Cargando…

The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years

OBJECTIVES: The objective was to evaluate the clinical results of a new surgical technique to improve the Bankart repair by adding a prosthetic block called the Recenter. METHODS: Thirty-two patients were retrospectively included in this multicenter study. Five patients were lost to follow-up. The s...

Descripción completa

Detalles Bibliográficos
Autores principales: Picard, Kevin, Werthel, Jean-David, Toussaint, Bruno, Bauer, Thomas, Hardy, Alexandre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917838/
http://dx.doi.org/10.1177/2325967121S00001
_version_ 1783657789522968576
author Picard, Kevin
Werthel, Jean-David
Toussaint, Bruno
Bauer, Thomas
Hardy, Alexandre
author_facet Picard, Kevin
Werthel, Jean-David
Toussaint, Bruno
Bauer, Thomas
Hardy, Alexandre
author_sort Picard, Kevin
collection PubMed
description OBJECTIVES: The objective was to evaluate the clinical results of a new surgical technique to improve the Bankart repair by adding a prosthetic block called the Recenter. METHODS: Thirty-two patients were retrospectively included in this multicenter study. Five patients were lost to follow-up. The surgical indications were similar to those for a standard Bankart repair. A metal implant called a Recenter was inserted in the anterior inferior glenoid and fixed with two TightRopes. A Bankart repair was then performed over the implant. All the patients had a follow-up CT scan and a clinical examination. The mean follow-up period was 37 months (29-47). The mean ISIS score was 2.42 (0-6). RESULTS: Twenty-six patients aged 33.9 ± 10.2 (16-50) years were included. Patients presented with an average of 2.4 ± 3.2 (0-12) true dislocations prior to surgery and 6.1 ± 8.5 (0-30) subluxations. The time that had elapsed between the occurrence of the first symptoms and surgery was 6.8 ± 6.9 years. The last follow-up showed a residual VAS score of 1.3. The mean Walch-Duplay score was 78.9 ± 21.4 - SD (range 5-100), the mean ROWE score, 88.5 ± 15.9 - SD (30-100) and the mean SST score, 90.6 ± 14.5 - SD (41.6-100). 77.8% of the patients (n=21) had no apprehension, 11.1% (n=3) were apprehensive, 7.4% (n=2) were afraid of the possibility of luxation and 3.7% (n=1) had a recurrence. In terms of satisfaction, 59.3% were very satisfied, 33.3% satisfied and 7.4% dissatisfied with their operation. Concerning the CT study, we found no shifting of material or ballooning of the TightRope tunnels. CONCLUSION: The Recenter showed a recurrence rate of 4% (1 patient) with an average follow-up of 3 years. Despite a small number of patients, the Recenter appears to be a worthwhile addition to the arthroscopic Bankart technique.
format Online
Article
Text
id pubmed-7917838
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-79178382021-03-11 The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years Picard, Kevin Werthel, Jean-David Toussaint, Bruno Bauer, Thomas Hardy, Alexandre Orthop J Sports Med Article OBJECTIVES: The objective was to evaluate the clinical results of a new surgical technique to improve the Bankart repair by adding a prosthetic block called the Recenter. METHODS: Thirty-two patients were retrospectively included in this multicenter study. Five patients were lost to follow-up. The surgical indications were similar to those for a standard Bankart repair. A metal implant called a Recenter was inserted in the anterior inferior glenoid and fixed with two TightRopes. A Bankart repair was then performed over the implant. All the patients had a follow-up CT scan and a clinical examination. The mean follow-up period was 37 months (29-47). The mean ISIS score was 2.42 (0-6). RESULTS: Twenty-six patients aged 33.9 ± 10.2 (16-50) years were included. Patients presented with an average of 2.4 ± 3.2 (0-12) true dislocations prior to surgery and 6.1 ± 8.5 (0-30) subluxations. The time that had elapsed between the occurrence of the first symptoms and surgery was 6.8 ± 6.9 years. The last follow-up showed a residual VAS score of 1.3. The mean Walch-Duplay score was 78.9 ± 21.4 - SD (range 5-100), the mean ROWE score, 88.5 ± 15.9 - SD (30-100) and the mean SST score, 90.6 ± 14.5 - SD (41.6-100). 77.8% of the patients (n=21) had no apprehension, 11.1% (n=3) were apprehensive, 7.4% (n=2) were afraid of the possibility of luxation and 3.7% (n=1) had a recurrence. In terms of satisfaction, 59.3% were very satisfied, 33.3% satisfied and 7.4% dissatisfied with their operation. Concerning the CT study, we found no shifting of material or ballooning of the TightRope tunnels. CONCLUSION: The Recenter showed a recurrence rate of 4% (1 patient) with an average follow-up of 3 years. Despite a small number of patients, the Recenter appears to be a worthwhile addition to the arthroscopic Bankart technique. SAGE Publications 2021-02-26 /pmc/articles/PMC7917838/ http://dx.doi.org/10.1177/2325967121S00001 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Picard, Kevin
Werthel, Jean-David
Toussaint, Bruno
Bauer, Thomas
Hardy, Alexandre
The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years
title The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years
title_full The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years
title_fullStr The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years
title_full_unstemmed The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years
title_short The Recenter: an augmented Bankart. Results with a minimum follow-up of 2 years
title_sort recenter: an augmented bankart. results with a minimum follow-up of 2 years
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917838/
http://dx.doi.org/10.1177/2325967121S00001
work_keys_str_mv AT picardkevin therecenteranaugmentedbankartresultswithaminimumfollowupof2years
AT wertheljeandavid therecenteranaugmentedbankartresultswithaminimumfollowupof2years
AT toussaintbruno therecenteranaugmentedbankartresultswithaminimumfollowupof2years
AT bauerthomas therecenteranaugmentedbankartresultswithaminimumfollowupof2years
AT hardyalexandre therecenteranaugmentedbankartresultswithaminimumfollowupof2years
AT picardkevin recenteranaugmentedbankartresultswithaminimumfollowupof2years
AT wertheljeandavid recenteranaugmentedbankartresultswithaminimumfollowupof2years
AT toussaintbruno recenteranaugmentedbankartresultswithaminimumfollowupof2years
AT bauerthomas recenteranaugmentedbankartresultswithaminimumfollowupof2years
AT hardyalexandre recenteranaugmentedbankartresultswithaminimumfollowupof2years