Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis
Heparin-free hemodialysis is often warranted in postoperative states, bleeding diathesis, and critically ill patients. Conventionally, this is achieved through normal saline flushes or regional citrate anticoagulation. An 87-year-old white man with end-stage renal disease and atrial fibrillation, wh...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7930779/ https://www.ncbi.nlm.nih.gov/pubmed/33718796 http://dx.doi.org/10.1016/j.mayocpiqo.2020.08.003 |
_version_ | 1783660155548729344 |
---|---|
author | Locke, Adam Bushey, Margaret A. LaCroix, Cynthia Deardoff, Patience Onuigbo, Macaulay Amechi Chukwukadibia |
author_facet | Locke, Adam Bushey, Margaret A. LaCroix, Cynthia Deardoff, Patience Onuigbo, Macaulay Amechi Chukwukadibia |
author_sort | Locke, Adam |
collection | PubMed |
description | Heparin-free hemodialysis is often warranted in postoperative states, bleeding diathesis, and critically ill patients. Conventionally, this is achieved through normal saline flushes or regional citrate anticoagulation. An 87-year-old white man with end-stage renal disease and atrial fibrillation, who was taking warfarin and using maintenance home hemodialysis (HHD) with an NxStage machine, underwent laparoscopic appendicectomy. The procedure was complicated by intra-abdominal abscess, sepsis, and tamponade from a bloody pericardial effusion. He needed emergent therapeutic pericardiocentesis. Warfarin was promptly discontinued. He was discharged home with heparin-free HHD. Prior heparin anticoagulation for HHD was an initial bolus of 4000 units of heparin. He continued to clot his extracorporeal system with resultant very high venous pressures and compromised HHD. Heparin anticoagulation was still contraindicated. Flushes with 250-500 mL normal saline, delivered in aliquots every 15-30 minutes, failed to prevent the frequent clotting. The first author, our HD Senior Technician, had astutely observed that the horizontally placed hemodialysis filter exhibited early “clot” formation at the 12-o’clock position, despite the saline flushes. Through trial and error, he discovered that rotating the horizontally placed hemodialysis filter along its long axis, 60 degrees clockwise for 15 minutes, return to the neutral position for 15 minutes, rotating the filter another 60 degrees counterclockwise for 15 minutes, with this repeated cycle of rotations “did the trick.” It promptly and consistently resolved the clotting problem. The lines stopped clotting, and he has not needed saline flushes for smooth heparin-free HHD for more than 7 months. To our knowledge, this is the first such report. Further study is justified. We have hypothesized a mechanism and have named this the “Locke-Onuigbo Maneuver.” |
format | Online Article Text |
id | pubmed-7930779 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-79307792021-03-12 Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis Locke, Adam Bushey, Margaret A. LaCroix, Cynthia Deardoff, Patience Onuigbo, Macaulay Amechi Chukwukadibia Mayo Clin Proc Innov Qual Outcomes Case Report Heparin-free hemodialysis is often warranted in postoperative states, bleeding diathesis, and critically ill patients. Conventionally, this is achieved through normal saline flushes or regional citrate anticoagulation. An 87-year-old white man with end-stage renal disease and atrial fibrillation, who was taking warfarin and using maintenance home hemodialysis (HHD) with an NxStage machine, underwent laparoscopic appendicectomy. The procedure was complicated by intra-abdominal abscess, sepsis, and tamponade from a bloody pericardial effusion. He needed emergent therapeutic pericardiocentesis. Warfarin was promptly discontinued. He was discharged home with heparin-free HHD. Prior heparin anticoagulation for HHD was an initial bolus of 4000 units of heparin. He continued to clot his extracorporeal system with resultant very high venous pressures and compromised HHD. Heparin anticoagulation was still contraindicated. Flushes with 250-500 mL normal saline, delivered in aliquots every 15-30 minutes, failed to prevent the frequent clotting. The first author, our HD Senior Technician, had astutely observed that the horizontally placed hemodialysis filter exhibited early “clot” formation at the 12-o’clock position, despite the saline flushes. Through trial and error, he discovered that rotating the horizontally placed hemodialysis filter along its long axis, 60 degrees clockwise for 15 minutes, return to the neutral position for 15 minutes, rotating the filter another 60 degrees counterclockwise for 15 minutes, with this repeated cycle of rotations “did the trick.” It promptly and consistently resolved the clotting problem. The lines stopped clotting, and he has not needed saline flushes for smooth heparin-free HHD for more than 7 months. To our knowledge, this is the first such report. Further study is justified. We have hypothesized a mechanism and have named this the “Locke-Onuigbo Maneuver.” Elsevier 2020-11-06 /pmc/articles/PMC7930779/ /pubmed/33718796 http://dx.doi.org/10.1016/j.mayocpiqo.2020.08.003 Text en © 2020 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Locke, Adam Bushey, Margaret A. LaCroix, Cynthia Deardoff, Patience Onuigbo, Macaulay Amechi Chukwukadibia Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis |
title | Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis |
title_full | Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis |
title_fullStr | Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis |
title_full_unstemmed | Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis |
title_short | Timed Controlled Repeated Rotation of the CAR-170-C NXSTAGE Chronic Cartridge Hemodialysis Filter: A Novel Approach to Enabling Heparin-Free Frequent Daily Home Hemodialysis |
title_sort | timed controlled repeated rotation of the car-170-c nxstage chronic cartridge hemodialysis filter: a novel approach to enabling heparin-free frequent daily home hemodialysis |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7930779/ https://www.ncbi.nlm.nih.gov/pubmed/33718796 http://dx.doi.org/10.1016/j.mayocpiqo.2020.08.003 |
work_keys_str_mv | AT lockeadam timedcontrolledrepeatedrotationofthecar170cnxstagechroniccartridgehemodialysisfilteranovelapproachtoenablingheparinfreefrequentdailyhomehemodialysis AT busheymargareta timedcontrolledrepeatedrotationofthecar170cnxstagechroniccartridgehemodialysisfilteranovelapproachtoenablingheparinfreefrequentdailyhomehemodialysis AT lacroixcynthia timedcontrolledrepeatedrotationofthecar170cnxstagechroniccartridgehemodialysisfilteranovelapproachtoenablingheparinfreefrequentdailyhomehemodialysis AT deardoffpatience timedcontrolledrepeatedrotationofthecar170cnxstagechroniccartridgehemodialysisfilteranovelapproachtoenablingheparinfreefrequentdailyhomehemodialysis AT onuigbomacaulayamechichukwukadibia timedcontrolledrepeatedrotationofthecar170cnxstagechroniccartridgehemodialysisfilteranovelapproachtoenablingheparinfreefrequentdailyhomehemodialysis |