Cargando…
Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7940397/ https://www.ncbi.nlm.nih.gov/pubmed/33686152 http://dx.doi.org/10.1038/s41598-021-84885-4 |
_version_ | 1783661945314869248 |
---|---|
author | Iida, Yuuki Hongo, Kumiko Onoda, Takanobu Kita, Yusuke Ishihara, Yukio Takabayashi, Naoki Kobayashi, Ryo Hiramatsu, Takeyuki |
author_facet | Iida, Yuuki Hongo, Kumiko Onoda, Takanobu Kita, Yusuke Ishihara, Yukio Takabayashi, Naoki Kobayashi, Ryo Hiramatsu, Takeyuki |
author_sort | Iida, Yuuki |
collection | PubMed |
description | Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection. |
format | Online Article Text |
id | pubmed-7940397 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-79403972021-03-10 Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port Iida, Yuuki Hongo, Kumiko Onoda, Takanobu Kita, Yusuke Ishihara, Yukio Takabayashi, Naoki Kobayashi, Ryo Hiramatsu, Takeyuki Sci Rep Article Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection. Nature Publishing Group UK 2021-03-08 /pmc/articles/PMC7940397/ /pubmed/33686152 http://dx.doi.org/10.1038/s41598-021-84885-4 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Iida, Yuuki Hongo, Kumiko Onoda, Takanobu Kita, Yusuke Ishihara, Yukio Takabayashi, Naoki Kobayashi, Ryo Hiramatsu, Takeyuki Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port |
title | Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port |
title_full | Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port |
title_fullStr | Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port |
title_full_unstemmed | Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port |
title_short | Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port |
title_sort | use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7940397/ https://www.ncbi.nlm.nih.gov/pubmed/33686152 http://dx.doi.org/10.1038/s41598-021-84885-4 |
work_keys_str_mv | AT iidayuuki useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport AT hongokumiko useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport AT onodatakanobu useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport AT kitayusuke useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport AT ishiharayukio useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport AT takabayashinaoki useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport AT kobayashiryo useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport AT hiramatsutakeyuki useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport |