Cargando…

Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis

Background: There are limited data comparing clinical outcomes between biodegradable polymer and durable polymer drug-eluting stents (BP-DES and DP-DES, respectively) in patients with end-stage renal disease (ESRD). Methods and Results: This study enrolled 229 ESRD patients who underwent successful...

Descripción completa

Detalles Bibliográficos
Autores principales: Okuno, Shota, Ishihara, Takayuki, Iida, Osamu, Asai, Mitsutoshi, Masuda, Masaharu, Okamoto, Shin, Nanto, Kiyonori, Kanda, Takashi, Tsujimura, Takuya, Matsuda, Yasuhiro, Hata, Yosuke, Mano, Toshiaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Circulation Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7939789/
https://www.ncbi.nlm.nih.gov/pubmed/33693286
http://dx.doi.org/10.1253/circrep.CR-20-0120
_version_ 1783661815079632896
author Okuno, Shota
Ishihara, Takayuki
Iida, Osamu
Asai, Mitsutoshi
Masuda, Masaharu
Okamoto, Shin
Nanto, Kiyonori
Kanda, Takashi
Tsujimura, Takuya
Matsuda, Yasuhiro
Hata, Yosuke
Mano, Toshiaki
author_facet Okuno, Shota
Ishihara, Takayuki
Iida, Osamu
Asai, Mitsutoshi
Masuda, Masaharu
Okamoto, Shin
Nanto, Kiyonori
Kanda, Takashi
Tsujimura, Takuya
Matsuda, Yasuhiro
Hata, Yosuke
Mano, Toshiaki
author_sort Okuno, Shota
collection PubMed
description Background: There are limited data comparing clinical outcomes between biodegradable polymer and durable polymer drug-eluting stents (BP-DES and DP-DES, respectively) in patients with end-stage renal disease (ESRD). Methods and Results: This study enrolled 229 ESRD patients who underwent successful percutaneous coronary intervention (PCI) for 400 lesions with 472 DES, with 2-year clinical outcomes compared between the BP-DES and DP-DES groups. The primary outcome measure was the incidence of target lesion revascularization (TLR), whereas secondary outcome measures were the occurrence of cardiac death (CD), myocardial infraction (MI), stent thrombosis (ST), target vessel revascularization (TVR), non-TVR, and major adverse cardiac events (MACE), defined as a composite of CD, MI, and TVR. Multivariate analysis was used to identify predictors of TLR occurrence. The 2-year incidence of TLR did not differ significantly between the BP-DES and DP-DES groups (P=0.274). In addition, there were no significant differences in the 2-year incidence of CD (P=0.144), MI (P=0.812), ST (P=0.241), TVR (P=0.434), non-TVR (P=0.375), or MACE (P=0.841) between the 2 groups. Multivariate analysis showed that diabetes (P=0.021) was independently associated with TLR occurrence. Conclusions: BP-DES and DP-DES had comparable safety and efficacy profiles over a 2-year follow-up period after PCI in ESRD patients.
format Online
Article
Text
id pubmed-7939789
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Japanese Circulation Society
record_format MEDLINE/PubMed
spelling pubmed-79397892021-03-09 Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis Okuno, Shota Ishihara, Takayuki Iida, Osamu Asai, Mitsutoshi Masuda, Masaharu Okamoto, Shin Nanto, Kiyonori Kanda, Takashi Tsujimura, Takuya Matsuda, Yasuhiro Hata, Yosuke Mano, Toshiaki Circ Rep Original article Background: There are limited data comparing clinical outcomes between biodegradable polymer and durable polymer drug-eluting stents (BP-DES and DP-DES, respectively) in patients with end-stage renal disease (ESRD). Methods and Results: This study enrolled 229 ESRD patients who underwent successful percutaneous coronary intervention (PCI) for 400 lesions with 472 DES, with 2-year clinical outcomes compared between the BP-DES and DP-DES groups. The primary outcome measure was the incidence of target lesion revascularization (TLR), whereas secondary outcome measures were the occurrence of cardiac death (CD), myocardial infraction (MI), stent thrombosis (ST), target vessel revascularization (TVR), non-TVR, and major adverse cardiac events (MACE), defined as a composite of CD, MI, and TVR. Multivariate analysis was used to identify predictors of TLR occurrence. The 2-year incidence of TLR did not differ significantly between the BP-DES and DP-DES groups (P=0.274). In addition, there were no significant differences in the 2-year incidence of CD (P=0.144), MI (P=0.812), ST (P=0.241), TVR (P=0.434), non-TVR (P=0.375), or MACE (P=0.841) between the 2 groups. Multivariate analysis showed that diabetes (P=0.021) was independently associated with TLR occurrence. Conclusions: BP-DES and DP-DES had comparable safety and efficacy profiles over a 2-year follow-up period after PCI in ESRD patients. The Japanese Circulation Society 2020-12-15 /pmc/articles/PMC7939789/ /pubmed/33693286 http://dx.doi.org/10.1253/circrep.CR-20-0120 Text en Copyright © 2021, THE JAPANESE CIRCULATION SOCIETY This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Original article
Okuno, Shota
Ishihara, Takayuki
Iida, Osamu
Asai, Mitsutoshi
Masuda, Masaharu
Okamoto, Shin
Nanto, Kiyonori
Kanda, Takashi
Tsujimura, Takuya
Matsuda, Yasuhiro
Hata, Yosuke
Mano, Toshiaki
Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis
title Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis
title_full Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis
title_fullStr Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis
title_full_unstemmed Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis
title_short Two-Year Clinical Outcomes of Biodegradable Polymer vs. Durable Polymer Drug-Eluting Stent Implantation in Patients With End-Stage Renal Disease on Dialysis
title_sort two-year clinical outcomes of biodegradable polymer vs. durable polymer drug-eluting stent implantation in patients with end-stage renal disease on dialysis
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7939789/
https://www.ncbi.nlm.nih.gov/pubmed/33693286
http://dx.doi.org/10.1253/circrep.CR-20-0120
work_keys_str_mv AT okunoshota twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT ishiharatakayuki twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT iidaosamu twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT asaimitsutoshi twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT masudamasaharu twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT okamotoshin twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT nantokiyonori twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT kandatakashi twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT tsujimuratakuya twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT matsudayasuhiro twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT hatayosuke twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis
AT manotoshiaki twoyearclinicaloutcomesofbiodegradablepolymervsdurablepolymerdrugelutingstentimplantationinpatientswithendstagerenaldiseaseondialysis