Cargando…

Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report

INTRODUCTION AND IMPORTANCE: As the population grows older, femoral neck fracture is becoming one of the prevalent cases in orthopedics, although this fracture can also happen in younger individuals following high energy traumas. Fixation with cancellous lag screws is one treatment option for femora...

Descripción completa

Detalles Bibliográficos
Autores principales: Najjari, Khosrow, Gouravani, Mahdi, Hajebi, Reza, Zabihi Mahmoudabadi, Hossein, Rahimpour, Ehsan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7937741/
https://www.ncbi.nlm.nih.gov/pubmed/33667909
http://dx.doi.org/10.1016/j.ijscr.2021.105706
_version_ 1783661455835398144
author Najjari, Khosrow
Gouravani, Mahdi
Hajebi, Reza
Zabihi Mahmoudabadi, Hossein
Rahimpour, Ehsan
author_facet Najjari, Khosrow
Gouravani, Mahdi
Hajebi, Reza
Zabihi Mahmoudabadi, Hossein
Rahimpour, Ehsan
author_sort Najjari, Khosrow
collection PubMed
description INTRODUCTION AND IMPORTANCE: As the population grows older, femoral neck fracture is becoming one of the prevalent cases in orthopedics, although this fracture can also happen in younger individuals following high energy traumas. Fixation with cancellous lag screws is one treatment option for femoral neck fractures, especially for young adults and relatively active older patients. CASE PRESENTATION: In this case report, we describe a 52-year-old man referred with the formation of enterocutaneous fistula (ECF) in the surgery place for fixation of a femoral neck fracture 30 years prior to presentation. CLINICAL DISCUSSION: Interpretation of CT scan images as well as findings of the performed laparotomy suggested that fixation procedure with screws was probably the main culprit for penetration of ileum. Subsequently, the removal of screws enabled the fistula to reach the surface of skin, which presented with fecal drainage. To eliminate fistula, we performed right hemicolectomy and ileocolic anastomosis for the case. CONCLUSION: Since management of ECF remains among the most challenging problems for surgeons, this unique case report indicates the possibility for formation of such fistula following a fixation procedure in the hip joint area, even after thirty years and stresses on taking measures in order to prevent fistula formation caused by the prevalent procedures performed on the hip joint.
format Online
Article
Text
id pubmed-7937741
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-79377412021-03-16 Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report Najjari, Khosrow Gouravani, Mahdi Hajebi, Reza Zabihi Mahmoudabadi, Hossein Rahimpour, Ehsan Int J Surg Case Rep Case Report INTRODUCTION AND IMPORTANCE: As the population grows older, femoral neck fracture is becoming one of the prevalent cases in orthopedics, although this fracture can also happen in younger individuals following high energy traumas. Fixation with cancellous lag screws is one treatment option for femoral neck fractures, especially for young adults and relatively active older patients. CASE PRESENTATION: In this case report, we describe a 52-year-old man referred with the formation of enterocutaneous fistula (ECF) in the surgery place for fixation of a femoral neck fracture 30 years prior to presentation. CLINICAL DISCUSSION: Interpretation of CT scan images as well as findings of the performed laparotomy suggested that fixation procedure with screws was probably the main culprit for penetration of ileum. Subsequently, the removal of screws enabled the fistula to reach the surface of skin, which presented with fecal drainage. To eliminate fistula, we performed right hemicolectomy and ileocolic anastomosis for the case. CONCLUSION: Since management of ECF remains among the most challenging problems for surgeons, this unique case report indicates the possibility for formation of such fistula following a fixation procedure in the hip joint area, even after thirty years and stresses on taking measures in order to prevent fistula formation caused by the prevalent procedures performed on the hip joint. Elsevier 2021-02-25 /pmc/articles/PMC7937741/ /pubmed/33667909 http://dx.doi.org/10.1016/j.ijscr.2021.105706 Text en © 2021 The Authors. Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Najjari, Khosrow
Gouravani, Mahdi
Hajebi, Reza
Zabihi Mahmoudabadi, Hossein
Rahimpour, Ehsan
Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report
title Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report
title_full Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report
title_fullStr Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report
title_full_unstemmed Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report
title_short Enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: A case report
title_sort enterocutaneous fistula formation thirty years after a femoral neck fracture fixation with lag screws: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7937741/
https://www.ncbi.nlm.nih.gov/pubmed/33667909
http://dx.doi.org/10.1016/j.ijscr.2021.105706
work_keys_str_mv AT najjarikhosrow enterocutaneousfistulaformationthirtyyearsafterafemoralneckfracturefixationwithlagscrewsacasereport
AT gouravanimahdi enterocutaneousfistulaformationthirtyyearsafterafemoralneckfracturefixationwithlagscrewsacasereport
AT hajebireza enterocutaneousfistulaformationthirtyyearsafterafemoralneckfracturefixationwithlagscrewsacasereport
AT zabihimahmoudabadihossein enterocutaneousfistulaformationthirtyyearsafterafemoralneckfracturefixationwithlagscrewsacasereport
AT rahimpourehsan enterocutaneousfistulaformationthirtyyearsafterafemoralneckfracturefixationwithlagscrewsacasereport