgarten, Daniel
author_facet Jaufenthaler, Aaron
Kornack, Thomas
Lebedev, Victor
Limes, Mark E.
Körber, Rainer
Liebl, Maik
Baumgarten, Daniel
author_sort Jaufenthaler, Aaron
collection PubMed
description Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This information can be obtained by means of magnetorelaxometry (MRX), where the relaxation of previously aligned magnetic moments of MNP is measured. Current MRX with optically pumped magnetometers (OPM) is limited by OPM recovery time after the shut-off of the external magnetic field for MNP alignment, therewith preventing the detection of fast relaxing MNP. We present a setup for OPM-MRX measurements using a commercially available pulsed free-precession OPM, where the use of a high power pulsed pump laser in the sensor enables a system recovery time in the microsecond range. Besides, magnetometer raw data processing techniques for Larmor frequency analysis are proposed and compared in this paper. Due to the high bandwidth ([Formula: see text]) and high dynamic range of our OPM, a software gradiometer in a compact enclosure allows for unshielded MRX measurements in a laboratory environment. When operated in the MRX mode with non-optimal pumping performance, the OPM shows an unshielded gradiometric noise floor of about [Formula: see text] for a [Formula: see text] baseline. The noise floor is flat up to [Formula: see text] and increases then linearly with the frequency. We demonstrate that quantitative unshielded MRX measurements of fast relaxing, water suspended MNP is possible with the novel OPM-MRX concept, confirmed by the accurately derived iron amount ratios of MNP samples. The detection limit of the current setup is about [Formula: see text] of iron for a liquid BNF-MNP-sample (Bionized NanoFerrite) with a volume of [Formula: see text].
format Online
Article
Text
id pubmed-7915455
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79154552021-03-01 Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles Jaufenthaler, Aaron Kornack, Thomas Lebedev, Victor Limes, Mark E. Körber, Rainer Liebl, Maik Baumgarten, Daniel Sensors (Basel) Article Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This information can be obtained by means of magnetorelaxometry (MRX), where the relaxation of previously aligned magnetic moments of MNP is measured. Current MRX with optically pumped magnetometers (OPM) is limited by OPM recovery time after the shut-off of the external magnetic field for MNP alignment, therewith preventing the detection of fast relaxing MNP. We present a setup for OPM-MRX measurements using a commercially available pulsed free-precession OPM, where the use of a high power pulsed pump laser in the sensor enables a system recovery time in the microsecond range. Besides, magnetometer raw data processing techniques for Larmor frequency analysis are proposed and compared in this paper. Due to the high bandwidth ([Formula: see text]) and high dynamic range of our OPM, a software gradiometer in a compact enclosure allows for unshielded MRX measurements in a laboratory environment. When operated in the MRX mode with non-optimal pumping performance, the OPM shows an unshielded gradiometric noise floor of about [Formula: see text] for a [Formula: see text] baseline. The noise floor is flat up to [Formula: see text] and increases then linearly with the frequency. We demonstrate that quantitative unshielded MRX measurements of fast relaxing, water suspended MNP is possible with the novel OPM-MRX concept, confirmed by the accurately derived iron amount ratios of MNP samples. The detection limit of the current setup is about [Formula: see text] of iron for a liquid BNF-MNP-sample (Bionized NanoFerrite) with a volume of [Formula: see text]. MDPI 2021-02-09 /pmc/articles/PMC7915455/ /pubmed/33572285 http://dx.doi.org/10.3390/s21041212 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jaufenthaler, Aaron
Kornack, Thomas
Lebedev, Victor
Limes, Mark E.
Körber, Rainer
Liebl, Maik
Baumgarten, Daniel
Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles
title Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles
title_full Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles
title_fullStr Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles
title_full_unstemmed Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles
title_short Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles
title_sort pulsed optically pumped magnetometers: addressing dead time and bandwidth for the unshielded magnetorelaxometry of magnetic nanoparticles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7915455/
https://www.ncbi.nlm.nih.gov/pubmed/33572285
http://dx.doi.org/10.3390/s21041212
work_keys_str_mv AT jaufenthaleraaron pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles
AT kornackthomas pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles
AT lebedevvictor pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles
AT limesmarke pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles
AT korberrainer pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles
AT lieblmaik pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles
AT baumgartendaniel pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles