Cargando…
Virus containment box for retinopathy of prematurity screening and laser
PURPOSE: Health care workers are susceptible to contracting infection with COVID-19 by aerosol transmission. This is a risk while examining and/or treating an un-sedated neonate in retinopathy of prematurity (ROP) screening and treatment. But screening for neonates for ROP and treating with laser, w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7933880/ https://www.ncbi.nlm.nih.gov/pubmed/33402657 http://dx.doi.org/10.4103/ijo.IJO_2304_20 |
_version_ | 1783660709693882368 |
---|---|
author | Nayak, Sameera Reddy, Y P Behera, Shashwat Adish, T S Satyanarayana, D |
author_facet | Nayak, Sameera Reddy, Y P Behera, Shashwat Adish, T S Satyanarayana, D |
author_sort | Nayak, Sameera |
collection | PubMed |
description | PURPOSE: Health care workers are susceptible to contracting infection with COVID-19 by aerosol transmission. This is a risk while examining and/or treating an un-sedated neonate in retinopathy of prematurity (ROP) screening and treatment. But screening for neonates for ROP and treating with laser, when required, should not be delayed to avoid the blindness. We describe a cost-effective method of containing aerosols generated during such a procedure in an un-sedated baby. METHODS: An acrylic transparent containment box was prepared to accommodate an average-sized infant. The box had four walls and a roof. The floor was open to place the container box over the baby. The walls have two types of openings, large ones to allow passage of hands to examine the baby, small ones to enable passage of oxygen tubing when required. A simulation was created to examine the impact of aerosol spray on examining healthcare personnel. RESULTS: The cost of the acrylic box was negligible. It could be assembled locally with available acrylic sheets and craftsmen. It was not difficult to examine the baby inside the box, and the simulation demonstrated that it protected the health personnel from the aerosol contamination. CONCLUSION: The described method is likely to increase healthcare personnel's confidence not to delay or deny ROP screening and laser treatment and save the babies from blindness. |
format | Online Article Text |
id | pubmed-7933880 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-79338802021-03-08 Virus containment box for retinopathy of prematurity screening and laser Nayak, Sameera Reddy, Y P Behera, Shashwat Adish, T S Satyanarayana, D Indian J Ophthalmol Expedited Publication, Innovations in Ophthalmology PURPOSE: Health care workers are susceptible to contracting infection with COVID-19 by aerosol transmission. This is a risk while examining and/or treating an un-sedated neonate in retinopathy of prematurity (ROP) screening and treatment. But screening for neonates for ROP and treating with laser, when required, should not be delayed to avoid the blindness. We describe a cost-effective method of containing aerosols generated during such a procedure in an un-sedated baby. METHODS: An acrylic transparent containment box was prepared to accommodate an average-sized infant. The box had four walls and a roof. The floor was open to place the container box over the baby. The walls have two types of openings, large ones to allow passage of hands to examine the baby, small ones to enable passage of oxygen tubing when required. A simulation was created to examine the impact of aerosol spray on examining healthcare personnel. RESULTS: The cost of the acrylic box was negligible. It could be assembled locally with available acrylic sheets and craftsmen. It was not difficult to examine the baby inside the box, and the simulation demonstrated that it protected the health personnel from the aerosol contamination. CONCLUSION: The described method is likely to increase healthcare personnel's confidence not to delay or deny ROP screening and laser treatment and save the babies from blindness. Wolters Kluwer - Medknow 2021-02 2020-12-31 /pmc/articles/PMC7933880/ /pubmed/33402657 http://dx.doi.org/10.4103/ijo.IJO_2304_20 Text en Copyright: © 2020 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Expedited Publication, Innovations in Ophthalmology Nayak, Sameera Reddy, Y P Behera, Shashwat Adish, T S Satyanarayana, D Virus containment box for retinopathy of prematurity screening and laser |
title | Virus containment box for retinopathy of prematurity screening and laser |
title_full | Virus containment box for retinopathy of prematurity screening and laser |
title_fullStr | Virus containment box for retinopathy of prematurity screening and laser |
title_full_unstemmed | Virus containment box for retinopathy of prematurity screening and laser |
title_short | Virus containment box for retinopathy of prematurity screening and laser |
title_sort | virus containment box for retinopathy of prematurity screening and laser |
topic | Expedited Publication, Innovations in Ophthalmology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7933880/ https://www.ncbi.nlm.nih.gov/pubmed/33402657 http://dx.doi.org/10.4103/ijo.IJO_2304_20 |
work_keys_str_mv | AT nayaksameera viruscontainmentboxforretinopathyofprematurityscreeningandlaser AT reddyyp viruscontainmentboxforretinopathyofprematurityscreeningandlaser AT beherashashwat viruscontainmentboxforretinopathyofprematurityscreeningandlaser AT adishts viruscontainmentboxforretinopathyofprematurityscreeningandlaser AT satyanarayanad viruscontainmentboxforretinopathyofprematurityscreeningandlaser |