Cargando…
Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring
(1) Background: Portable NIR spectrometers gain more and more ground in the field of Process Analytical Technology due to the easy on-site flexibility and interfacing versatility. These advantages that originate from the instrument miniaturization, also come with a downside with respect to performan...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924328/ https://www.ncbi.nlm.nih.gov/pubmed/33672675 http://dx.doi.org/10.3390/molecules26041129 |
_version_ | 1783659065255133184 |
---|---|
author | Casian, Tibor Gavan, Alexandru Iurian, Sonia Porfire, Alina Toma, Valentin Stiufiuc, Rares Tomuta, Ioan |
author_facet | Casian, Tibor Gavan, Alexandru Iurian, Sonia Porfire, Alina Toma, Valentin Stiufiuc, Rares Tomuta, Ioan |
author_sort | Casian, Tibor |
collection | PubMed |
description | (1) Background: Portable NIR spectrometers gain more and more ground in the field of Process Analytical Technology due to the easy on-site flexibility and interfacing versatility. These advantages that originate from the instrument miniaturization, also come with a downside with respect to performance compared to benchtop devices. The objective of this work was to evaluate the performance of MicroNIR in a pharmaceutical powder blend application, having three active ingredients and 5 excipients. (2) Methods: Spectral data was recorded in reflectance mode using static and dynamic acquisition, on calibration set samples developed using an experimental design. (3) Results: The developed method accurately predicted the content uniformity of these complex mixtures, moreover it was validated in the entire calibration range using ±10% acceptance limits. With respect to at-line prediction, the method presented lower performance compared to a previously studied benchtop spectrometer. Regarding the in-line monitoring of the blending process, it was shown that the spectral variability-induced by dynamic acquisition could be efficiently managed using spectral pre-processing. (4) Conclusions: The in-line process monitoring resulted in accurate concentration profiles, highlighting differences in the mixing behaviour of the investigated ingredients. For the low dose component homogeneity was not reached due to an inefficient dispersive mixing. |
format | Online Article Text |
id | pubmed-7924328 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79243282021-03-03 Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring Casian, Tibor Gavan, Alexandru Iurian, Sonia Porfire, Alina Toma, Valentin Stiufiuc, Rares Tomuta, Ioan Molecules Article (1) Background: Portable NIR spectrometers gain more and more ground in the field of Process Analytical Technology due to the easy on-site flexibility and interfacing versatility. These advantages that originate from the instrument miniaturization, also come with a downside with respect to performance compared to benchtop devices. The objective of this work was to evaluate the performance of MicroNIR in a pharmaceutical powder blend application, having three active ingredients and 5 excipients. (2) Methods: Spectral data was recorded in reflectance mode using static and dynamic acquisition, on calibration set samples developed using an experimental design. (3) Results: The developed method accurately predicted the content uniformity of these complex mixtures, moreover it was validated in the entire calibration range using ±10% acceptance limits. With respect to at-line prediction, the method presented lower performance compared to a previously studied benchtop spectrometer. Regarding the in-line monitoring of the blending process, it was shown that the spectral variability-induced by dynamic acquisition could be efficiently managed using spectral pre-processing. (4) Conclusions: The in-line process monitoring resulted in accurate concentration profiles, highlighting differences in the mixing behaviour of the investigated ingredients. For the low dose component homogeneity was not reached due to an inefficient dispersive mixing. MDPI 2021-02-20 /pmc/articles/PMC7924328/ /pubmed/33672675 http://dx.doi.org/10.3390/molecules26041129 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Casian, Tibor Gavan, Alexandru Iurian, Sonia Porfire, Alina Toma, Valentin Stiufiuc, Rares Tomuta, Ioan Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring |
title | Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring |
title_full | Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring |
title_fullStr | Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring |
title_full_unstemmed | Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring |
title_short | Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring |
title_sort | testing the limits of a portable nir spectrometer: content uniformity of complex powder mixtures followed by calibration transfer for in-line blend monitoring |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924328/ https://www.ncbi.nlm.nih.gov/pubmed/33672675 http://dx.doi.org/10.3390/molecules26041129 |
work_keys_str_mv | AT casiantibor testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring AT gavanalexandru testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring AT iuriansonia testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring AT porfirealina testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring AT tomavalentin testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring AT stiufiucrares testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring AT tomutaioan testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring |