Cargando…
Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles
Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This in...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7915455/ https://www.ncbi.nlm.nih.gov/pubmed/33572285 http://dx.doi.org/10.3390/s21041212 |
_version_ | 1783657243142520832 |
---|---|
author | Jaufenthaler, Aaron Kornack, Thomas Lebedev, Victor Limes, Mark E. Körber, Rainer Liebl, Maik Baumgarten, Daniel |
author_facet | Jaufenthaler, Aaron Kornack, Thomas Lebedev, Victor Limes, Mark E. Körber, Rainer Liebl, Maik Baumgarten, Daniel |
author_sort | Jaufenthaler, Aaron |
collection | PubMed |
description | Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This information can be obtained by means of magnetorelaxometry (MRX), where the relaxation of previously aligned magnetic moments of MNP is measured. Current MRX with optically pumped magnetometers (OPM) is limited by OPM recovery time after the shut-off of the external magnetic field for MNP alignment, therewith preventing the detection of fast relaxing MNP. We present a setup for OPM-MRX measurements using a commercially available pulsed free-precession OPM, where the use of a high power pulsed pump laser in the sensor enables a system recovery time in the microsecond range. Besides, magnetometer raw data processing techniques for Larmor frequency analysis are proposed and compared in this paper. Due to the high bandwidth ([Formula: see text]) and high dynamic range of our OPM, a software gradiometer in a compact enclosure allows for unshielded MRX measurements in a laboratory environment. When operated in the MRX mode with non-optimal pumping performance, the OPM shows an unshielded gradiometric noise floor of about [Formula: see text] for a [Formula: see text] baseline. The noise floor is flat up to [Formula: see text] and increases then linearly with the frequency. We demonstrate that quantitative unshielded MRX measurements of fast relaxing, water suspended MNP is possible with the novel OPM-MRX concept, confirmed by the accurately derived iron amount ratios of MNP samples. The detection limit of the current setup is about [Formula: see text] of iron for a liquid BNF-MNP-sample (Bionized NanoFerrite) with a volume of [Formula: see text]. |
format | Online Article Text |
id | pubmed-7915455 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79154552021-03-01 Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles Jaufenthaler, Aaron Kornack, Thomas Lebedev, Victor Limes, Mark E. Körber, Rainer Liebl, Maik Baumgarten, Daniel Sensors (Basel) Article Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This information can be obtained by means of magnetorelaxometry (MRX), where the relaxation of previously aligned magnetic moments of MNP is measured. Current MRX with optically pumped magnetometers (OPM) is limited by OPM recovery time after the shut-off of the external magnetic field for MNP alignment, therewith preventing the detection of fast relaxing MNP. We present a setup for OPM-MRX measurements using a commercially available pulsed free-precession OPM, where the use of a high power pulsed pump laser in the sensor enables a system recovery time in the microsecond range. Besides, magnetometer raw data processing techniques for Larmor frequency analysis are proposed and compared in this paper. Due to the high bandwidth ([Formula: see text]) and high dynamic range of our OPM, a software gradiometer in a compact enclosure allows for unshielded MRX measurements in a laboratory environment. When operated in the MRX mode with non-optimal pumping performance, the OPM shows an unshielded gradiometric noise floor of about [Formula: see text] for a [Formula: see text] baseline. The noise floor is flat up to [Formula: see text] and increases then linearly with the frequency. We demonstrate that quantitative unshielded MRX measurements of fast relaxing, water suspended MNP is possible with the novel OPM-MRX concept, confirmed by the accurately derived iron amount ratios of MNP samples. The detection limit of the current setup is about [Formula: see text] of iron for a liquid BNF-MNP-sample (Bionized NanoFerrite) with a volume of [Formula: see text]. MDPI 2021-02-09 /pmc/articles/PMC7915455/ /pubmed/33572285 http://dx.doi.org/10.3390/s21041212 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Jaufenthaler, Aaron Kornack, Thomas Lebedev, Victor Limes, Mark E. Körber, Rainer Liebl, Maik Baumgarten, Daniel Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles |
title | Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles |
title_full | Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles |
title_fullStr | Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles |
title_full_unstemmed | Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles |
title_short | Pulsed Optically Pumped Magnetometers: Addressing Dead Time and Bandwidth for the Unshielded Magnetorelaxometry of Magnetic Nanoparticles |
title_sort | pulsed optically pumped magnetometers: addressing dead time and bandwidth for the unshielded magnetorelaxometry of magnetic nanoparticles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7915455/ https://www.ncbi.nlm.nih.gov/pubmed/33572285 http://dx.doi.org/10.3390/s21041212 |
work_keys_str_mv | AT jaufenthaleraaron pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles AT kornackthomas pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles AT lebedevvictor pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles AT limesmarke pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles AT korberrainer pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles AT lieblmaik pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles AT baumgartendaniel pulsedopticallypumpedmagnetometersaddressingdeadtimeandbandwidthfortheunshieldedmagnetorelaxometryofmagneticnanoparticles |