Cargando…

Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study

Vein puncture is commonly used for blood sampling, and accurately locating the blood vessel is an important challenge in the field of diagnostic tests. Imaging systems based on near-infrared (NIR) light are widely used for accurate human vein puncture. In particular, segmentation of a region of inte...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Kyuseok, Jeong, Hyun-Woo, Lee, Youngjin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7915855/
https://www.ncbi.nlm.nih.gov/pubmed/33561967
http://dx.doi.org/10.3390/ijerph18041548
_version_ 1783657344141361152
author Kim, Kyuseok
Jeong, Hyun-Woo
Lee, Youngjin
author_facet Kim, Kyuseok
Jeong, Hyun-Woo
Lee, Youngjin
author_sort Kim, Kyuseok
collection PubMed
description Vein puncture is commonly used for blood sampling, and accurately locating the blood vessel is an important challenge in the field of diagnostic tests. Imaging systems based on near-infrared (NIR) light are widely used for accurate human vein puncture. In particular, segmentation of a region of interest using the obtained NIR image is an important field, and research for improving the image quality by removing noise and enhancing the image contrast is being widely conducted. In this paper, we propose an effective model in which the relative total variation (RTV) regularization algorithm and contrast-limited adaptive histogram equalization (CLAHE) are combined, whereby some major edge information can be better preserved. In our previous study, we developed a miniaturized NIR imaging system using light with a wavelength of 720–1100 nm. We evaluated the usefulness of the proposed algorithm by applying it to images acquired by the developed NIR imaging system. Compared with the conventional algorithm, when the proposed method was applied to the NIR image, the visual evaluation performance and quantitative evaluation performance were enhanced. In particular, when the proposed algorithm was applied, the coefficient of variation was improved by a factor of 15.77 compared with the basic image. The main advantages of our algorithm are the high noise reduction efficiency, which is beneficial for reducing the amount of undesirable information, and better contrast. In conclusion, the applicability and usefulness of the algorithm combining the RTV approach and CLAHE for NIR images were demonstrated, and the proposed model can achieve a high image quality.
format Online
Article
Text
id pubmed-7915855
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79158552021-03-01 Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study Kim, Kyuseok Jeong, Hyun-Woo Lee, Youngjin Int J Environ Res Public Health Article Vein puncture is commonly used for blood sampling, and accurately locating the blood vessel is an important challenge in the field of diagnostic tests. Imaging systems based on near-infrared (NIR) light are widely used for accurate human vein puncture. In particular, segmentation of a region of interest using the obtained NIR image is an important field, and research for improving the image quality by removing noise and enhancing the image contrast is being widely conducted. In this paper, we propose an effective model in which the relative total variation (RTV) regularization algorithm and contrast-limited adaptive histogram equalization (CLAHE) are combined, whereby some major edge information can be better preserved. In our previous study, we developed a miniaturized NIR imaging system using light with a wavelength of 720–1100 nm. We evaluated the usefulness of the proposed algorithm by applying it to images acquired by the developed NIR imaging system. Compared with the conventional algorithm, when the proposed method was applied to the NIR image, the visual evaluation performance and quantitative evaluation performance were enhanced. In particular, when the proposed algorithm was applied, the coefficient of variation was improved by a factor of 15.77 compared with the basic image. The main advantages of our algorithm are the high noise reduction efficiency, which is beneficial for reducing the amount of undesirable information, and better contrast. In conclusion, the applicability and usefulness of the algorithm combining the RTV approach and CLAHE for NIR images were demonstrated, and the proposed model can achieve a high image quality. MDPI 2021-02-06 2021-02 /pmc/articles/PMC7915855/ /pubmed/33561967 http://dx.doi.org/10.3390/ijerph18041548 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Kyuseok
Jeong, Hyun-Woo
Lee, Youngjin
Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study
title Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study
title_full Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study
title_fullStr Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study
title_full_unstemmed Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study
title_short Performance Evaluation of Dorsal Vein Network of Hand Imaging Using Relative Total Variation-Based Regularization for Smoothing Technique in a Miniaturized Vein Imaging System: A Pilot Study
title_sort performance evaluation of dorsal vein network of hand imaging using relative total variation-based regularization for smoothing technique in a miniaturized vein imaging system: a pilot study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7915855/
https://www.ncbi.nlm.nih.gov/pubmed/33561967
http://dx.doi.org/10.3390/ijerph18041548
work_keys_str_mv AT kimkyuseok performanceevaluationofdorsalveinnetworkofhandimagingusingrelativetotalvariationbasedregularizationforsmoothingtechniqueinaminiaturizedveinimagingsystemapilotstudy
AT jeonghyunwoo performanceevaluationofdorsalveinnetworkofhandimagingusingrelativetotalvariationbasedregularizationforsmoothingtechniqueinaminiaturizedveinimagingsystemapilotstudy
AT leeyoungjin performanceevaluationofdorsalveinnetworkofhandimagingusingrelativetotalvariationbasedregularizationforsmoothingtechniqueinaminiaturizedveinimagingsystemapilotstudy