Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry
Liquid Chromatography tandem mass spectrometry (LC-MS/MS) is the gold-standard approach for androgen analysis in biological fluids, superseding immunoassays in selectivity, particularly at low concentrations. While LC-MS/MS is established for analysis of testosterone and androstenedione, 5α-dihydrot...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7938423/ https://www.ncbi.nlm.nih.gov/pubmed/33588275 http://dx.doi.org/10.1016/j.chroma.2021.461933 |
_version_ | 1783661592793055232 |
---|---|
author | Faqehi, Abdullah MM Denham, Scott G Naredo, Gregorio Cobice, Diego F Khan, Shazia Simpson, Joanna P Sabil, Ghazali Upreti, Rita Gibb, Fraser Homer, Natalie ZM Andrew, Ruth |
author_facet | Faqehi, Abdullah MM Denham, Scott G Naredo, Gregorio Cobice, Diego F Khan, Shazia Simpson, Joanna P Sabil, Ghazali Upreti, Rita Gibb, Fraser Homer, Natalie ZM Andrew, Ruth |
author_sort | Faqehi, Abdullah MM |
collection | PubMed |
description | Liquid Chromatography tandem mass spectrometry (LC-MS/MS) is the gold-standard approach for androgen analysis in biological fluids, superseding immunoassays in selectivity, particularly at low concentrations. While LC-MS/MS is established for analysis of testosterone and androstenedione, 5α-dihydrotestosterone (DHT) presents greater analytical challenges. DHT circulates at low nanomolar concentrations in men and lower in women, ionizing inefficiently and suffering from isobaric interference from other androgens. Even using current LC-MS/MS technology, large plasma volumes (>0.5 mL) are required for detection, undesirable clinically and unsuitable for animals. This study investigated derivatization approaches using hydrazine-based reagents to enhance ionization efficiency and sensitivity of analysis of DHT by LC-MS/MS. Derivatization of DHT using 2-hydrazino-1-methylpyridine (HMP) and 2-hydrazino-4-(trifluoromethyl)-pyrimidine (HTP) were compared. A method was validated using an UHPLC interfaced by electrospray with a triple quadruple mass spectrometer , analyzing human plasma (male and post-menopausal women) following solid-phase extraction. HMP derivatives were selected for validation affording greater sensitivity than those formed with HTP. HMP derivatives were detected by selected reaction monitoring (DHT-HMP m/z 396→108; testosterone-HMP m/z 394→108; androstenedione-HMP m/z 392→108). Chromatographic separation of androgen derivatives was optimized, carefully separating isobaric interferents and acceptable outputs for precision and trueness achieved following injection of 0.4 pg on column (approximately 34 pmol/L). HMP derivatives of all androgens tested could be detected in low plasma volumes: male (100 µL) and post-menopausal female (200 µL), and derivatives were stable over 30 days at -20°C. In conclusion, HMP derivatization, in conjunction with LC-MS/MS, is suitable for quantitative analysis of DHT, testosterone and androstenedione in low plasma volumes, offering advantages in sensitivity over current methodologies. |
format | Online Article Text |
id | pubmed-7938423 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-79384232021-03-16 Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry Faqehi, Abdullah MM Denham, Scott G Naredo, Gregorio Cobice, Diego F Khan, Shazia Simpson, Joanna P Sabil, Ghazali Upreti, Rita Gibb, Fraser Homer, Natalie ZM Andrew, Ruth J Chromatogr A Article Liquid Chromatography tandem mass spectrometry (LC-MS/MS) is the gold-standard approach for androgen analysis in biological fluids, superseding immunoassays in selectivity, particularly at low concentrations. While LC-MS/MS is established for analysis of testosterone and androstenedione, 5α-dihydrotestosterone (DHT) presents greater analytical challenges. DHT circulates at low nanomolar concentrations in men and lower in women, ionizing inefficiently and suffering from isobaric interference from other androgens. Even using current LC-MS/MS technology, large plasma volumes (>0.5 mL) are required for detection, undesirable clinically and unsuitable for animals. This study investigated derivatization approaches using hydrazine-based reagents to enhance ionization efficiency and sensitivity of analysis of DHT by LC-MS/MS. Derivatization of DHT using 2-hydrazino-1-methylpyridine (HMP) and 2-hydrazino-4-(trifluoromethyl)-pyrimidine (HTP) were compared. A method was validated using an UHPLC interfaced by electrospray with a triple quadruple mass spectrometer , analyzing human plasma (male and post-menopausal women) following solid-phase extraction. HMP derivatives were selected for validation affording greater sensitivity than those formed with HTP. HMP derivatives were detected by selected reaction monitoring (DHT-HMP m/z 396→108; testosterone-HMP m/z 394→108; androstenedione-HMP m/z 392→108). Chromatographic separation of androgen derivatives was optimized, carefully separating isobaric interferents and acceptable outputs for precision and trueness achieved following injection of 0.4 pg on column (approximately 34 pmol/L). HMP derivatives of all androgens tested could be detected in low plasma volumes: male (100 µL) and post-menopausal female (200 µL), and derivatives were stable over 30 days at -20°C. In conclusion, HMP derivatization, in conjunction with LC-MS/MS, is suitable for quantitative analysis of DHT, testosterone and androstenedione in low plasma volumes, offering advantages in sensitivity over current methodologies. Elsevier 2021-03-15 /pmc/articles/PMC7938423/ /pubmed/33588275 http://dx.doi.org/10.1016/j.chroma.2021.461933 Text en © 2021 The Authors. Published by Elsevier B.V. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Faqehi, Abdullah MM Denham, Scott G Naredo, Gregorio Cobice, Diego F Khan, Shazia Simpson, Joanna P Sabil, Ghazali Upreti, Rita Gibb, Fraser Homer, Natalie ZM Andrew, Ruth Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry |
title | Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry |
title_full | Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry |
title_fullStr | Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry |
title_full_unstemmed | Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry |
title_short | Derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry |
title_sort | derivatization with 2-hydrazino-1-methylpyridine enhances sensitivity of analysis of 5α-dihydrotestosterone in human plasma by liquid chromatography tandem mass spectrometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7938423/ https://www.ncbi.nlm.nih.gov/pubmed/33588275 http://dx.doi.org/10.1016/j.chroma.2021.461933 |
work_keys_str_mv | AT faqehiabdullahmm derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT denhamscottg derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT naredogregorio derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT cobicediegof derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT khanshazia derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT simpsonjoannap derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT sabilghazali derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT upretirita derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT gibbfraser derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT homernataliezm derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry AT andrewruth derivatizationwith2hydrazino1methylpyridineenhancessensitivityofanalysisof5adihydrotestosteroneinhumanplasmabyliquidchromatographytandemmassspectrometry |