Cargando…

Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy

OBJECTIVE: Whether the original dosimetric constraints of neuro-optic structures (NOS) are appropriate for patients with nasopharyngeal carcinoma (NPC) undergoing intensity-modulated radiotherapy (IMRT) remains controversial. The present study compared the survival rates and radiation-induced optic...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Tingting, Xu, Meng, Mi, Jinglin, Yang, Hui, Liu, Zhengchun, Huang, Lulu, Hu, Kai, Wang, Rensheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7937960/
https://www.ncbi.nlm.nih.gov/pubmed/33692949
http://dx.doi.org/10.3389/fonc.2021.598320
_version_ 1783661502437261312
author Zhang, Tingting
Xu, Meng
Mi, Jinglin
Yang, Hui
Liu, Zhengchun
Huang, Lulu
Hu, Kai
Wang, Rensheng
author_facet Zhang, Tingting
Xu, Meng
Mi, Jinglin
Yang, Hui
Liu, Zhengchun
Huang, Lulu
Hu, Kai
Wang, Rensheng
author_sort Zhang, Tingting
collection PubMed
description OBJECTIVE: Whether the original dosimetric constraints of neuro-optic structures (NOS) are appropriate for patients with nasopharyngeal carcinoma (NPC) undergoing intensity-modulated radiotherapy (IMRT) remains controversial. The present study compared the survival rates and radiation-induced optic neuropathy (RION) occurrence between T4 NPC patients whose NOS were irradiated with a near maximum dose received by 2% of the volume (D2%) >55 Gy and ≤55 Gy. Moreover, the NOS dosimetric parameters and their correlation with RION occurrence were also evaluated. METHODS: In this retrospective study, 256 T4 NPC patients treated with IMRT between May 2009 and December 2013 were included. Patient characteristics, survival rates, dosimetric parameters, and RION incidence were compared between the D2% ≤55 Gy and D2% >55 Gy groups. RESULTS: The median follow-up durations were 87 and 83 months for patients in the D2% >55 Gy and D2% ≤55 Gy groups, respectively. The 5-year local recurrence-free survival rates were 92.0 and 84.0% in the D2% >55 Gy and D2% ≤55 Gy groups (P = 0.043), respectively. There was no significant difference in the 5-year overall survival (OS) between both groups (D2% >55 Gy, 81.6%; D2% ≤55 Gy, 79.4%; P = 0.586). No patients developed severe RION (Grades 3–5), and there was no significant difference (P = 0.958) in the incidence of RION between the two groups. The maximum dose of NOS significantly affected the RION incidence, with a cutoff point of 70.77 Gy. CONCLUSION: Appropriately loosening NOS dosimetric constraints in order to ensure a more sufficient dose to the target volume can provide a better 5-year local recurrence-free survival and acceptable neuro-optic toxicity in T4 NPC patients undergoing IMRT.
format Online
Article
Text
id pubmed-7937960
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-79379602021-03-09 Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy Zhang, Tingting Xu, Meng Mi, Jinglin Yang, Hui Liu, Zhengchun Huang, Lulu Hu, Kai Wang, Rensheng Front Oncol Oncology OBJECTIVE: Whether the original dosimetric constraints of neuro-optic structures (NOS) are appropriate for patients with nasopharyngeal carcinoma (NPC) undergoing intensity-modulated radiotherapy (IMRT) remains controversial. The present study compared the survival rates and radiation-induced optic neuropathy (RION) occurrence between T4 NPC patients whose NOS were irradiated with a near maximum dose received by 2% of the volume (D2%) >55 Gy and ≤55 Gy. Moreover, the NOS dosimetric parameters and their correlation with RION occurrence were also evaluated. METHODS: In this retrospective study, 256 T4 NPC patients treated with IMRT between May 2009 and December 2013 were included. Patient characteristics, survival rates, dosimetric parameters, and RION incidence were compared between the D2% ≤55 Gy and D2% >55 Gy groups. RESULTS: The median follow-up durations were 87 and 83 months for patients in the D2% >55 Gy and D2% ≤55 Gy groups, respectively. The 5-year local recurrence-free survival rates were 92.0 and 84.0% in the D2% >55 Gy and D2% ≤55 Gy groups (P = 0.043), respectively. There was no significant difference in the 5-year overall survival (OS) between both groups (D2% >55 Gy, 81.6%; D2% ≤55 Gy, 79.4%; P = 0.586). No patients developed severe RION (Grades 3–5), and there was no significant difference (P = 0.958) in the incidence of RION between the two groups. The maximum dose of NOS significantly affected the RION incidence, with a cutoff point of 70.77 Gy. CONCLUSION: Appropriately loosening NOS dosimetric constraints in order to ensure a more sufficient dose to the target volume can provide a better 5-year local recurrence-free survival and acceptable neuro-optic toxicity in T4 NPC patients undergoing IMRT. Frontiers Media S.A. 2021-02-22 /pmc/articles/PMC7937960/ /pubmed/33692949 http://dx.doi.org/10.3389/fonc.2021.598320 Text en Copyright © 2021 Zhang, Xu, Mi, Yang, Liu, Huang, Hu and Wang http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Zhang, Tingting
Xu, Meng
Mi, Jinglin
Yang, Hui
Liu, Zhengchun
Huang, Lulu
Hu, Kai
Wang, Rensheng
Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy
title Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy
title_full Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy
title_fullStr Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy
title_full_unstemmed Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy
title_short Loosening Neuro-Optic Structures Dosimetric Constraints Provides High 5-Year Local Recurrence-Free Survival With Acceptable Toxicity in T4 Nasopharyngeal Carcinoma Patients Treated With Intensity-Modulated Radiotherapy
title_sort loosening neuro-optic structures dosimetric constraints provides high 5-year local recurrence-free survival with acceptable toxicity in t4 nasopharyngeal carcinoma patients treated with intensity-modulated radiotherapy
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7937960/
https://www.ncbi.nlm.nih.gov/pubmed/33692949
http://dx.doi.org/10.3389/fonc.2021.598320
work_keys_str_mv AT zhangtingting looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy
AT xumeng looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy
AT mijinglin looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy
AT yanghui looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy
AT liuzhengchun looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy
AT huanglulu looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy
AT hukai looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy
AT wangrensheng looseningneuroopticstructuresdosimetricconstraintsprovideshigh5yearlocalrecurrencefreesurvivalwithacceptabletoxicityint4nasopharyngealcarcinomapatientstreatedwithintensitymodulatedradiotherapy