Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ―

Background: We hypothesized that the intracoronary-electrocardiogram (IC-ECG)-based pressure index would be more stable and precise than the instantaneous flow reserve (iFR). We investigated the usefulness of the IC-ECG-based pressure index for diagnosing myocardial ischemia. Methods and Results: Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakayama, Masafumi, Uchiyama, Takashi, Tanaka, Nobuhiro, Ohkawauchi, Takaaki, Miwa, Shunsuke, Hijikata, Nobuhiro, Kobori, Yuichi, Matsuo, Hitoshi, Iwasaki, Kiyotaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Circulation Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7937502/
https://www.ncbi.nlm.nih.gov/pubmed/33693193
http://dx.doi.org/10.1253/circrep.CR-20-0099
_version_ 1783661404540108800
author Nakayama, Masafumi
Uchiyama, Takashi
Tanaka, Nobuhiro
Ohkawauchi, Takaaki
Miwa, Shunsuke
Hijikata, Nobuhiro
Kobori, Yuichi
Matsuo, Hitoshi
Iwasaki, Kiyotaka
author_facet Nakayama, Masafumi
Uchiyama, Takashi
Tanaka, Nobuhiro
Ohkawauchi, Takaaki
Miwa, Shunsuke
Hijikata, Nobuhiro
Kobori, Yuichi
Matsuo, Hitoshi
Iwasaki, Kiyotaka
author_sort Nakayama, Masafumi
collection PubMed
description Background: We hypothesized that the intracoronary-electrocardiogram (IC-ECG)-based pressure index would be more stable and precise than the instantaneous flow reserve (iFR). We investigated the usefulness of the IC-ECG-based pressure index for diagnosing myocardial ischemia. Methods and Results: Thirty-seven consecutive patients with coronary stenosis requiring physiological assessment were enrolled in the study. iFR was measured at rest and under hyperemia in 51 and 40 lesions, respectively. The IC-ECG-triggered distal pressure (Pd)/aortic pressure (Pa) ratio (ICE-T) was defined as the mean Pd/Pa ratio in the period corresponding to the isoelectric line. The ICE-T was significantly lower than the iFR both at rest and during hyperemia (P<0.00001 for both). Fluctuations in the ICE-T pressure parameters (Pd/Pa, Pa, and Pd) were significantly smaller than those of iFR both at rest and during hyperemia. The diagnostic accuracy of predicting a fractional flow reserve (FFR) ≤0.80 of the ICE-T at rest was significantly higher than that of iFR (P=0.008). Receiver operating characteristic curve analyses showed that the ICE-T predicts FFR ≤0.80 more accurately than the iFR (area under curve 0.897 vs. 0.810 for ICE-T and iFR, respectively). Conclusions: We identified the period in the IC-ECG in which resting Pd/Pa was low and constant. The IC-ECG-based algorithm may improve the accuracy of diagnosing myocardial ischemia, without increasing invasiveness, compared with pressure-dependent indices.
format Online
Article
Text
id pubmed-7937502
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Japanese Circulation Society
record_format MEDLINE/PubMed
spelling pubmed-79375022021-03-09 Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ― Nakayama, Masafumi Uchiyama, Takashi Tanaka, Nobuhiro Ohkawauchi, Takaaki Miwa, Shunsuke Hijikata, Nobuhiro Kobori, Yuichi Matsuo, Hitoshi Iwasaki, Kiyotaka Circ Rep Original article Background: We hypothesized that the intracoronary-electrocardiogram (IC-ECG)-based pressure index would be more stable and precise than the instantaneous flow reserve (iFR). We investigated the usefulness of the IC-ECG-based pressure index for diagnosing myocardial ischemia. Methods and Results: Thirty-seven consecutive patients with coronary stenosis requiring physiological assessment were enrolled in the study. iFR was measured at rest and under hyperemia in 51 and 40 lesions, respectively. The IC-ECG-triggered distal pressure (Pd)/aortic pressure (Pa) ratio (ICE-T) was defined as the mean Pd/Pa ratio in the period corresponding to the isoelectric line. The ICE-T was significantly lower than the iFR both at rest and during hyperemia (P<0.00001 for both). Fluctuations in the ICE-T pressure parameters (Pd/Pa, Pa, and Pd) were significantly smaller than those of iFR both at rest and during hyperemia. The diagnostic accuracy of predicting a fractional flow reserve (FFR) ≤0.80 of the ICE-T at rest was significantly higher than that of iFR (P=0.008). Receiver operating characteristic curve analyses showed that the ICE-T predicts FFR ≤0.80 more accurately than the iFR (area under curve 0.897 vs. 0.810 for ICE-T and iFR, respectively). Conclusions: We identified the period in the IC-ECG in which resting Pd/Pa was low and constant. The IC-ECG-based algorithm may improve the accuracy of diagnosing myocardial ischemia, without increasing invasiveness, compared with pressure-dependent indices. The Japanese Circulation Society 2020-10-23 /pmc/articles/PMC7937502/ /pubmed/33693193 http://dx.doi.org/10.1253/circrep.CR-20-0099 Text en Copyright © 2020, THE JAPANESE CIRCULATION SOCIETY This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Original article
Nakayama, Masafumi
Uchiyama, Takashi
Tanaka, Nobuhiro
Ohkawauchi, Takaaki
Miwa, Shunsuke
Hijikata, Nobuhiro
Kobori, Yuichi
Matsuo, Hitoshi
Iwasaki, Kiyotaka
Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ―
title Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ―
title_full Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ―
title_fullStr Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ―
title_full_unstemmed Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ―
title_short Diagnostic Performance and Pressure Stability of a Novel Myocardial Ischemic Diagnostic Index ― The Intracoronary-Electrocardiogram-Triggered Distal Pressure/Aortic Pressure Ratio ―
title_sort diagnostic performance and pressure stability of a novel myocardial ischemic diagnostic index ― the intracoronary-electrocardiogram-triggered distal pressure/aortic pressure ratio ―
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7937502/
https://www.ncbi.nlm.nih.gov/pubmed/33693193
http://dx.doi.org/10.1253/circrep.CR-20-0099
work_keys_str_mv AT nakayamamasafumi diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT uchiyamatakashi diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT tanakanobuhiro diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT ohkawauchitakaaki diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT miwashunsuke diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT hijikatanobuhiro diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT koboriyuichi diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT matsuohitoshi diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio
AT iwasakikiyotaka diagnosticperformanceandpressurestabilityofanovelmyocardialischemicdiagnosticindextheintracoronaryelectrocardiogramtriggereddistalpressureaorticpressureratio