Cargando…

Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes †

SIMPLE SUMMARY: This work investigates the effect of skin tissue heterogeneity on the sensing depth of the open-ended coaxial probe to exploit the potential use of the probe for skin cancer detection and to establish a simple measurement protocol for skin depth characterization. Skin depth was calcu...

Descripción completa

Detalles Bibliográficos
Autores principales: Aydinalp, Cemanur, Joof, Sulayman, Yilmaz, Tuba
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7918258/
https://www.ncbi.nlm.nih.gov/pubmed/33673259
http://dx.doi.org/10.3390/s21041319
_version_ 1783657885197139968
author Aydinalp, Cemanur
Joof, Sulayman
Yilmaz, Tuba
author_facet Aydinalp, Cemanur
Joof, Sulayman
Yilmaz, Tuba
author_sort Aydinalp, Cemanur
collection PubMed
description SIMPLE SUMMARY: This work investigates the effect of skin tissue heterogeneity on the sensing depth of the open-ended coaxial probe to exploit the potential use of the probe for skin cancer detection and to establish a simple measurement protocol for skin depth characterization. Skin depth was calculated through simulations and measurements. Heterogeneity was obtained using double-layered materials composed of gel-like skin mimicking material and liquid olive oil, triton X-100. It was concluded that the sensing depth was not dependent on the frequency between 0.5 to 6 GHz, was affected by the material located at the aperture of the probe, and lastly the dielectric property contrast between layers. Namely the degree of heterogeneity affects the probe sensing depth. ABSTRACT: Dielectric properties of biological tissues are traditionally measured with open-ended coaxial probes. Despite being commercially available for laboratory use, the technique suffers from high measurement error. This prevents the practical applications of the open-ended coaxial probes. One such application is the utilization of the technique for skin cancer detection. To enable a diagnostic tool, there is a need to address the error sources. Among others, tissue heterogeneity is a major contributor to measurement error. The effect of tissue heterogeneity on measurement accuracy can be decreased by quantifying the probe sensing depth. To this end, this work (1) investigates the sensing depth of the 2.2 mm-diameter open-ended coaxial probe for skin mimicking material and (2) offers a simple experimental setup and protocol for sensing depth characterization of open-ended coaxial probes. The sensing depth characterized through simulation and experiments using two double-layered configurations composed to mimic the skin tissue heterogeneity. Three thresholds in percent increase of dielectric property measurements were chosen to determine the sensing depth. Based on the experiment results, it was concluded that the sensing depth was effected by the dielectric property contrast between the layers. That is, high contrast results in rapid change whereas low contrast results in a slower change in measured dielectric properties. It was also concluded that the sensing depth was independent of frequency between 0.5 to 6 GHz and was mostly determined by the material located immediately at the aperture of the probe.
format Online
Article
Text
id pubmed-7918258
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79182582021-03-02 Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes † Aydinalp, Cemanur Joof, Sulayman Yilmaz, Tuba Sensors (Basel) Article SIMPLE SUMMARY: This work investigates the effect of skin tissue heterogeneity on the sensing depth of the open-ended coaxial probe to exploit the potential use of the probe for skin cancer detection and to establish a simple measurement protocol for skin depth characterization. Skin depth was calculated through simulations and measurements. Heterogeneity was obtained using double-layered materials composed of gel-like skin mimicking material and liquid olive oil, triton X-100. It was concluded that the sensing depth was not dependent on the frequency between 0.5 to 6 GHz, was affected by the material located at the aperture of the probe, and lastly the dielectric property contrast between layers. Namely the degree of heterogeneity affects the probe sensing depth. ABSTRACT: Dielectric properties of biological tissues are traditionally measured with open-ended coaxial probes. Despite being commercially available for laboratory use, the technique suffers from high measurement error. This prevents the practical applications of the open-ended coaxial probes. One such application is the utilization of the technique for skin cancer detection. To enable a diagnostic tool, there is a need to address the error sources. Among others, tissue heterogeneity is a major contributor to measurement error. The effect of tissue heterogeneity on measurement accuracy can be decreased by quantifying the probe sensing depth. To this end, this work (1) investigates the sensing depth of the 2.2 mm-diameter open-ended coaxial probe for skin mimicking material and (2) offers a simple experimental setup and protocol for sensing depth characterization of open-ended coaxial probes. The sensing depth characterized through simulation and experiments using two double-layered configurations composed to mimic the skin tissue heterogeneity. Three thresholds in percent increase of dielectric property measurements were chosen to determine the sensing depth. Based on the experiment results, it was concluded that the sensing depth was effected by the dielectric property contrast between the layers. That is, high contrast results in rapid change whereas low contrast results in a slower change in measured dielectric properties. It was also concluded that the sensing depth was independent of frequency between 0.5 to 6 GHz and was mostly determined by the material located immediately at the aperture of the probe. MDPI 2021-02-12 /pmc/articles/PMC7918258/ /pubmed/33673259 http://dx.doi.org/10.3390/s21041319 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Aydinalp, Cemanur
Joof, Sulayman
Yilmaz, Tuba
Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes †
title Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes †
title_full Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes †
title_fullStr Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes †
title_full_unstemmed Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes †
title_short Towards Non-Invasive Diagnosis of Skin Cancer: Sensing Depth Investigation of Open-Ended Coaxial Probes †
title_sort towards non-invasive diagnosis of skin cancer: sensing depth investigation of open-ended coaxial probes †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7918258/
https://www.ncbi.nlm.nih.gov/pubmed/33673259
http://dx.doi.org/10.3390/s21041319
work_keys_str_mv AT aydinalpcemanur towardsnoninvasivediagnosisofskincancersensingdepthinvestigationofopenendedcoaxialprobes
AT joofsulayman towardsnoninvasivediagnosisofskincancersensingdepthinvestigationofopenendedcoaxialprobes
AT yilmaztuba towardsnoninvasivediagnosisofskincancersensingdepthinvestigationofopenendedcoaxialprobes