Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port

Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsi...

Descripción completa

Detalles Bibliográficos
Autores principales: Iida, Yuuki, Hongo, Kumiko, Onoda, Takanobu, Kita, Yusuke, Ishihara, Yukio, Takabayashi, Naoki, Kobayashi, Ryo, Hiramatsu, Takeyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7940397/
https://www.ncbi.nlm.nih.gov/pubmed/33686152
http://dx.doi.org/10.1038/s41598-021-84885-4
_version_ 1783661945314869248
author Iida, Yuuki
Hongo, Kumiko
Onoda, Takanobu
Kita, Yusuke
Ishihara, Yukio
Takabayashi, Naoki
Kobayashi, Ryo
Hiramatsu, Takeyuki
author_facet Iida, Yuuki
Hongo, Kumiko
Onoda, Takanobu
Kita, Yusuke
Ishihara, Yukio
Takabayashi, Naoki
Kobayashi, Ryo
Hiramatsu, Takeyuki
author_sort Iida, Yuuki
collection PubMed
description Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection.
format Online
Article
Text
id pubmed-7940397
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-79403972021-03-10 Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port Iida, Yuuki Hongo, Kumiko Onoda, Takanobu Kita, Yusuke Ishihara, Yukio Takabayashi, Naoki Kobayashi, Ryo Hiramatsu, Takeyuki Sci Rep Article Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection. Nature Publishing Group UK 2021-03-08 /pmc/articles/PMC7940397/ /pubmed/33686152 http://dx.doi.org/10.1038/s41598-021-84885-4 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Iida, Yuuki
Hongo, Kumiko
Onoda, Takanobu
Kita, Yusuke
Ishihara, Yukio
Takabayashi, Naoki
Kobayashi, Ryo
Hiramatsu, Takeyuki
Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
title Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
title_full Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
title_fullStr Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
title_full_unstemmed Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
title_short Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
title_sort use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7940397/
https://www.ncbi.nlm.nih.gov/pubmed/33686152
http://dx.doi.org/10.1038/s41598-021-84885-4
work_keys_str_mv AT iidayuuki useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport
AT hongokumiko useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport
AT onodatakanobu useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport
AT kitayusuke useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport
AT ishiharayukio useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport
AT takabayashinaoki useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport
AT kobayashiryo useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport
AT hiramatsutakeyuki useofcatheterwith2methacryloyloxyethylphosphorylcholinepolymercoatingisassociatedwithlongtermavailabilityofcentralvenousport