Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor

Background: Hypertension in patients with atrial fibrillation (AF) is a known independent risk factor for stroke. The Complete blood pressure (BP) monitor (Omron Healthcare, Kyoto, Japan) was developed as the first BP monitor with electrocardiogram (ECG) capability in a single device to simultaneous...

Descripción completa

Detalles Bibliográficos
Autores principales: Senoo, Keitaro, Miki, Tomonori, Okura, Takashi, Shiraishi, Hirokazu, Shirayama, Takeshi, Inoue, Keiji, Sakatani, Tomohiko, Kakita, Ken, Hattori, Tetsuhisa, Nakai, Kentaro, Ikeda, Takanori, Matoba, Satoaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Circulation Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7932817/
https://www.ncbi.nlm.nih.gov/pubmed/33693251
http://dx.doi.org/10.1253/circrep.CR-20-0032
_version_ 1783660493095829504
author Senoo, Keitaro
Miki, Tomonori
Okura, Takashi
Shiraishi, Hirokazu
Shirayama, Takeshi
Inoue, Keiji
Sakatani, Tomohiko
Kakita, Ken
Hattori, Tetsuhisa
Nakai, Kentaro
Ikeda, Takanori
Matoba, Satoaki
author_facet Senoo, Keitaro
Miki, Tomonori
Okura, Takashi
Shiraishi, Hirokazu
Shirayama, Takeshi
Inoue, Keiji
Sakatani, Tomohiko
Kakita, Ken
Hattori, Tetsuhisa
Nakai, Kentaro
Ikeda, Takanori
Matoba, Satoaki
author_sort Senoo, Keitaro
collection PubMed
description Background: Hypertension in patients with atrial fibrillation (AF) is a known independent risk factor for stroke. The Complete blood pressure (BP) monitor (Omron Healthcare, Kyoto, Japan) was developed as the first BP monitor with electrocardiogram (ECG) capability in a single device to simultaneously monitor ECG and BP readings. This study investigated whether the Complete can accurately differentiate sinus rhythm (SR) from AF during BP measurement. Methods and Results: Fifty-six consecutive patients with persistent AF admitted for catheter ablation were enrolled in the study (mean age 65.8 years; 83.9% male). In all patients, 12-lead ECGs and simultaneous Complete recordings were acquired before and after ablation. The Complete interpretations were compared with physician-reviewed ECGs, whereas Complete recordings were reviewed by cardiologists in a blinded manner and compared with ECG interpretations. Sensitivity, specificity, and κ coefficient were also determined. In all, 164 Complete and ECG recordings were simultaneously acquired from the 56 patients. After excluding unclassified recordings, the Complete automated algorithm performed well, with 100% sensitivity, 86% specificity, and a κ coefficient of 0.87 compared with physician-interpreted ECGs. Physician-interpreted Complete recordings performed well, with 99% sensitivity, 85% specificity, and a κ coefficient of 0.85 compared with physician-interpreted ECGs. Conclusions: The Complete, which combines BP and ECG monitoring, can accurately differentiate SR from AF during BP measurement.
format Online
Article
Text
id pubmed-7932817
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Japanese Circulation Society
record_format MEDLINE/PubMed
spelling pubmed-79328172021-03-09 Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor Senoo, Keitaro Miki, Tomonori Okura, Takashi Shiraishi, Hirokazu Shirayama, Takeshi Inoue, Keiji Sakatani, Tomohiko Kakita, Ken Hattori, Tetsuhisa Nakai, Kentaro Ikeda, Takanori Matoba, Satoaki Circ Rep Original article Background: Hypertension in patients with atrial fibrillation (AF) is a known independent risk factor for stroke. The Complete blood pressure (BP) monitor (Omron Healthcare, Kyoto, Japan) was developed as the first BP monitor with electrocardiogram (ECG) capability in a single device to simultaneously monitor ECG and BP readings. This study investigated whether the Complete can accurately differentiate sinus rhythm (SR) from AF during BP measurement. Methods and Results: Fifty-six consecutive patients with persistent AF admitted for catheter ablation were enrolled in the study (mean age 65.8 years; 83.9% male). In all patients, 12-lead ECGs and simultaneous Complete recordings were acquired before and after ablation. The Complete interpretations were compared with physician-reviewed ECGs, whereas Complete recordings were reviewed by cardiologists in a blinded manner and compared with ECG interpretations. Sensitivity, specificity, and κ coefficient were also determined. In all, 164 Complete and ECG recordings were simultaneously acquired from the 56 patients. After excluding unclassified recordings, the Complete automated algorithm performed well, with 100% sensitivity, 86% specificity, and a κ coefficient of 0.87 compared with physician-interpreted ECGs. Physician-interpreted Complete recordings performed well, with 99% sensitivity, 85% specificity, and a κ coefficient of 0.85 compared with physician-interpreted ECGs. Conclusions: The Complete, which combines BP and ECG monitoring, can accurately differentiate SR from AF during BP measurement. The Japanese Circulation Society 2020-05-27 /pmc/articles/PMC7932817/ /pubmed/33693251 http://dx.doi.org/10.1253/circrep.CR-20-0032 Text en Copyright © 2020, THE JAPANESE CIRCULATION SOCIETY This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Original article
Senoo, Keitaro
Miki, Tomonori
Okura, Takashi
Shiraishi, Hirokazu
Shirayama, Takeshi
Inoue, Keiji
Sakatani, Tomohiko
Kakita, Ken
Hattori, Tetsuhisa
Nakai, Kentaro
Ikeda, Takanori
Matoba, Satoaki
Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor
title Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor
title_full Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor
title_fullStr Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor
title_full_unstemmed Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor
title_short Diagnostic Value of Atrial Fibrillation by Built-in Electrocardiogram Technology in a Blood Pressure Monitor
title_sort diagnostic value of atrial fibrillation by built-in electrocardiogram technology in a blood pressure monitor
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7932817/
https://www.ncbi.nlm.nih.gov/pubmed/33693251
http://dx.doi.org/10.1253/circrep.CR-20-0032
work_keys_str_mv AT senookeitaro diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT mikitomonori diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT okuratakashi diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT shiraishihirokazu diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT shirayamatakeshi diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT inouekeiji diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT sakatanitomohiko diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT kakitaken diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT hattoritetsuhisa diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT nakaikentaro diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT ikedatakanori diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor
AT matobasatoaki diagnosticvalueofatrialfibrillationbybuiltinelectrocardiogramtechnologyinabloodpressuremonitor