MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation
Scleral-fixated intraocular lens implantation in an important tool in the armamentarium of an ophthalmologist for managing aphakia. Various techniques have been described in the literature with variable learning curves. Herein, we describe an easy, fast, reproducible technique; the “MYX” technique,...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7933830/ https://www.ncbi.nlm.nih.gov/pubmed/33463604 http://dx.doi.org/10.4103/ijo.IJO_728_20 |
_version_ | 1783660697865945088 |
---|---|
author | Bhatia, Karan Manaktala, Ruchita Sachdev, Mahipal Tank, Nikunj Saha, Indranil Mishra, Deepak |
author_facet | Bhatia, Karan Manaktala, Ruchita Sachdev, Mahipal Tank, Nikunj Saha, Indranil Mishra, Deepak |
author_sort | Bhatia, Karan |
collection | PubMed |
description | Scleral-fixated intraocular lens implantation in an important tool in the armamentarium of an ophthalmologist for managing aphakia. Various techniques have been described in the literature with variable learning curves. Herein, we describe an easy, fast, reproducible technique; the “MYX” technique, which utilizes the advantages of both the Yamane and the X-NIT technique, where the handshaking of the prolene haptic of a 3-piece PMMA IOL into the lumen of a 26-gauge needle is done externally (like in X-NIT technique), and the exteriorized haptic is cauterized to form a flange transconjunctivally, thereby avoiding the scleral pocket tucking (like Yamane technique), to achieve excellent surgical outcomes. |
format | Online Article Text |
id | pubmed-7933830 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-79338302021-03-08 MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation Bhatia, Karan Manaktala, Ruchita Sachdev, Mahipal Tank, Nikunj Saha, Indranil Mishra, Deepak Indian J Ophthalmol Surgical Technique Scleral-fixated intraocular lens implantation in an important tool in the armamentarium of an ophthalmologist for managing aphakia. Various techniques have been described in the literature with variable learning curves. Herein, we describe an easy, fast, reproducible technique; the “MYX” technique, which utilizes the advantages of both the Yamane and the X-NIT technique, where the handshaking of the prolene haptic of a 3-piece PMMA IOL into the lumen of a 26-gauge needle is done externally (like in X-NIT technique), and the exteriorized haptic is cauterized to form a flange transconjunctivally, thereby avoiding the scleral pocket tucking (like Yamane technique), to achieve excellent surgical outcomes. Wolters Kluwer - Medknow 2021-02 2021-01-18 /pmc/articles/PMC7933830/ /pubmed/33463604 http://dx.doi.org/10.4103/ijo.IJO_728_20 Text en Copyright: © 2021 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Surgical Technique Bhatia, Karan Manaktala, Ruchita Sachdev, Mahipal Tank, Nikunj Saha, Indranil Mishra, Deepak MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation |
title | MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation |
title_full | MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation |
title_fullStr | MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation |
title_full_unstemmed | MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation |
title_short | MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation |
title_sort | myx technique: a modified adaptation of yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7933830/ https://www.ncbi.nlm.nih.gov/pubmed/33463604 http://dx.doi.org/10.4103/ijo.IJO_728_20 |
work_keys_str_mv | AT bhatiakaran myxtechniqueamodifiedadaptationofyamaneandextraocularneedleguidedhapticinsertiontechniquesforscleralfixatedintraocularlensimplantation AT manaktalaruchita myxtechniqueamodifiedadaptationofyamaneandextraocularneedleguidedhapticinsertiontechniquesforscleralfixatedintraocularlensimplantation AT sachdevmahipal myxtechniqueamodifiedadaptationofyamaneandextraocularneedleguidedhapticinsertiontechniquesforscleralfixatedintraocularlensimplantation AT tanknikunj myxtechniqueamodifiedadaptationofyamaneandextraocularneedleguidedhapticinsertiontechniquesforscleralfixatedintraocularlensimplantation AT sahaindranil myxtechniqueamodifiedadaptationofyamaneandextraocularneedleguidedhapticinsertiontechniquesforscleralfixatedintraocularlensimplantation AT mishradeepak myxtechniqueamodifiedadaptationofyamaneandextraocularneedleguidedhapticinsertiontechniquesforscleralfixatedintraocularlensimplantation |