Cargando…

Continuous positive airway pressure for respiratory support during COVID-19 pandemic: a frugal approach from bench to bedside

BACKGROUND: We describe a frugal approach (focusing on needs, performance, and costs) to manage a massive influx of COVID-19 patients with acute hypoxemic respiratory failure (AHRF) using the Boussignac valve protected by a filter (“Filter Frugal CPAP”, FF-CPAP) in and out the ICU. METHODS: (1) A be...

Descripción completa

Detalles Bibliográficos
Autores principales: Carteaux, Guillaume, Pons, Manuella, Morin, François, Tuffet, Samuel, Lesimple, Arnaud, Badat, Bilal, Haudebourg, Anne-Fleur, Perier, François, Deplante, Yvon, Guillaud, Constance, Schlemmer, Frédéric, Fois, Elena, Mongardon, Nicolas, Khellaf, Mehdi, Jaffal, Karim, Deguillard, Camille, Grimbert, Philippe, Huguet, Raphaëlle, Razazi, Keyvan, de Prost, Nicolas, Templier, François, Beloncle, François, Mercat, Alain, Brochard, Laurent, Audard, Vincent, Lim, Pascal, Richard, Jean-Christophe, Savary, Dominique, Mekontso Dessap, Armand
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924341/
https://www.ncbi.nlm.nih.gov/pubmed/33655452
http://dx.doi.org/10.1186/s13613-021-00828-2
Descripción
Sumario:BACKGROUND: We describe a frugal approach (focusing on needs, performance, and costs) to manage a massive influx of COVID-19 patients with acute hypoxemic respiratory failure (AHRF) using the Boussignac valve protected by a filter (“Filter Frugal CPAP”, FF-CPAP) in and out the ICU. METHODS: (1) A bench study measured the impact of two filters with different mechanical properties on CPAP performances, and pressures were also measured in patients. (2) Non-ICU healthcare staff working in COVID-19 intermediate care units were trained with a video tutorial posted on a massive open online course. (3) A clinical study assessed the feasibility and safety of using FF-CPAP to maintain oxygenation and manage patients out of the ICU during a massive outbreak. RESULTS: Bench assessments showed that adding a filter did not affect the effective pressure delivered to the patient. The resistive load induced by the filter variably increased the simulated patient’s work of breathing (6–34%) needed to sustain the tidal volume, depending on the filter’s resistance, respiratory mechanics and basal inspiratory effort. In patients, FF-CPAP achieved pressures similar to those obtained on the bench. The massive training tool provided precious information on the use of Boussignac FF-CPAP on COVID-19 patients. Then 85 COVID-19 patients with ICU admission criteria over a 1-month period were studied upon FF-CPAP initiation for AHRF. FF-CPAP significantly decreased respiratory rate and increased SpO(2). Thirty-six (43%) patients presented with respiratory indications for intubation prior to FF-CPAP initiation, and 13 (36%) of them improved without intubation. Overall, 31 patients (36%) improved with FF-CPAP alone and 17 patients (20%) did not require ICU admission. Patients with a respiratory rate > 32 breaths/min upon FF-CPAP initiation had a higher cumulative probability of intubation (p < 0.001 by log-rank test). CONCLUSION: Adding a filter to the Boussignac valve does not affect the delivered pressure but may variably increase the resistive load depending on the filter used. Clinical assessment suggests that FF-CPAP is a frugal solution to provide a ventilatory support and improve oxygenation to numerous patients suffering from AHRF in the context of a massive outbreak. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13613-021-00828-2.