Cargando…

Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora

Compared with traditional gas chromatography–mass spectrometry techniques, electronic noses are non-invasive and can be a rapid, cost-effective option for several applications. This paper presents comparative studies of differentiation between odors emitted by two forest pathogens: Pythium and Phyto...

Descripción completa

Detalles Bibliográficos
Autores principales: Borowik, Piotr, Adamowicz, Leszek, Tarakowski, Rafał, Wacławik, Przemysław, Oszako, Tomasz, Ślusarski, Sławomir, Tkaczyk, Miłosz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7918289/
https://www.ncbi.nlm.nih.gov/pubmed/33668511
http://dx.doi.org/10.3390/s21041326
_version_ 1783657889466941440
author Borowik, Piotr
Adamowicz, Leszek
Tarakowski, Rafał
Wacławik, Przemysław
Oszako, Tomasz
Ślusarski, Sławomir
Tkaczyk, Miłosz
author_facet Borowik, Piotr
Adamowicz, Leszek
Tarakowski, Rafał
Wacławik, Przemysław
Oszako, Tomasz
Ślusarski, Sławomir
Tkaczyk, Miłosz
author_sort Borowik, Piotr
collection PubMed
description Compared with traditional gas chromatography–mass spectrometry techniques, electronic noses are non-invasive and can be a rapid, cost-effective option for several applications. This paper presents comparative studies of differentiation between odors emitted by two forest pathogens: Pythium and Phytophthora, measured by a low-cost electronic nose. The electronic nose applies six non-specific Figaro Inc. metal oxide sensors. Various features describing shapes of the measurement curves of sensors’ response to the odors’ exposure were extracted and used for building the classification models. As a machine learning algorithm for classification, we use the Support Vector Machine (SVM) method and various measures to assess classification models’ performance. Differentiation between Phytophthora and Pythium species has an important practical aspect allowing forest practitioners to take appropriate plant protection. We demonstrate the possibility to recognize and differentiate between the two mentioned species with acceptable accuracy by our low-cost electronic nose.
format Online
Article
Text
id pubmed-7918289
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79182892021-03-02 Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora Borowik, Piotr Adamowicz, Leszek Tarakowski, Rafał Wacławik, Przemysław Oszako, Tomasz Ślusarski, Sławomir Tkaczyk, Miłosz Sensors (Basel) Article Compared with traditional gas chromatography–mass spectrometry techniques, electronic noses are non-invasive and can be a rapid, cost-effective option for several applications. This paper presents comparative studies of differentiation between odors emitted by two forest pathogens: Pythium and Phytophthora, measured by a low-cost electronic nose. The electronic nose applies six non-specific Figaro Inc. metal oxide sensors. Various features describing shapes of the measurement curves of sensors’ response to the odors’ exposure were extracted and used for building the classification models. As a machine learning algorithm for classification, we use the Support Vector Machine (SVM) method and various measures to assess classification models’ performance. Differentiation between Phytophthora and Pythium species has an important practical aspect allowing forest practitioners to take appropriate plant protection. We demonstrate the possibility to recognize and differentiate between the two mentioned species with acceptable accuracy by our low-cost electronic nose. MDPI 2021-02-13 /pmc/articles/PMC7918289/ /pubmed/33668511 http://dx.doi.org/10.3390/s21041326 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Borowik, Piotr
Adamowicz, Leszek
Tarakowski, Rafał
Wacławik, Przemysław
Oszako, Tomasz
Ślusarski, Sławomir
Tkaczyk, Miłosz
Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora
title Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora
title_full Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora
title_fullStr Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora
title_full_unstemmed Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora
title_short Application of a Low-Cost Electronic Nose for Differentiation between Pathogenic Oomycetes Pythium intermedium and Phytophthora plurivora
title_sort application of a low-cost electronic nose for differentiation between pathogenic oomycetes pythium intermedium and phytophthora plurivora
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7918289/
https://www.ncbi.nlm.nih.gov/pubmed/33668511
http://dx.doi.org/10.3390/s21041326
work_keys_str_mv AT borowikpiotr applicationofalowcostelectronicnosefordifferentiationbetweenpathogenicoomycetespythiumintermediumandphytophthoraplurivora
AT adamowiczleszek applicationofalowcostelectronicnosefordifferentiationbetweenpathogenicoomycetespythiumintermediumandphytophthoraplurivora
AT tarakowskirafał applicationofalowcostelectronicnosefordifferentiationbetweenpathogenicoomycetespythiumintermediumandphytophthoraplurivora
AT wacławikprzemysław applicationofalowcostelectronicnosefordifferentiationbetweenpathogenicoomycetespythiumintermediumandphytophthoraplurivora
AT oszakotomasz applicationofalowcostelectronicnosefordifferentiationbetweenpathogenicoomycetespythiumintermediumandphytophthoraplurivora
AT slusarskisławomir applicationofalowcostelectronicnosefordifferentiationbetweenpathogenicoomycetespythiumintermediumandphytophthoraplurivora
AT tkaczykmiłosz applicationofalowcostelectronicnosefordifferentiationbetweenpathogenicoomycetespythiumintermediumandphytophthoraplurivora