Cargando…
Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process
In the injection molding field, the flow of plastic material is one of the most important issues, especially regarding the ability of melted plastic to fill the thin walls of products. To improve the melt flow length, a high mold temperature was applied with pre-heating of the cavity surface. In thi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7922572/ https://www.ncbi.nlm.nih.gov/pubmed/33670695 http://dx.doi.org/10.3390/ma14040965 |
_version_ | 1783658721802452992 |
---|---|
author | Giang, Nguyen Truong Minh, Pham Son Son, Tran Anh Uyen, Tran Minh The Nguyen, Thanh-Hai Dang, Hung-Son |
author_facet | Giang, Nguyen Truong Minh, Pham Son Son, Tran Anh Uyen, Tran Minh The Nguyen, Thanh-Hai Dang, Hung-Son |
author_sort | Giang, Nguyen Truong |
collection | PubMed |
description | In the injection molding field, the flow of plastic material is one of the most important issues, especially regarding the ability of melted plastic to fill the thin walls of products. To improve the melt flow length, a high mold temperature was applied with pre-heating of the cavity surface. In this paper, we present our research on the injection molding process with pre-heating by external gas-assisted mold temperature control. After this, we observed an improvement in the melt flow length into thin-walled products due to the high mold temperature during the filling step. In addition, to develop the heating efficiency, a flow focusing device (FFD) was applied and verified. The simulations and experiments were carried out within an air temperature of 400 °C and heating time of 20 s to investigate a flow focusing device to assist with external gas-assisted mold temperature control (Ex-GMTC), with the application of various FFD types for the temperature distribution of the insert plate. The heating process was applied for a simple insert model with dimensions of 50 mm × 50 mm × 2 mm, in order to verify the influence of the FFD geometry on the heating result. After that, Ex-GMTC with the assistance of FFD was carried out for a mold-reading process, and the FFD influence was estimated by the mold heating result and the improvement of the melt flow length using acrylonitrile butadiene styrene (ABS). The results show that the air sprue gap (h) significantly affects the temperature of the insert and an air sprue gap of 3 mm gives the best heating rate, with the highest temperature being 321.2 °C. Likewise, the actual results show that the height of the flow focusing device (V) also influences the temperature of the insert plate and that a 5 mm high FFD gives the best results with a maximum temperature of 332.3 °C. Moreover, the heating efficiency when using FFD is always higher than without FFD. After examining the effect of FFD, its application was considered, in order to improve the melt flow length in injection molding, which increased from 38.6 to 170 mm, while the balance of the melt filling was also clearly improved. |
format | Online Article Text |
id | pubmed-7922572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79225722021-03-03 Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process Giang, Nguyen Truong Minh, Pham Son Son, Tran Anh Uyen, Tran Minh The Nguyen, Thanh-Hai Dang, Hung-Son Materials (Basel) Article In the injection molding field, the flow of plastic material is one of the most important issues, especially regarding the ability of melted plastic to fill the thin walls of products. To improve the melt flow length, a high mold temperature was applied with pre-heating of the cavity surface. In this paper, we present our research on the injection molding process with pre-heating by external gas-assisted mold temperature control. After this, we observed an improvement in the melt flow length into thin-walled products due to the high mold temperature during the filling step. In addition, to develop the heating efficiency, a flow focusing device (FFD) was applied and verified. The simulations and experiments were carried out within an air temperature of 400 °C and heating time of 20 s to investigate a flow focusing device to assist with external gas-assisted mold temperature control (Ex-GMTC), with the application of various FFD types for the temperature distribution of the insert plate. The heating process was applied for a simple insert model with dimensions of 50 mm × 50 mm × 2 mm, in order to verify the influence of the FFD geometry on the heating result. After that, Ex-GMTC with the assistance of FFD was carried out for a mold-reading process, and the FFD influence was estimated by the mold heating result and the improvement of the melt flow length using acrylonitrile butadiene styrene (ABS). The results show that the air sprue gap (h) significantly affects the temperature of the insert and an air sprue gap of 3 mm gives the best heating rate, with the highest temperature being 321.2 °C. Likewise, the actual results show that the height of the flow focusing device (V) also influences the temperature of the insert plate and that a 5 mm high FFD gives the best results with a maximum temperature of 332.3 °C. Moreover, the heating efficiency when using FFD is always higher than without FFD. After examining the effect of FFD, its application was considered, in order to improve the melt flow length in injection molding, which increased from 38.6 to 170 mm, while the balance of the melt filling was also clearly improved. MDPI 2021-02-18 /pmc/articles/PMC7922572/ /pubmed/33670695 http://dx.doi.org/10.3390/ma14040965 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Giang, Nguyen Truong Minh, Pham Son Son, Tran Anh Uyen, Tran Minh The Nguyen, Thanh-Hai Dang, Hung-Son Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process |
title | Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process |
title_full | Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process |
title_fullStr | Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process |
title_full_unstemmed | Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process |
title_short | Study on External Gas-Assisted Mold Temperature Control with the Assistance of a Flow Focusing Device in the Injection Molding Process |
title_sort | study on external gas-assisted mold temperature control with the assistance of a flow focusing device in the injection molding process |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7922572/ https://www.ncbi.nlm.nih.gov/pubmed/33670695 http://dx.doi.org/10.3390/ma14040965 |
work_keys_str_mv | AT giangnguyentruong studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess AT minhphamson studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess AT sontrananh studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess AT uyentranminhthe studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess AT nguyenthanhhai studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess AT danghungson studyonexternalgasassistedmoldtemperaturecontrolwiththeassistanceofaflowfocusingdeviceintheinjectionmoldingprocess |