Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring

(1) Background: Portable NIR spectrometers gain more and more ground in the field of Process Analytical Technology due to the easy on-site flexibility and interfacing versatility. These advantages that originate from the instrument miniaturization, also come with a downside with respect to performan...

Descripción completa

Detalles Bibliográficos
Autores principales: Casian, Tibor, Gavan, Alexandru, Iurian, Sonia, Porfire, Alina, Toma, Valentin, Stiufiuc, Rares, Tomuta, Ioan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924328/
https://www.ncbi.nlm.nih.gov/pubmed/33672675
http://dx.doi.org/10.3390/molecules26041129
_version_ 1783659065255133184
author Casian, Tibor
Gavan, Alexandru
Iurian, Sonia
Porfire, Alina
Toma, Valentin
Stiufiuc, Rares
Tomuta, Ioan
author_facet Casian, Tibor
Gavan, Alexandru
Iurian, Sonia
Porfire, Alina
Toma, Valentin
Stiufiuc, Rares
Tomuta, Ioan
author_sort Casian, Tibor
collection PubMed
description (1) Background: Portable NIR spectrometers gain more and more ground in the field of Process Analytical Technology due to the easy on-site flexibility and interfacing versatility. These advantages that originate from the instrument miniaturization, also come with a downside with respect to performance compared to benchtop devices. The objective of this work was to evaluate the performance of MicroNIR in a pharmaceutical powder blend application, having three active ingredients and 5 excipients. (2) Methods: Spectral data was recorded in reflectance mode using static and dynamic acquisition, on calibration set samples developed using an experimental design. (3) Results: The developed method accurately predicted the content uniformity of these complex mixtures, moreover it was validated in the entire calibration range using ±10% acceptance limits. With respect to at-line prediction, the method presented lower performance compared to a previously studied benchtop spectrometer. Regarding the in-line monitoring of the blending process, it was shown that the spectral variability-induced by dynamic acquisition could be efficiently managed using spectral pre-processing. (4) Conclusions: The in-line process monitoring resulted in accurate concentration profiles, highlighting differences in the mixing behaviour of the investigated ingredients. For the low dose component homogeneity was not reached due to an inefficient dispersive mixing.
format Online
Article
Text
id pubmed-7924328
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79243282021-03-03 Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring Casian, Tibor Gavan, Alexandru Iurian, Sonia Porfire, Alina Toma, Valentin Stiufiuc, Rares Tomuta, Ioan Molecules Article (1) Background: Portable NIR spectrometers gain more and more ground in the field of Process Analytical Technology due to the easy on-site flexibility and interfacing versatility. These advantages that originate from the instrument miniaturization, also come with a downside with respect to performance compared to benchtop devices. The objective of this work was to evaluate the performance of MicroNIR in a pharmaceutical powder blend application, having three active ingredients and 5 excipients. (2) Methods: Spectral data was recorded in reflectance mode using static and dynamic acquisition, on calibration set samples developed using an experimental design. (3) Results: The developed method accurately predicted the content uniformity of these complex mixtures, moreover it was validated in the entire calibration range using ±10% acceptance limits. With respect to at-line prediction, the method presented lower performance compared to a previously studied benchtop spectrometer. Regarding the in-line monitoring of the blending process, it was shown that the spectral variability-induced by dynamic acquisition could be efficiently managed using spectral pre-processing. (4) Conclusions: The in-line process monitoring resulted in accurate concentration profiles, highlighting differences in the mixing behaviour of the investigated ingredients. For the low dose component homogeneity was not reached due to an inefficient dispersive mixing. MDPI 2021-02-20 /pmc/articles/PMC7924328/ /pubmed/33672675 http://dx.doi.org/10.3390/molecules26041129 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Casian, Tibor
Gavan, Alexandru
Iurian, Sonia
Porfire, Alina
Toma, Valentin
Stiufiuc, Rares
Tomuta, Ioan
Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring
title Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring
title_full Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring
title_fullStr Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring
title_full_unstemmed Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring
title_short Testing the Limits of a Portable NIR Spectrometer: Content Uniformity of Complex Powder Mixtures Followed by Calibration Transfer for In-Line Blend Monitoring
title_sort testing the limits of a portable nir spectrometer: content uniformity of complex powder mixtures followed by calibration transfer for in-line blend monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924328/
https://www.ncbi.nlm.nih.gov/pubmed/33672675
http://dx.doi.org/10.3390/molecules26041129
work_keys_str_mv AT casiantibor testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring
AT gavanalexandru testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring
AT iuriansonia testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring
AT porfirealina testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring
AT tomavalentin testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring
AT stiufiucrares testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring
AT tomutaioan testingthelimitsofaportablenirspectrometercontentuniformityofcomplexpowdermixturesfollowedbycalibrationtransferforinlineblendmonitoring