Cargando…

Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography

Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advanta...

Descripción completa

Detalles Bibliográficos
Autores principales: Dahm, Valerie, Schwarz–Nemec, Ursula, Auinger, Alice B., Arnoldner, Michael A., Kaider, Alexandra, Riss, Dominik, Czerny, Christian, Arnoldner, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7923124/
https://www.ncbi.nlm.nih.gov/pubmed/33671447
http://dx.doi.org/10.3390/life11020156
_version_ 1783658842307952640
author Dahm, Valerie
Schwarz–Nemec, Ursula
Auinger, Alice B.
Arnoldner, Michael A.
Kaider, Alexandra
Riss, Dominik
Czerny, Christian
Arnoldner, Christoph
author_facet Dahm, Valerie
Schwarz–Nemec, Ursula
Auinger, Alice B.
Arnoldner, Michael A.
Kaider, Alexandra
Riss, Dominik
Czerny, Christian
Arnoldner, Christoph
author_sort Dahm, Valerie
collection PubMed
description Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum–fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of −0.17 mm (±0.20). Platinum–fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum–fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position.
format Online
Article
Text
id pubmed-7923124
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79231242021-03-03 Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography Dahm, Valerie Schwarz–Nemec, Ursula Auinger, Alice B. Arnoldner, Michael A. Kaider, Alexandra Riss, Dominik Czerny, Christian Arnoldner, Christoph Life (Basel) Article Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum–fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of −0.17 mm (±0.20). Platinum–fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum–fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position. MDPI 2021-02-17 /pmc/articles/PMC7923124/ /pubmed/33671447 http://dx.doi.org/10.3390/life11020156 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dahm, Valerie
Schwarz–Nemec, Ursula
Auinger, Alice B.
Arnoldner, Michael A.
Kaider, Alexandra
Riss, Dominik
Czerny, Christian
Arnoldner, Christoph
Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
title Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
title_full Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
title_fullStr Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
title_full_unstemmed Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
title_short Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
title_sort titanium and platinum–fluoroplastic stapes prostheses visualization on cone beam computed tomography and high-resolution computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7923124/
https://www.ncbi.nlm.nih.gov/pubmed/33671447
http://dx.doi.org/10.3390/life11020156
work_keys_str_mv AT dahmvalerie titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography
AT schwarznemecursula titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography
AT auingeraliceb titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography
AT arnoldnermichaela titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography
AT kaideralexandra titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography
AT rissdominik titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography
AT czernychristian titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography
AT arnoldnerchristoph titaniumandplatinumfluoroplasticstapesprosthesesvisualizationonconebeamcomputedtomographyandhighresolutioncomputedtomography