Cargando…

Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process

In the injection molding field, the flow of plastic material is one of the most important issues, especially regarding the ability of melted plastic to fill the thin walls of products. To improve the melt flow length, a high mold temperature was applied with pre-heating of the cavity surface. In thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Giang, Nguyen Truong, Minh, Pham Son, Son, Tran Anh, Uyen, Tran Minh The, Nguyen, Thanh-Hai, Dang, Hung-Son
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7922572/
https://www.ncbi.nlm.nih.gov/pubmed/33670695
http://dx.doi.org/10.3390/ma14040965
_version_ 1783658721802452992
author Giang, Nguyen Truong
Minh, Pham Son
Son, Tran Anh
Uyen, Tran Minh The
Nguyen, Thanh-Hai
Dang, Hung-Son
author_facet Giang, Nguyen Truong
Minh, Pham Son
Son, Tran Anh
Uyen, Tran Minh The
Nguyen, Thanh-Hai
Dang, Hung-Son
author_sort Giang, Nguyen Truong
collection PubMed
description In the injection molding field, the flow of plastic material is one of the most important issues, especially regarding the ability of melted plastic to fill the thin walls of products. To improve the melt flow length, a high mold temperature was applied with pre-heating of the cavity surface. In this paper, we present our research on the injection molding process with pre-heating by external gas-assisted mold temperature control. After this, we observed an improvement in the melt flow length into thin-walled products due to the high mold temperature during the filling step. In addition, to develop the heating efficiency, a flow focusing device (FFD) was applied and verified. The simulations and experiments were carried out within an air temperature of 400 °C and heating time of 20 s to investigate a flow focusing device to assist with external gas-assisted mold temperature control (Ex-GMTC), with the application of various FFD types for the temperature distribution of the insert plate. The heating process was applied for a simple insert model with dimensions of 50 mm × 50 mm × 2 mm, in order to verify the influence of the FFD geometry on the heating result. After that, Ex-GMTC with the assistance of FFD was carried out for a mold-reading process, and the FFD influence was estimated by the mold heating result and the improvement of the melt flow length using acrylonitrile butadiene styrene (ABS). The results show that the air sprue gap (h) significantly affects the temperature of the insert and an air sprue gap of 3 mm gives the best heating rate, with the highest temperature being 321.2 °C. Likewise, the actual results show that the height of the flow focusing device (V) also influences the temperature of the insert plate and that a 5 mm high FFD gives the best results with a maximum temperature of 332.3 °C. Moreover, the heating efficiency when using FFD is always higher than without FFD. After examining the effect of FFD, its application was considered, in order to improve the melt flow length in injection molding, which increased from 38.6 to 170 mm, while the balance of the melt filling was also clearly improved.
format Online
Article
Text
id pubmed-7922572
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79225722021-03-03 Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process Giang, Nguyen Truong Minh, Pham Son Son, Tran Anh Uyen, Tran Minh The Nguyen, Thanh-Hai Dang, Hung-Son Materials (Basel) Article In the injection molding field, the flow of plastic material is one of the most important issues, especially regarding the ability of melted plastic to fill the thin walls of products. To improve the melt flow length, a high mold temperature was applied with pre-heating of the cavity surface. In this paper, we present our research on the injection molding process with pre-heating by external gas-assisted mold temperature control. After this, we observed an improvement in the melt flow length into thin-walled products due to the high mold temperature during the filling step. In addition, to develop the heating efficiency, a flow focusing device (FFD) was applied and verified. The simulations and experiments were carried out within an air temperature of 400 °C and heating time of 20 s to investigate a flow focusing device to assist with external gas-assisted mold temperature control (Ex-GMTC), with the application of various FFD types for the temperature distribution of the insert plate. The heating process was applied for a simple insert model with dimensions of 50 mm × 50 mm × 2 mm, in order to verify the influence of the FFD geometry on the heating result. After that, Ex-GMTC with the assistance of FFD was carried out for a mold-reading process, and the FFD influence was estimated by the mold heating result and the improvement of the melt flow length using acrylonitrile butadiene styrene (ABS). The results show that the air sprue gap (h) significantly affects the temperature of the insert and an air sprue gap of 3 mm gives the best heating rate, with the highest temperature being 321.2 °C. Likewise, the actual results show that the height of the flow focusing device (V) also influences the temperature of the insert plate and that a 5 mm high FFD gives the best results with a maximum temperature of 332.3 °C. Moreover, the heating efficiency when using FFD is always higher than without FFD. After examining the effect of FFD, its application was considered, in order to improve the melt flow length in injection molding, which increased from 38.6 to 170 mm, while the balance of the melt filling was also clearly improved. MDPI 2021-02-18 /pmc/articles/PMC7922572/ /pubmed/33670695 http://dx.doi.org/10.3390/ma14040965 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Giang, Nguyen Truong
Minh, Pham Son
Son, Tran Anh
Uyen, Tran Minh The
Nguyen, Thanh-Hai
Dang, Hung-Son
Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process
title Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process
title_full Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process
title_fullStr Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process
title_full_unstemmed Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process
title_short Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process
title_sort study on external gas-assisted mold temperature control with the assistance of a flow focusing device in the injection molding process
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7922572/
https://www.ncbi.nlm.nih.gov/pubmed/33670695
http://dx.doi.org/10.3390/ma14040965
work_keys_str_mv AT giangnguyentruong studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess
AT minhphamson studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess
AT sontrananh studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess
AT uyentranminhthe studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess
AT nguyenthanhhai studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess
AT danghungson studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess