Cargando…

The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients

The study was undertaken to evaluate the performance of Unyvero Hospitalized Pneumonia (HPN) panel application, a multiplex PCR-based method for the detection of bacterial pathogens from lower respiratory tract (LRT) samples, obtained from COVID-19 patients with suspected secondary hospital-acquired...

Descripción completa

Detalles Bibliográficos
Autores principales: Tellapragada, Chaitanya, Giske, Christian G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7930892/
https://www.ncbi.nlm.nih.gov/pubmed/33661410
http://dx.doi.org/10.1007/s10096-021-04194-6
_version_ 1783660176813850624
author Tellapragada, Chaitanya
Giske, Christian G.
author_facet Tellapragada, Chaitanya
Giske, Christian G.
author_sort Tellapragada, Chaitanya
collection PubMed
description The study was undertaken to evaluate the performance of Unyvero Hospitalized Pneumonia (HPN) panel application, a multiplex PCR-based method for the detection of bacterial pathogens from lower respiratory tract (LRT) samples, obtained from COVID-19 patients with suspected secondary hospital-acquired pneumonia. Residual LRT samples obtained from critically ill COVID-19 patients with predetermined microbiological culture results were tested using the Unyvero HPN Application. Performance evaluation of the HPN Application was carried out using the standard-of-care (SoC) microbiological culture findings as the reference method. Eighty-three LRT samples were used in the evaluation. The HPN Application had a full concordance with SoC findings in 59/83 (71%) samples. The new method detected additional bacterial species in 21 (25%) and failed at detecting a bacterial species present in lower respiratory culture in 3 (3.6%) samples. Overall the sensitivity, specificity, positive, and negative predictive values of the HPN Application were 95.1% (95%CI 96.5–98.3%), 98.3% (95% CI 97.5–98.9%), 71.6% (95% CI 61.0–80.3%), and 99.8% (95% CI 99.3–99.9%), respectively. In conclusion, the HPN Application demonstrated higher diagnostic yield in comparison with the culture and generated results within 5 h. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-021-04194-6.
format Online
Article
Text
id pubmed-7930892
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-79308922021-03-04 The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients Tellapragada, Chaitanya Giske, Christian G. Eur J Clin Microbiol Infect Dis Original Article The study was undertaken to evaluate the performance of Unyvero Hospitalized Pneumonia (HPN) panel application, a multiplex PCR-based method for the detection of bacterial pathogens from lower respiratory tract (LRT) samples, obtained from COVID-19 patients with suspected secondary hospital-acquired pneumonia. Residual LRT samples obtained from critically ill COVID-19 patients with predetermined microbiological culture results were tested using the Unyvero HPN Application. Performance evaluation of the HPN Application was carried out using the standard-of-care (SoC) microbiological culture findings as the reference method. Eighty-three LRT samples were used in the evaluation. The HPN Application had a full concordance with SoC findings in 59/83 (71%) samples. The new method detected additional bacterial species in 21 (25%) and failed at detecting a bacterial species present in lower respiratory culture in 3 (3.6%) samples. Overall the sensitivity, specificity, positive, and negative predictive values of the HPN Application were 95.1% (95%CI 96.5–98.3%), 98.3% (95% CI 97.5–98.9%), 71.6% (95% CI 61.0–80.3%), and 99.8% (95% CI 99.3–99.9%), respectively. In conclusion, the HPN Application demonstrated higher diagnostic yield in comparison with the culture and generated results within 5 h. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-021-04194-6. Springer Berlin Heidelberg 2021-03-04 2021 /pmc/articles/PMC7930892/ /pubmed/33661410 http://dx.doi.org/10.1007/s10096-021-04194-6 Text en © The Author(s) 2021, corrected publication 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Tellapragada, Chaitanya
Giske, Christian G.
The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients
title The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients
title_full The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients
title_fullStr The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients
title_full_unstemmed The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients
title_short The Unyvero Hospital-Acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in COVID-19 patients
title_sort unyvero hospital-acquired pneumonia panel for diagnosis of secondary bacterial pneumonia in covid-19 patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7930892/
https://www.ncbi.nlm.nih.gov/pubmed/33661410
http://dx.doi.org/10.1007/s10096-021-04194-6
work_keys_str_mv AT tellapragadachaitanya theunyverohospitalacquiredpneumoniapanelfordiagnosisofsecondarybacterialpneumoniaincovid19patients
AT giskechristiang theunyverohospitalacquiredpneumoniapanelfordiagnosisofsecondarybacterialpneumoniaincovid19patients
AT tellapragadachaitanya unyverohospitalacquiredpneumoniapanelfordiagnosisofsecondarybacterialpneumoniaincovid19patients
AT giskechristiang unyverohospitalacquiredpneumoniapanelfordiagnosisofsecondarybacterialpneumoniaincovid19patients