Cargando…

A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples

This research reports a portable immunochip, based on quartz crystal microbalance (QCM) for label-free, low-cost qualitative detection of zearalenone (ZEN) in food samples. The experimental parameters in the functionalization and working process were evaluated in detail, in order to achieve a high a...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Shengmiao, Liu, Xinyu, Pan, Qianwen, Dai, Zhihan, Pan, Mingfei, Wang, Shuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7922548/
https://www.ncbi.nlm.nih.gov/pubmed/33669533
http://dx.doi.org/10.3390/bios11020053
_version_ 1783658715872755712
author Liu, Shengmiao
Liu, Xinyu
Pan, Qianwen
Dai, Zhihan
Pan, Mingfei
Wang, Shuo
author_facet Liu, Shengmiao
Liu, Xinyu
Pan, Qianwen
Dai, Zhihan
Pan, Mingfei
Wang, Shuo
author_sort Liu, Shengmiao
collection PubMed
description This research reports a portable immunochip, based on quartz crystal microbalance (QCM) for label-free, low-cost qualitative detection of zearalenone (ZEN) in food samples. The experimental parameters in the functionalization and working process were evaluated in detail, in order to achieve a high accuracy and sensitivity. Under optimal conditions, the ZEN concentration at an inhibition ratio of 50% and 15% of the proposed QCM immunochip achieved 3.41 µg L(−1) and 0.37 µg L(−1), respectively. This portable QCM immunochip also exhibited high specificity, no obvious cross-reaction to five structural analogs of ZEN, and showed other mycotoxins. It could finish the whole qualitative measurement within 30 min, showed good stability during the processes of preparation (SD < 5%, n = 9), storage (frequency response >90%, in PBS at 4 °C for 15 days), and application (frequency response >90% after being reused 6 times). The developed QCM immunochip obtained accurate and repeatable recovery results in ZEN analysis in the chosen food samples (corn, wheat flour, soy sauce, and milk), which had a high correlation (R(2) = 0.9844) with that achieved by the HPLC–MS/MS method. In short, this work developed a portable, stable, and reproducible QCM immunochip that could be used for rapid, low-cost, and sensitively measurement of ZEN content in real food samples.
format Online
Article
Text
id pubmed-7922548
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79225482021-03-03 A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples Liu, Shengmiao Liu, Xinyu Pan, Qianwen Dai, Zhihan Pan, Mingfei Wang, Shuo Biosensors (Basel) Article This research reports a portable immunochip, based on quartz crystal microbalance (QCM) for label-free, low-cost qualitative detection of zearalenone (ZEN) in food samples. The experimental parameters in the functionalization and working process were evaluated in detail, in order to achieve a high accuracy and sensitivity. Under optimal conditions, the ZEN concentration at an inhibition ratio of 50% and 15% of the proposed QCM immunochip achieved 3.41 µg L(−1) and 0.37 µg L(−1), respectively. This portable QCM immunochip also exhibited high specificity, no obvious cross-reaction to five structural analogs of ZEN, and showed other mycotoxins. It could finish the whole qualitative measurement within 30 min, showed good stability during the processes of preparation (SD < 5%, n = 9), storage (frequency response >90%, in PBS at 4 °C for 15 days), and application (frequency response >90% after being reused 6 times). The developed QCM immunochip obtained accurate and repeatable recovery results in ZEN analysis in the chosen food samples (corn, wheat flour, soy sauce, and milk), which had a high correlation (R(2) = 0.9844) with that achieved by the HPLC–MS/MS method. In short, this work developed a portable, stable, and reproducible QCM immunochip that could be used for rapid, low-cost, and sensitively measurement of ZEN content in real food samples. MDPI 2021-02-19 /pmc/articles/PMC7922548/ /pubmed/33669533 http://dx.doi.org/10.3390/bios11020053 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Shengmiao
Liu, Xinyu
Pan, Qianwen
Dai, Zhihan
Pan, Mingfei
Wang, Shuo
A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples
title A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples
title_full A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples
title_fullStr A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples
title_full_unstemmed A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples
title_short A Portable, Label-Free, Reproducible Quartz Crystal Microbalance Immunochip for the Detection of Zearalenone in Food Samples
title_sort portable, label-free, reproducible quartz crystal microbalance immunochip for the detection of zearalenone in food samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7922548/
https://www.ncbi.nlm.nih.gov/pubmed/33669533
http://dx.doi.org/10.3390/bios11020053
work_keys_str_mv AT liushengmiao aportablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT liuxinyu aportablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT panqianwen aportablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT daizhihan aportablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT panmingfei aportablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT wangshuo aportablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT liushengmiao portablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT liuxinyu portablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT panqianwen portablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT daizhihan portablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT panmingfei portablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples
AT wangshuo portablelabelfreereproduciblequartzcrystalmicrobalanceimmunochipforthedetectionofzearalenoneinfoodsamples