Cargando…

Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)

BACKGROUND: Digital tomosynthesis (DTS) might be a low-dose/low-cost alternative to computed tomography (CT). PURPOSE: To investigate DTS relative to CT for surveillance of incidental, solid pulmonary nodules. MATERIAL AND METHODS: Recruited from a population study, 106 participants with indetermina...

Descripción completa

Detalles Bibliográficos
Autores principales: Meltzer, Carin, Fagman, Erika, Vikgren, Jenny, Molnar, David, Borna, Eivind, Beni, Maral Mirzai, Brandberg, John, Bergman, Bengt, Båth, Magnus, Johnsson, Åse A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7930602/
https://www.ncbi.nlm.nih.gov/pubmed/32438877
http://dx.doi.org/10.1177/0284185120923106
_version_ 1783660129398292480
author Meltzer, Carin
Fagman, Erika
Vikgren, Jenny
Molnar, David
Borna, Eivind
Beni, Maral Mirzai
Brandberg, John
Bergman, Bengt
Båth, Magnus
Johnsson, Åse A
author_facet Meltzer, Carin
Fagman, Erika
Vikgren, Jenny
Molnar, David
Borna, Eivind
Beni, Maral Mirzai
Brandberg, John
Bergman, Bengt
Båth, Magnus
Johnsson, Åse A
author_sort Meltzer, Carin
collection PubMed
description BACKGROUND: Digital tomosynthesis (DTS) might be a low-dose/low-cost alternative to computed tomography (CT). PURPOSE: To investigate DTS relative to CT for surveillance of incidental, solid pulmonary nodules. MATERIAL AND METHODS: Recruited from a population study, 106 participants with indeterminate solid pulmonary nodules on CT underwent surveillance with concurrently performed CT and DTS. Nodule size on DTS was assessed by manual diameter measurements and semi-automatic nodule segmentations were independently performed on CT. Measurement agreement was analyzed according to Bland–Altman with 95% limits of agreement (LoA). Detection of nodule volume change > 25% by DTS in comparison to CT was evaluated with receiver operating characteristics (ROC). RESULTS: A total of 81 nodules (76%) were assessed as measurable on DTS by two independent observers. Inter- and intra-observer LoA regarding change in average diameter were ± 2 mm. Calculation of relative volume change on DTS resulted in wide inter- and intra-observer LoA in the order of ± 100% and ± 50%. Comparing relative volume change between DTS and CT resulted in LoA of –58% to 67%. The area under the ROC curve regarding the ability of DTS to detect volumetric changes > 25% on CT was 0.58 (95% confidence interval [CI] = 0.40–0.76) and 0.50 (95% CI = 0.35–0.66) for the two observers. CONCLUSION: The results of the present study show that measurement variability limits the agreement between DTS and CT regarding nodule size change for small solid nodules.
format Online
Article
Text
id pubmed-7930602
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-79306022021-03-18 Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS) Meltzer, Carin Fagman, Erika Vikgren, Jenny Molnar, David Borna, Eivind Beni, Maral Mirzai Brandberg, John Bergman, Bengt Båth, Magnus Johnsson, Åse A Acta Radiol Chest Imaging BACKGROUND: Digital tomosynthesis (DTS) might be a low-dose/low-cost alternative to computed tomography (CT). PURPOSE: To investigate DTS relative to CT for surveillance of incidental, solid pulmonary nodules. MATERIAL AND METHODS: Recruited from a population study, 106 participants with indeterminate solid pulmonary nodules on CT underwent surveillance with concurrently performed CT and DTS. Nodule size on DTS was assessed by manual diameter measurements and semi-automatic nodule segmentations were independently performed on CT. Measurement agreement was analyzed according to Bland–Altman with 95% limits of agreement (LoA). Detection of nodule volume change > 25% by DTS in comparison to CT was evaluated with receiver operating characteristics (ROC). RESULTS: A total of 81 nodules (76%) were assessed as measurable on DTS by two independent observers. Inter- and intra-observer LoA regarding change in average diameter were ± 2 mm. Calculation of relative volume change on DTS resulted in wide inter- and intra-observer LoA in the order of ± 100% and ± 50%. Comparing relative volume change between DTS and CT resulted in LoA of –58% to 67%. The area under the ROC curve regarding the ability of DTS to detect volumetric changes > 25% on CT was 0.58 (95% confidence interval [CI] = 0.40–0.76) and 0.50 (95% CI = 0.35–0.66) for the two observers. CONCLUSION: The results of the present study show that measurement variability limits the agreement between DTS and CT regarding nodule size change for small solid nodules. SAGE Publications 2020-05-21 2021-03 /pmc/articles/PMC7930602/ /pubmed/32438877 http://dx.doi.org/10.1177/0284185120923106 Text en © The Foundation Acta Radiologica 2020 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Chest Imaging
Meltzer, Carin
Fagman, Erika
Vikgren, Jenny
Molnar, David
Borna, Eivind
Beni, Maral Mirzai
Brandberg, John
Bergman, Bengt
Båth, Magnus
Johnsson, Åse A
Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)
title Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)
title_full Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)
title_fullStr Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)
title_full_unstemmed Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)
title_short Surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot Swedish CArdioPulmonary bioImage Study (SCAPIS)
title_sort surveillance of small, solid pulmonary nodules at digital chest tomosynthesis: data from a cohort of the pilot swedish cardiopulmonary bioimage study (scapis)
topic Chest Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7930602/
https://www.ncbi.nlm.nih.gov/pubmed/32438877
http://dx.doi.org/10.1177/0284185120923106
work_keys_str_mv AT meltzercarin surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT fagmanerika surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT vikgrenjenny surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT molnardavid surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT bornaeivind surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT benimaralmirzai surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT brandbergjohn surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT bergmanbengt surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT bathmagnus surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis
AT johnssonasea surveillanceofsmallsolidpulmonarynodulesatdigitalchesttomosynthesisdatafromacohortofthepilotswedishcardiopulmonarybioimagestudyscapis