Cargando…
Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx)
Hemoptysis could be a life-threatening event, especially when the bleeding originates from the arterial pulmonary circulation. The main cause of this type of bleeding is pulmonary artery pseudoaneurysm (PAP), which can be managed by surgical, medical or minimally invasive techniques. This study repo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7921184/ https://www.ncbi.nlm.nih.gov/pubmed/33717384 http://dx.doi.org/10.1016/j.radcr.2021.02.029 |
_version_ | 1783658425743310848 |
---|---|
author | Lutz, Noémie Grange, Sylvain Sanson, Christian Grange, Rémi |
author_facet | Lutz, Noémie Grange, Sylvain Sanson, Christian Grange, Rémi |
author_sort | Lutz, Noémie |
collection | PubMed |
description | Hemoptysis could be a life-threatening event, especially when the bleeding originates from the arterial pulmonary circulation. The main cause of this type of bleeding is pulmonary artery pseudoaneurysm (PAP), which can be managed by surgical, medical or minimally invasive techniques. This study reports the case of massive hemoptysis in a 75-year-old male patient, with a former history of lobectomy. The initial CT scan showed a giant PAP from a branch of the right middle lobar pulmonary artery, within the right lower lobectomy cavity. An endovascular approach was decided. Subsequently, the feeding artery of the PAP was embolized with detachable coils. The control CT scan showed a persistent opacification of the PAP. The embolization was then completed by injection of Onyx within coils packing, with a complete thrombose of the PAP on control CT scan. This report confirms the safety and efficacy profile of an endovascular approach to treat giant PAP, using a combination of coils and Onyx. |
format | Online Article Text |
id | pubmed-7921184 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-79211842021-03-12 Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx) Lutz, Noémie Grange, Sylvain Sanson, Christian Grange, Rémi Radiol Case Rep Case Report Hemoptysis could be a life-threatening event, especially when the bleeding originates from the arterial pulmonary circulation. The main cause of this type of bleeding is pulmonary artery pseudoaneurysm (PAP), which can be managed by surgical, medical or minimally invasive techniques. This study reports the case of massive hemoptysis in a 75-year-old male patient, with a former history of lobectomy. The initial CT scan showed a giant PAP from a branch of the right middle lobar pulmonary artery, within the right lower lobectomy cavity. An endovascular approach was decided. Subsequently, the feeding artery of the PAP was embolized with detachable coils. The control CT scan showed a persistent opacification of the PAP. The embolization was then completed by injection of Onyx within coils packing, with a complete thrombose of the PAP on control CT scan. This report confirms the safety and efficacy profile of an endovascular approach to treat giant PAP, using a combination of coils and Onyx. Elsevier 2021-02-24 /pmc/articles/PMC7921184/ /pubmed/33717384 http://dx.doi.org/10.1016/j.radcr.2021.02.029 Text en © 2021 The Authors. Published by Elsevier Inc. on behalf of University of Washington. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case Report Lutz, Noémie Grange, Sylvain Sanson, Christian Grange, Rémi Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx) |
title | Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx) |
title_full | Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx) |
title_fullStr | Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx) |
title_full_unstemmed | Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx) |
title_short | Successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (Onyx) |
title_sort | successful embolization of giant pulmonary artery pseudoaneurysm using coils and ethylene vinyl alcohol copolymer (onyx) |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7921184/ https://www.ncbi.nlm.nih.gov/pubmed/33717384 http://dx.doi.org/10.1016/j.radcr.2021.02.029 |
work_keys_str_mv | AT lutznoemie successfulembolizationofgiantpulmonaryarterypseudoaneurysmusingcoilsandethylenevinylalcoholcopolymeronyx AT grangesylvain successfulembolizationofgiantpulmonaryarterypseudoaneurysmusingcoilsandethylenevinylalcoholcopolymeronyx AT sansonchristian successfulembolizationofgiantpulmonaryarterypseudoaneurysmusingcoilsandethylenevinylalcoholcopolymeronyx AT grangeremi successfulembolizationofgiantpulmonaryarterypseudoaneurysmusingcoilsandethylenevinylalcoholcopolymeronyx |