On the Response of a Micro Non-Destructive Testing X-ray Detector

Certain imaging performance metrics are examined for a state-of-the-art 20 μm pixel pitch CMOS sensor (RadEye HR), coupled to a Gd(2)O(2)S:Tb scintillator screen. The signal transfer property (STP), the modulation transfer function (MTF), the normalized noise power spectrum (NNPS) and the detective...

Descripción completa

Detalles Bibliográficos
Autores principales: Linardatos, Dionysios, Koukou, Vaia, Martini, Niki, Konstantinidis, Anastasios, Bakas, Athanasios, Fountos, George, Valais, Ioannis, Michail, Christos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917680/
https://www.ncbi.nlm.nih.gov/pubmed/33668484
http://dx.doi.org/10.3390/ma14040888
_version_ 1783657753053495296
author Linardatos, Dionysios
Koukou, Vaia
Martini, Niki
Konstantinidis, Anastasios
Bakas, Athanasios
Fountos, George
Valais, Ioannis
Michail, Christos
author_facet Linardatos, Dionysios
Koukou, Vaia
Martini, Niki
Konstantinidis, Anastasios
Bakas, Athanasios
Fountos, George
Valais, Ioannis
Michail, Christos
author_sort Linardatos, Dionysios
collection PubMed
description Certain imaging performance metrics are examined for a state-of-the-art 20 μm pixel pitch CMOS sensor (RadEye HR), coupled to a Gd(2)O(2)S:Tb scintillator screen. The signal transfer property (STP), the modulation transfer function (MTF), the normalized noise power spectrum (NNPS) and the detective quantum efficiency (DQE) were estimated according to the IEC 62220-1-1:2015 standard. The detector exhibits excellent linearity (coefficient of determination of the STP linear regression fit, R(2) was 0.9978), while its DQE peaks at 33% and reaches 10% at a spatial frequency of 3 cycles/mm, for the measured with a Piranha RTI dosimeter (coefficient of variation CV = 0.03%) exposure value of 28.1 μGy DAK (detector Air Kerma). The resolution capabilities of the X-ray detector under investigation were compared to other commercial CMOS sensors, and were found in every case higher, except from the previous RadEye HR model (CMOS—Gd(2)O(2)S:Tb screen pair with 22.5 μm pixel pitch) version which had slightly better MTF. The present digital imager is designed for industrial inspection applications, nonetheless its applicability to medical imaging, as well as dual-energy is considered and certain approaches are discussed in this respect.
format Online
Article
Text
id pubmed-7917680
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79176802021-03-02 On the Response of a Micro Non-Destructive Testing X-ray Detector Linardatos, Dionysios Koukou, Vaia Martini, Niki Konstantinidis, Anastasios Bakas, Athanasios Fountos, George Valais, Ioannis Michail, Christos Materials (Basel) Article Certain imaging performance metrics are examined for a state-of-the-art 20 μm pixel pitch CMOS sensor (RadEye HR), coupled to a Gd(2)O(2)S:Tb scintillator screen. The signal transfer property (STP), the modulation transfer function (MTF), the normalized noise power spectrum (NNPS) and the detective quantum efficiency (DQE) were estimated according to the IEC 62220-1-1:2015 standard. The detector exhibits excellent linearity (coefficient of determination of the STP linear regression fit, R(2) was 0.9978), while its DQE peaks at 33% and reaches 10% at a spatial frequency of 3 cycles/mm, for the measured with a Piranha RTI dosimeter (coefficient of variation CV = 0.03%) exposure value of 28.1 μGy DAK (detector Air Kerma). The resolution capabilities of the X-ray detector under investigation were compared to other commercial CMOS sensors, and were found in every case higher, except from the previous RadEye HR model (CMOS—Gd(2)O(2)S:Tb screen pair with 22.5 μm pixel pitch) version which had slightly better MTF. The present digital imager is designed for industrial inspection applications, nonetheless its applicability to medical imaging, as well as dual-energy is considered and certain approaches are discussed in this respect. MDPI 2021-02-13 /pmc/articles/PMC7917680/ /pubmed/33668484 http://dx.doi.org/10.3390/ma14040888 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Linardatos, Dionysios
Koukou, Vaia
Martini, Niki
Konstantinidis, Anastasios
Bakas, Athanasios
Fountos, George
Valais, Ioannis
Michail, Christos
On the Response of a Micro Non-Destructive Testing X-ray Detector
title On the Response of a Micro Non-Destructive Testing X-ray Detector
title_full On the Response of a Micro Non-Destructive Testing X-ray Detector
title_fullStr On the Response of a Micro Non-Destructive Testing X-ray Detector
title_full_unstemmed On the Response of a Micro Non-Destructive Testing X-ray Detector
title_short On the Response of a Micro Non-Destructive Testing X-ray Detector
title_sort on the response of a micro non-destructive testing x-ray detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917680/
https://www.ncbi.nlm.nih.gov/pubmed/33668484
http://dx.doi.org/10.3390/ma14040888
work_keys_str_mv AT linardatosdionysios ontheresponseofamicronondestructivetestingxraydetector
AT koukouvaia ontheresponseofamicronondestructivetestingxraydetector
AT martininiki ontheresponseofamicronondestructivetestingxraydetector
AT konstantinidisanastasios ontheresponseofamicronondestructivetestingxraydetector
AT bakasathanasios ontheresponseofamicronondestructivetestingxraydetector
AT fountosgeorge ontheresponseofamicronondestructivetestingxraydetector
AT valaisioannis ontheresponseofamicronondestructivetestingxraydetector
AT michailchristos ontheresponseofamicronondestructivetestingxraydetector