Cargando…

Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo

Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessme...

Descripción completa

Detalles Bibliográficos
Autores principales: Mazzoli, Valentina, Moulin, Kevin, Kogan, Feliks, Hargreaves, Brian A., Gold, Garry E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917051/
https://www.ncbi.nlm.nih.gov/pubmed/33658976
http://dx.doi.org/10.3389/fneur.2021.608549
_version_ 1783657615292628992
author Mazzoli, Valentina
Moulin, Kevin
Kogan, Feliks
Hargreaves, Brian A.
Gold, Garry E.
author_facet Mazzoli, Valentina
Moulin, Kevin
Kogan, Feliks
Hargreaves, Brian A.
Gold, Garry E.
author_sort Mazzoli, Valentina
collection PubMed
description Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessment of non-contracted musculature, therefore providing limited insight into muscle contraction mechanisms and contraction abnormalities. In this study, we propose the use of an oscillating gradient spin echo (OGSE) diffusion encoding strategy for DTI measurements to mitigate the effect of signal voids in contracted muscle and to obtain reliable diffusivity values. Two OGSE sequences with encoding frequencies of 25 and 50 Hz were tested in the lower leg of five healthy volunteers with relaxed musculature and during active dorsiflexion and plantarflexion, and compared with a conventional PGSE approach. A significant reduction of areas of signal voids using OGSE compared with PGSE was observed in the tibialis anterior for the scans obtained in active dorsiflexion and in the soleus during active plantarflexion. The use of PGSE sequences led to unrealistically elevated axial diffusivity values in the tibialis anterior during dorsiflexion and in the soleus during plantarflexion, while the corresponding values obtained using the OGSE sequences were significantly reduced. Similar findings were seen for radial diffusivity, with significantly higher diffusivity measured in plantarflexion in the soleus muscle using the PGSE sequence. Our preliminary results indicate that DTI with OGSE diffusion encoding is feasible in human musculature and allows to quantitatively assess diffusion properties in actively contracting skeletal muscle. OGSE holds great potential to assess microstructural changes occurring in the skeletal muscle during contraction, and for non-invasive assessment of contraction abnormalities in patients with muscle diseases.
format Online
Article
Text
id pubmed-7917051
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-79170512021-03-02 Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo Mazzoli, Valentina Moulin, Kevin Kogan, Feliks Hargreaves, Brian A. Gold, Garry E. Front Neurol Neurology Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessment of non-contracted musculature, therefore providing limited insight into muscle contraction mechanisms and contraction abnormalities. In this study, we propose the use of an oscillating gradient spin echo (OGSE) diffusion encoding strategy for DTI measurements to mitigate the effect of signal voids in contracted muscle and to obtain reliable diffusivity values. Two OGSE sequences with encoding frequencies of 25 and 50 Hz were tested in the lower leg of five healthy volunteers with relaxed musculature and during active dorsiflexion and plantarflexion, and compared with a conventional PGSE approach. A significant reduction of areas of signal voids using OGSE compared with PGSE was observed in the tibialis anterior for the scans obtained in active dorsiflexion and in the soleus during active plantarflexion. The use of PGSE sequences led to unrealistically elevated axial diffusivity values in the tibialis anterior during dorsiflexion and in the soleus during plantarflexion, while the corresponding values obtained using the OGSE sequences were significantly reduced. Similar findings were seen for radial diffusivity, with significantly higher diffusivity measured in plantarflexion in the soleus muscle using the PGSE sequence. Our preliminary results indicate that DTI with OGSE diffusion encoding is feasible in human musculature and allows to quantitatively assess diffusion properties in actively contracting skeletal muscle. OGSE holds great potential to assess microstructural changes occurring in the skeletal muscle during contraction, and for non-invasive assessment of contraction abnormalities in patients with muscle diseases. Frontiers Media S.A. 2021-02-15 /pmc/articles/PMC7917051/ /pubmed/33658976 http://dx.doi.org/10.3389/fneur.2021.608549 Text en Copyright © 2021 Mazzoli, Moulin, Kogan, Hargreaves and Gold. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Mazzoli, Valentina
Moulin, Kevin
Kogan, Feliks
Hargreaves, Brian A.
Gold, Garry E.
Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo
title Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo
title_full Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo
title_fullStr Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo
title_full_unstemmed Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo
title_short Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo
title_sort diffusion tensor imaging of skeletal muscle contraction using oscillating gradient spin echo
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917051/
https://www.ncbi.nlm.nih.gov/pubmed/33658976
http://dx.doi.org/10.3389/fneur.2021.608549
work_keys_str_mv AT mazzolivalentina diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho
AT moulinkevin diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho
AT koganfeliks diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho
AT hargreavesbriana diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho
AT goldgarrye diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho