Bilateral Mechanically-Assisted Crevice Corrosion Resulting in Femoral Stem-Head Dissociation in Metal-on-Polyethylene Total Hip Arthroplasty
There are emerging reports of complications related to corrosion in modular femoral components. We report a unique case describing an 83-year-old man with bilateral mechanically-assisted crevice corrosion in hip replacements performed 10 years previously, by the same surgeon using the same size 3 Ac...
Autores principales: | McAleese, Timothy, Feeley, Iain, Hughes, Andrew, Sheehan, Eoin, Merghani, Khalid, Niall, Dorothy |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7921711/ https://www.ncbi.nlm.nih.gov/pubmed/33718553 http://dx.doi.org/10.1016/j.artd.2020.12.018 |
Ejemplares similares
-
A case of bilateral hip mechanically assisted crevice corrosion after staged total hip arthroplasty
por: Herndon, Carl L., et al.
Publicado: (2018) -
Challenges faced by orthopaedic trainees during the Covid-19 pandemic – An Irish perspective
por: Clesham, Kevin, et al.
Publicado: (2021) -
Injuries associated with arm wrestling: A narrative review
por: Moloney, Darren Patrick, et al.
Publicado: (2021) -
A Portable Hip Arthroscopy Simulator Demonstrates Good Face and Content Validity with Incomplete Construct Validity
por: Feeley, Aoife, et al.
Publicado: (2021) -
Mechanically Assisted Crevice Corrosion in a Metal-on-Polyethylene Total Hip Presenting With Lower Extremity Vascular Compromise
por: Zink, Thomas M., et al.
Publicado: (2020)