Cargando…
Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies
BACKGROUND: Serological test is an essential surveillance tool to track down the extensiveness of SARS-CoV-2 transmission and subsequently to move out from the enforced lockdown stage. OBJECTIVE: The study measures the diagnostic accuracy of three popular chemiluminescent immunoassay (CLIA) based au...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7934617/ https://www.ncbi.nlm.nih.gov/pubmed/33684402 http://dx.doi.org/10.1016/j.jviromet.2021.114121 |
_version_ | 1783660851372228608 |
---|---|
author | Parai, Debaprasad Dash, Girish Chandra Choudhary, Hari Ram Peter, Annalisha Rout, Usha Kiran Nanda, Rashmi Ranjan Kshatri, Jaya Singh Kanungo, Srikanta Pati, Sanghamitra Bhattacharya, Debdutta |
author_facet | Parai, Debaprasad Dash, Girish Chandra Choudhary, Hari Ram Peter, Annalisha Rout, Usha Kiran Nanda, Rashmi Ranjan Kshatri, Jaya Singh Kanungo, Srikanta Pati, Sanghamitra Bhattacharya, Debdutta |
author_sort | Parai, Debaprasad |
collection | PubMed |
description | BACKGROUND: Serological test is an essential surveillance tool to track down the extensiveness of SARS-CoV-2 transmission and subsequently to move out from the enforced lockdown stage. OBJECTIVE: The study measures the diagnostic accuracy of three popular chemiluminescent immunoassay (CLIA) based automated platforms for the detection of anti-SARS-CoV-2 antibodies and compares their agreements. STUDY DESIGN: Serum samples of 594 COVID-19 positive patients and 100 samples from pre-COVID cases were tested by three CLIA based automated platforms: Abbott architect i2000SR, Roche cobas e411 and Yhlo iFlash 1800 and their diagnostic accuracy were compared by the area under the curves (AUC) value obtained from receiver operator characteristic (ROC) curves. Cohen’s kappa statistic and McNemar’s test were used to interpret the agreement between the platforms. RESULTS: All three platforms showed high specificity as claimed by the manufacturer. Sensitivity was calculated as 64.48 % (58.67–70.3) for Abbott, 80.48 % (76.62–84.34) for Roche and 76.94 % (72.65–81.23) for Yhlo. AUC was maximum for Roche (0.929). The Cohen’s kappa value was determined in between 0.69−0.89 as the inter-rater agreements. CONCLUSION: The overall statistical analysis demonstrated cobas e411 as the diagnostically most accurate platform among the three. |
format | Online Article Text |
id | pubmed-7934617 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-79346172021-03-05 Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies Parai, Debaprasad Dash, Girish Chandra Choudhary, Hari Ram Peter, Annalisha Rout, Usha Kiran Nanda, Rashmi Ranjan Kshatri, Jaya Singh Kanungo, Srikanta Pati, Sanghamitra Bhattacharya, Debdutta J Virol Methods Short Communication BACKGROUND: Serological test is an essential surveillance tool to track down the extensiveness of SARS-CoV-2 transmission and subsequently to move out from the enforced lockdown stage. OBJECTIVE: The study measures the diagnostic accuracy of three popular chemiluminescent immunoassay (CLIA) based automated platforms for the detection of anti-SARS-CoV-2 antibodies and compares their agreements. STUDY DESIGN: Serum samples of 594 COVID-19 positive patients and 100 samples from pre-COVID cases were tested by three CLIA based automated platforms: Abbott architect i2000SR, Roche cobas e411 and Yhlo iFlash 1800 and their diagnostic accuracy were compared by the area under the curves (AUC) value obtained from receiver operator characteristic (ROC) curves. Cohen’s kappa statistic and McNemar’s test were used to interpret the agreement between the platforms. RESULTS: All three platforms showed high specificity as claimed by the manufacturer. Sensitivity was calculated as 64.48 % (58.67–70.3) for Abbott, 80.48 % (76.62–84.34) for Roche and 76.94 % (72.65–81.23) for Yhlo. AUC was maximum for Roche (0.929). The Cohen’s kappa value was determined in between 0.69−0.89 as the inter-rater agreements. CONCLUSION: The overall statistical analysis demonstrated cobas e411 as the diagnostically most accurate platform among the three. Elsevier B.V. 2021-06 2021-03-05 /pmc/articles/PMC7934617/ /pubmed/33684402 http://dx.doi.org/10.1016/j.jviromet.2021.114121 Text en © 2021 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Short Communication Parai, Debaprasad Dash, Girish Chandra Choudhary, Hari Ram Peter, Annalisha Rout, Usha Kiran Nanda, Rashmi Ranjan Kshatri, Jaya Singh Kanungo, Srikanta Pati, Sanghamitra Bhattacharya, Debdutta Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies |
title | Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies |
title_full | Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies |
title_fullStr | Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies |
title_full_unstemmed | Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies |
title_short | Diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies |
title_sort | diagnostic accuracy comparison of three fully automated chemiluminescent immunoassay platforms for the detection of sars-cov-2 antibodies |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7934617/ https://www.ncbi.nlm.nih.gov/pubmed/33684402 http://dx.doi.org/10.1016/j.jviromet.2021.114121 |
work_keys_str_mv | AT paraidebaprasad diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT dashgirishchandra diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT choudharyhariram diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT peterannalisha diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT routushakiran diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT nandarashmiranjan diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT kshatrijayasingh diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT kanungosrikanta diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT patisanghamitra diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies AT bhattacharyadebdutta diagnosticaccuracycomparisonofthreefullyautomatedchemiluminescentimmunoassayplatformsforthedetectionofsarscov2antibodies |