Cargando…
Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo
Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessme...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917051/ https://www.ncbi.nlm.nih.gov/pubmed/33658976 http://dx.doi.org/10.3389/fneur.2021.608549 |
_version_ | 1783657615292628992 |
---|---|
author | Mazzoli, Valentina Moulin, Kevin Kogan, Feliks Hargreaves, Brian A. Gold, Garry E. |
author_facet | Mazzoli, Valentina Moulin, Kevin Kogan, Feliks Hargreaves, Brian A. Gold, Garry E. |
author_sort | Mazzoli, Valentina |
collection | PubMed |
description | Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessment of non-contracted musculature, therefore providing limited insight into muscle contraction mechanisms and contraction abnormalities. In this study, we propose the use of an oscillating gradient spin echo (OGSE) diffusion encoding strategy for DTI measurements to mitigate the effect of signal voids in contracted muscle and to obtain reliable diffusivity values. Two OGSE sequences with encoding frequencies of 25 and 50 Hz were tested in the lower leg of five healthy volunteers with relaxed musculature and during active dorsiflexion and plantarflexion, and compared with a conventional PGSE approach. A significant reduction of areas of signal voids using OGSE compared with PGSE was observed in the tibialis anterior for the scans obtained in active dorsiflexion and in the soleus during active plantarflexion. The use of PGSE sequences led to unrealistically elevated axial diffusivity values in the tibialis anterior during dorsiflexion and in the soleus during plantarflexion, while the corresponding values obtained using the OGSE sequences were significantly reduced. Similar findings were seen for radial diffusivity, with significantly higher diffusivity measured in plantarflexion in the soleus muscle using the PGSE sequence. Our preliminary results indicate that DTI with OGSE diffusion encoding is feasible in human musculature and allows to quantitatively assess diffusion properties in actively contracting skeletal muscle. OGSE holds great potential to assess microstructural changes occurring in the skeletal muscle during contraction, and for non-invasive assessment of contraction abnormalities in patients with muscle diseases. |
format | Online Article Text |
id | pubmed-7917051 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-79170512021-03-02 Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo Mazzoli, Valentina Moulin, Kevin Kogan, Feliks Hargreaves, Brian A. Gold, Garry E. Front Neurol Neurology Diffusion tensor imaging (DTI) measures water diffusion in skeletal muscle tissue and allows for muscle assessment in a broad range of neuromuscular diseases. However, current DTI measurements, typically performed using pulsed gradient spin echo (PGSE) diffusion encoding, are limited to the assessment of non-contracted musculature, therefore providing limited insight into muscle contraction mechanisms and contraction abnormalities. In this study, we propose the use of an oscillating gradient spin echo (OGSE) diffusion encoding strategy for DTI measurements to mitigate the effect of signal voids in contracted muscle and to obtain reliable diffusivity values. Two OGSE sequences with encoding frequencies of 25 and 50 Hz were tested in the lower leg of five healthy volunteers with relaxed musculature and during active dorsiflexion and plantarflexion, and compared with a conventional PGSE approach. A significant reduction of areas of signal voids using OGSE compared with PGSE was observed in the tibialis anterior for the scans obtained in active dorsiflexion and in the soleus during active plantarflexion. The use of PGSE sequences led to unrealistically elevated axial diffusivity values in the tibialis anterior during dorsiflexion and in the soleus during plantarflexion, while the corresponding values obtained using the OGSE sequences were significantly reduced. Similar findings were seen for radial diffusivity, with significantly higher diffusivity measured in plantarflexion in the soleus muscle using the PGSE sequence. Our preliminary results indicate that DTI with OGSE diffusion encoding is feasible in human musculature and allows to quantitatively assess diffusion properties in actively contracting skeletal muscle. OGSE holds great potential to assess microstructural changes occurring in the skeletal muscle during contraction, and for non-invasive assessment of contraction abnormalities in patients with muscle diseases. Frontiers Media S.A. 2021-02-15 /pmc/articles/PMC7917051/ /pubmed/33658976 http://dx.doi.org/10.3389/fneur.2021.608549 Text en Copyright © 2021 Mazzoli, Moulin, Kogan, Hargreaves and Gold. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Mazzoli, Valentina Moulin, Kevin Kogan, Feliks Hargreaves, Brian A. Gold, Garry E. Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo |
title | Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo |
title_full | Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo |
title_fullStr | Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo |
title_full_unstemmed | Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo |
title_short | Diffusion Tensor Imaging of Skeletal Muscle Contraction Using Oscillating Gradient Spin Echo |
title_sort | diffusion tensor imaging of skeletal muscle contraction using oscillating gradient spin echo |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917051/ https://www.ncbi.nlm.nih.gov/pubmed/33658976 http://dx.doi.org/10.3389/fneur.2021.608549 |
work_keys_str_mv | AT mazzolivalentina diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho AT moulinkevin diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho AT koganfeliks diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho AT hargreavesbriana diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho AT goldgarrye diffusiontensorimagingofskeletalmusclecontractionusingoscillatinggradientspinecho |