Cargando…

Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spreading all over the world and has caused millions of deaths. Several sample-to-answer platforms, including Cepheid Xpert Xpress SARS-CoV-2 (Xpert Xpress), have received emergency use authorization for SARS-CoV-2 nucleic acid detectio...

Descripción completa

Detalles Bibliográficos
Autores principales: Wen, Donghua, Yang, Simin, Li, Guangbo, Xuan, Qiankun, Guo, Wenzheng, Wu, Wenjuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Association for Molecular Pathology and American Society for Investigative Pathology. Published by Elsevier Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7938732/
https://www.ncbi.nlm.nih.gov/pubmed/33706011
http://dx.doi.org/10.1016/j.jmoldx.2021.02.010
_version_ 1783661643839832064
author Wen, Donghua
Yang, Simin
Li, Guangbo
Xuan, Qiankun
Guo, Wenzheng
Wu, Wenjuan
author_facet Wen, Donghua
Yang, Simin
Li, Guangbo
Xuan, Qiankun
Guo, Wenzheng
Wu, Wenjuan
author_sort Wen, Donghua
collection PubMed
description Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spreading all over the world and has caused millions of deaths. Several sample-to-answer platforms, including Cepheid Xpert Xpress SARS-CoV-2 (Xpert Xpress), have received emergency use authorization for SARS-CoV-2 nucleic acid detection as a point of care test in the United States. However, their application niche is unclear when compared with real-time RT-PCR assays cleared by the National Medical Products Administration in China. In this study, the clinical performance, sensitivity, and workflow of Xpert Xpress and two real-time RT-PCR kits (BioGerm kit and Sansure kit) were evaluated by the specimens from 86 symptomatic patients. The positive percent agreement of Xpert Xpress was 100% compared with 96.15% for the BioGerm kit and 90% for the Sansure kit. The negative percent agreement was 100% for all three assays. The limit of detection is 100 copies/mL for Xpert Xpress and 500 copies/mL for the BioGerm kit and Sansure kit. By serially diluting five positive specimens, the Xpert Xpress had better detection capability. In the workflow and throughput analysis, the turnaround time was 51 minutes for Xpert Xpress, 150 minutes for the BioGerm kit, and 210 minutes for the Sansure kit. This study provides some indication for diagnosis methods selection.
format Online
Article
Text
id pubmed-7938732
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Association for Molecular Pathology and American Society for Investigative Pathology. Published by Elsevier Inc.
record_format MEDLINE/PubMed
spelling pubmed-79387322021-03-09 Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection Wen, Donghua Yang, Simin Li, Guangbo Xuan, Qiankun Guo, Wenzheng Wu, Wenjuan J Mol Diagn Technical Advance Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spreading all over the world and has caused millions of deaths. Several sample-to-answer platforms, including Cepheid Xpert Xpress SARS-CoV-2 (Xpert Xpress), have received emergency use authorization for SARS-CoV-2 nucleic acid detection as a point of care test in the United States. However, their application niche is unclear when compared with real-time RT-PCR assays cleared by the National Medical Products Administration in China. In this study, the clinical performance, sensitivity, and workflow of Xpert Xpress and two real-time RT-PCR kits (BioGerm kit and Sansure kit) were evaluated by the specimens from 86 symptomatic patients. The positive percent agreement of Xpert Xpress was 100% compared with 96.15% for the BioGerm kit and 90% for the Sansure kit. The negative percent agreement was 100% for all three assays. The limit of detection is 100 copies/mL for Xpert Xpress and 500 copies/mL for the BioGerm kit and Sansure kit. By serially diluting five positive specimens, the Xpert Xpress had better detection capability. In the workflow and throughput analysis, the turnaround time was 51 minutes for Xpert Xpress, 150 minutes for the BioGerm kit, and 210 minutes for the Sansure kit. This study provides some indication for diagnosis methods selection. Association for Molecular Pathology and American Society for Investigative Pathology. Published by Elsevier Inc. 2021-06 2021-03-08 /pmc/articles/PMC7938732/ /pubmed/33706011 http://dx.doi.org/10.1016/j.jmoldx.2021.02.010 Text en © 2021 Association for Molecular Pathology and American Society for Investigative Pathology. Published by Elsevier Inc. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Technical Advance
Wen, Donghua
Yang, Simin
Li, Guangbo
Xuan, Qiankun
Guo, Wenzheng
Wu, Wenjuan
Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection
title Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection
title_full Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection
title_fullStr Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection
title_full_unstemmed Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection
title_short Sample-to-Answer and Routine Real-Time RT-PCR: A Comparison of Different Platforms for SARS-CoV-2 Detection
title_sort sample-to-answer and routine real-time rt-pcr: a comparison of different platforms for sars-cov-2 detection
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7938732/
https://www.ncbi.nlm.nih.gov/pubmed/33706011
http://dx.doi.org/10.1016/j.jmoldx.2021.02.010
work_keys_str_mv AT wendonghua sampletoanswerandroutinerealtimertpcracomparisonofdifferentplatformsforsarscov2detection
AT yangsimin sampletoanswerandroutinerealtimertpcracomparisonofdifferentplatformsforsarscov2detection
AT liguangbo sampletoanswerandroutinerealtimertpcracomparisonofdifferentplatformsforsarscov2detection
AT xuanqiankun sampletoanswerandroutinerealtimertpcracomparisonofdifferentplatformsforsarscov2detection
AT guowenzheng sampletoanswerandroutinerealtimertpcracomparisonofdifferentplatformsforsarscov2detection
AT wuwenjuan sampletoanswerandroutinerealtimertpcracomparisonofdifferentplatformsforsarscov2detection