Cargando…

Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population

PURPOSE: The aim of this study was to determine the correlation between the perimetric outcomes using a free application program of the iPad, 'Visual Fields Easy' (VFE), and Humphrey Visual Field Analyzer (HVFA), in normal as well as eyes with glaucomatous damage of varying severity. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Ichhpujani, Parul, Thakur, Sahil, Sahi, Roopjit K, Kumar, Suresh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7926121/
https://www.ncbi.nlm.nih.gov/pubmed/33323582
http://dx.doi.org/10.4103/ijo.IJO_1847_19
_version_ 1783659402410065920
author Ichhpujani, Parul
Thakur, Sahil
Sahi, Roopjit K
Kumar, Suresh
author_facet Ichhpujani, Parul
Thakur, Sahil
Sahi, Roopjit K
Kumar, Suresh
author_sort Ichhpujani, Parul
collection PubMed
description PURPOSE: The aim of this study was to determine the correlation between the perimetric outcomes using a free application program of the iPad, 'Visual Fields Easy' (VFE), and Humphrey Visual Field Analyzer (HVFA), in normal as well as eyes with glaucomatous damage of varying severity. METHODS: In this prospective, cross-sectional, observational pilot investigation, visual field testing was carried out in 210 eyes of 210 patients (60 Normal, 150 Glaucoma), using suprathreshold VFE application (Version 8) on the iPad and Standard White-on-White using HVFA. Severity of glaucoma was categorized using Hodapp-Anderson-Parrish criteria for visual field defects. The results of the VFE program were compared to the 24-2 SITA FAST HVFA. RESULTS: Data of 210 patients, 100 (47.6%) females, and 110 (52.4%) males, age ranging from 42 to 78 years, Mean 56.64 ± 10.67 years, was analyzed. The Spearman correlation coefficient showed a significant inverse relationship between missed points on the VFE app with MD (S = –0.783) and a parabolic relationship with PSD (S = 0.646) values obtained with the HVFA. As regards missed points, for mild glaucoma, missed points were 37.5, sensitivity was 77.8% and specificity was 52.6%; for moderate glaucoma, missed points were 33.5, sensitivity was 90% and specificity was 48% while for severe glaucoma, missed points were 23, sensitivity was 97% and specificity was 70%. AROC for eyes with mild glaucoma versus normal was 0.419 (95% CI: 0.343-0.495), moderate glaucoma versus normal was 0.705 (95% CI: 0.630-0.780) and severe glaucoma versus normal was 0.857 (95% CI: 0.806-0.908). CONCLUSION: Suprathreshold perimetry using VFE is not suitable as a rapid screening tool for mass screening of glaucoma. VFE cannot be used as a substitute for HVFA in clinic because of its inability to detect early or moderate glaucoma.
format Online
Article
Text
id pubmed-7926121
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-79261212021-03-05 Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population Ichhpujani, Parul Thakur, Sahil Sahi, Roopjit K Kumar, Suresh Indian J Ophthalmol Original Article PURPOSE: The aim of this study was to determine the correlation between the perimetric outcomes using a free application program of the iPad, 'Visual Fields Easy' (VFE), and Humphrey Visual Field Analyzer (HVFA), in normal as well as eyes with glaucomatous damage of varying severity. METHODS: In this prospective, cross-sectional, observational pilot investigation, visual field testing was carried out in 210 eyes of 210 patients (60 Normal, 150 Glaucoma), using suprathreshold VFE application (Version 8) on the iPad and Standard White-on-White using HVFA. Severity of glaucoma was categorized using Hodapp-Anderson-Parrish criteria for visual field defects. The results of the VFE program were compared to the 24-2 SITA FAST HVFA. RESULTS: Data of 210 patients, 100 (47.6%) females, and 110 (52.4%) males, age ranging from 42 to 78 years, Mean 56.64 ± 10.67 years, was analyzed. The Spearman correlation coefficient showed a significant inverse relationship between missed points on the VFE app with MD (S = –0.783) and a parabolic relationship with PSD (S = 0.646) values obtained with the HVFA. As regards missed points, for mild glaucoma, missed points were 37.5, sensitivity was 77.8% and specificity was 52.6%; for moderate glaucoma, missed points were 33.5, sensitivity was 90% and specificity was 48% while for severe glaucoma, missed points were 23, sensitivity was 97% and specificity was 70%. AROC for eyes with mild glaucoma versus normal was 0.419 (95% CI: 0.343-0.495), moderate glaucoma versus normal was 0.705 (95% CI: 0.630-0.780) and severe glaucoma versus normal was 0.857 (95% CI: 0.806-0.908). CONCLUSION: Suprathreshold perimetry using VFE is not suitable as a rapid screening tool for mass screening of glaucoma. VFE cannot be used as a substitute for HVFA in clinic because of its inability to detect early or moderate glaucoma. Wolters Kluwer - Medknow 2021-01 2020-12-15 /pmc/articles/PMC7926121/ /pubmed/33323582 http://dx.doi.org/10.4103/ijo.IJO_1847_19 Text en Copyright: © 2020 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Ichhpujani, Parul
Thakur, Sahil
Sahi, Roopjit K
Kumar, Suresh
Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population
title Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population
title_full Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population
title_fullStr Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population
title_full_unstemmed Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population
title_short Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population
title_sort validating tablet perimetry against standard humphrey visual field analyzer for glaucoma screening in indian population
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7926121/
https://www.ncbi.nlm.nih.gov/pubmed/33323582
http://dx.doi.org/10.4103/ijo.IJO_1847_19
work_keys_str_mv AT ichhpujaniparul validatingtabletperimetryagainststandardhumphreyvisualfieldanalyzerforglaucomascreeninginindianpopulation
AT thakursahil validatingtabletperimetryagainststandardhumphreyvisualfieldanalyzerforglaucomascreeninginindianpopulation
AT sahiroopjitk validatingtabletperimetryagainststandardhumphreyvisualfieldanalyzerforglaucomascreeninginindianpopulation
AT kumarsuresh validatingtabletperimetryagainststandardhumphreyvisualfieldanalyzerforglaucomascreeninginindianpopulation