Cargando…
Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection
Cardiac implantable electronic device (CIED) infections are a serious complication of both initial device implants and generator change procedures, and they are associated with a wide range of presentations. Reported rates of CIED infections vary widely from 0.1% to 19.9%, but it is estimated that t...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924889/ https://www.ncbi.nlm.nih.gov/pubmed/33665058 http://dx.doi.org/10.7759/cureus.13037 |
_version_ | 1783659186373001216 |
---|---|
author | Buchanan, Emily Yoo, Dale |
author_facet | Buchanan, Emily Yoo, Dale |
author_sort | Buchanan, Emily |
collection | PubMed |
description | Cardiac implantable electronic device (CIED) infections are a serious complication of both initial device implants and generator change procedures, and they are associated with a wide range of presentations. Reported rates of CIED infections vary widely from 0.1% to 19.9%, but it is estimated that they occur in 0.5% of initial device implants and 1-7% of subsequent implants. It is widely accepted that the administration of local antibiotics within the pocket as well as extracellular matrices (ECMs) can be utilized to reduce the incidence of CIED infections. We describe a case where the use of an additional biological ECM scaffold sutured directly into the incision site was utilized in addition to a biological ECM pouch in order to reduce the risk of infection. We propose that biological ECM could be utilized to reinforce the incision site directly as well as ECM within the pocket to reduce the instances of CIED infections. Further investigation of the use of biological ECM to prevent infection is warranted and paramount to further decrease the number of complications associated with device implantation. |
format | Online Article Text |
id | pubmed-7924889 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-79248892021-03-03 Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection Buchanan, Emily Yoo, Dale Cureus Cardiac/Thoracic/Vascular Surgery Cardiac implantable electronic device (CIED) infections are a serious complication of both initial device implants and generator change procedures, and they are associated with a wide range of presentations. Reported rates of CIED infections vary widely from 0.1% to 19.9%, but it is estimated that they occur in 0.5% of initial device implants and 1-7% of subsequent implants. It is widely accepted that the administration of local antibiotics within the pocket as well as extracellular matrices (ECMs) can be utilized to reduce the incidence of CIED infections. We describe a case where the use of an additional biological ECM scaffold sutured directly into the incision site was utilized in addition to a biological ECM pouch in order to reduce the risk of infection. We propose that biological ECM could be utilized to reinforce the incision site directly as well as ECM within the pocket to reduce the instances of CIED infections. Further investigation of the use of biological ECM to prevent infection is warranted and paramount to further decrease the number of complications associated with device implantation. Cureus 2021-01-31 /pmc/articles/PMC7924889/ /pubmed/33665058 http://dx.doi.org/10.7759/cureus.13037 Text en Copyright © 2021, Buchanan et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiac/Thoracic/Vascular Surgery Buchanan, Emily Yoo, Dale Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection |
title | Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection |
title_full | Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection |
title_fullStr | Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection |
title_full_unstemmed | Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection |
title_short | Use of Biologic Extracellular Matrix in Two Ways to Reduce Cardiac Electronic Device Infection |
title_sort | use of biologic extracellular matrix in two ways to reduce cardiac electronic device infection |
topic | Cardiac/Thoracic/Vascular Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924889/ https://www.ncbi.nlm.nih.gov/pubmed/33665058 http://dx.doi.org/10.7759/cureus.13037 |
work_keys_str_mv | AT buchananemily useofbiologicextracellularmatrixintwowaystoreducecardiacelectronicdeviceinfection AT yoodale useofbiologicextracellularmatrixintwowaystoreducecardiacelectronicdeviceinfection |