Cargando…

Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample

Whole-directional scanning methodology is required to observe distinctive features of an entire physical structure with a three dimensional (3D) visualization. However, the implementation of whole-directional scanning is challenging for conventional optical coherence tomography (OCT), which scans a...

Descripción completa

Detalles Bibliográficos
Autores principales: Saleah, Sm Abu, Seong, Daewoon, Han, Sangyeob, Wijesinghe, Ruchire Eranga, Ravichandran, Naresh Kumar, Jeon, Mansik, Kim, Jeehyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7918791/
https://www.ncbi.nlm.nih.gov/pubmed/33670358
http://dx.doi.org/10.3390/s21041305
_version_ 1783658005313617920
author Saleah, Sm Abu
Seong, Daewoon
Han, Sangyeob
Wijesinghe, Ruchire Eranga
Ravichandran, Naresh Kumar
Jeon, Mansik
Kim, Jeehyun
author_facet Saleah, Sm Abu
Seong, Daewoon
Han, Sangyeob
Wijesinghe, Ruchire Eranga
Ravichandran, Naresh Kumar
Jeon, Mansik
Kim, Jeehyun
author_sort Saleah, Sm Abu
collection PubMed
description Whole-directional scanning methodology is required to observe distinctive features of an entire physical structure with a three dimensional (3D) visualization. However, the implementation of whole-directional scanning is challenging for conventional optical coherence tomography (OCT), which scans a limited portion of the sample by utilizing unidirectional and bidirectional scanning methods. Therefore, in this paper an integrated quad-scanner (QS) strategy-based OCT method was implemented to obtain the whole-directional volumetry of a sample by employing four scanning arms installed around the sample. The simultaneous and sequential image acquisition capabilities are the conceptual key points of the proposed QS-OCT method, and were implemented using four precisely aligned scanning arms and applied in a complementary way according to the experimental criteria. To assess the feasibility of obtaining whole-directional morphological structures, a roll of Scotch tape, an ex vivo mouse heart, and kidney specimens were imaged and independently obtained tissue images at different directions were delicately merged to compose the 3D volume data set. The results revealed the potential merits of QS-OCT-based whole-directional imaging, which can be a favorable inspection method for various discoveries that require the dynamic coordinates of the whole physical structure.
format Online
Article
Text
id pubmed-7918791
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79187912021-03-02 Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample Saleah, Sm Abu Seong, Daewoon Han, Sangyeob Wijesinghe, Ruchire Eranga Ravichandran, Naresh Kumar Jeon, Mansik Kim, Jeehyun Sensors (Basel) Communication Whole-directional scanning methodology is required to observe distinctive features of an entire physical structure with a three dimensional (3D) visualization. However, the implementation of whole-directional scanning is challenging for conventional optical coherence tomography (OCT), which scans a limited portion of the sample by utilizing unidirectional and bidirectional scanning methods. Therefore, in this paper an integrated quad-scanner (QS) strategy-based OCT method was implemented to obtain the whole-directional volumetry of a sample by employing four scanning arms installed around the sample. The simultaneous and sequential image acquisition capabilities are the conceptual key points of the proposed QS-OCT method, and were implemented using four precisely aligned scanning arms and applied in a complementary way according to the experimental criteria. To assess the feasibility of obtaining whole-directional morphological structures, a roll of Scotch tape, an ex vivo mouse heart, and kidney specimens were imaged and independently obtained tissue images at different directions were delicately merged to compose the 3D volume data set. The results revealed the potential merits of QS-OCT-based whole-directional imaging, which can be a favorable inspection method for various discoveries that require the dynamic coordinates of the whole physical structure. MDPI 2021-02-11 /pmc/articles/PMC7918791/ /pubmed/33670358 http://dx.doi.org/10.3390/s21041305 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Saleah, Sm Abu
Seong, Daewoon
Han, Sangyeob
Wijesinghe, Ruchire Eranga
Ravichandran, Naresh Kumar
Jeon, Mansik
Kim, Jeehyun
Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample
title Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample
title_full Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample
title_fullStr Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample
title_full_unstemmed Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample
title_short Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample
title_sort integrated quad-scanner strategy-based optical coherence tomography for the whole-directional volumetric imaging of a sample
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7918791/
https://www.ncbi.nlm.nih.gov/pubmed/33670358
http://dx.doi.org/10.3390/s21041305
work_keys_str_mv AT saleahsmabu integratedquadscannerstrategybasedopticalcoherencetomographyforthewholedirectionalvolumetricimagingofasample
AT seongdaewoon integratedquadscannerstrategybasedopticalcoherencetomographyforthewholedirectionalvolumetricimagingofasample
AT hansangyeob integratedquadscannerstrategybasedopticalcoherencetomographyforthewholedirectionalvolumetricimagingofasample
AT wijesingheruchireeranga integratedquadscannerstrategybasedopticalcoherencetomographyforthewholedirectionalvolumetricimagingofasample
AT ravichandrannareshkumar integratedquadscannerstrategybasedopticalcoherencetomographyforthewholedirectionalvolumetricimagingofasample
AT jeonmansik integratedquadscannerstrategybasedopticalcoherencetomographyforthewholedirectionalvolumetricimagingofasample
AT kimjeehyun integratedquadscannerstrategybasedopticalcoherencetomographyforthewholedirectionalvolumetricimagingofasample