Cargando…
PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study
INTRODUCTION: The aim of this retrospective study was to evaluate the outcomes of older patients with 2-part proximal humerus fractures (PHFs) with medial column disruption stabilized using a proximal humeral internal locking system (PHILOS) plate plus oblique insertion of autologous fibula as a pri...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7940727/ https://www.ncbi.nlm.nih.gov/pubmed/33747609 http://dx.doi.org/10.1177/2151459321992666 |
_version_ | 1783662002441289728 |
---|---|
author | Shu, Ying Chen, Meiji Yu, Weiguang Ge, Zhe Hu, Hao Zhang, Xinchao Zeng, Xianshang Liu, Xiangzhen |
author_facet | Shu, Ying Chen, Meiji Yu, Weiguang Ge, Zhe Hu, Hao Zhang, Xinchao Zeng, Xianshang Liu, Xiangzhen |
author_sort | Shu, Ying |
collection | PubMed |
description | INTRODUCTION: The aim of this retrospective study was to evaluate the outcomes of older patients with 2-part proximal humerus fractures (PHFs) with medial column disruption stabilized using a proximal humeral internal locking system (PHILOS) plate plus oblique insertion of autologous fibula as a primary procedure. MATERIALS AND METHODS: Data involving 112 patients (112 shoulders) sustaining 2-part PHFs with medial column disruption treated with PHILOS plate plus oblique insertion of autologous fibula as a primary procedure during 2012-2019 were identified. The median follow-up was 36 months (range: 11.2-43.5 months). The primary endpoint was the Constant scores and American Shoulder and Elbow Surgeons (ASES) scores. The secondary endpoint was the main orthopedic complication rate. RESULTS: The median Constant and ASES scores were 78 (range, 52-95) and 77 (range, 62-96) at the final follow-up, respectively. The main orthopedic complication rate was 10.7% (12/112). Twelve orthopedic complications in 8 patients were detected, and they involved loss of reduction, varus collapse, aseptic loosening, mal-union, revision, and intolerable shoulder pain. Of these complications, 3 (2.6%) involved loss of reduction, 2 (1.7%) involved varus collapse, 3 (2.6%) involved aseptic loosening, 1 (0.8%) involved mal-union, 2 (1.7%) required revision surgery, and 1 (0.8%) presented intolerable shoulder pain. CONCLUSION: PHILOS plate plus oblique insertion of autologous fibula as a primary procedure may yield good functional outcomes and a low rate of the main orthopedic complications. |
format | Online Article Text |
id | pubmed-7940727 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-79407272021-03-18 PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study Shu, Ying Chen, Meiji Yu, Weiguang Ge, Zhe Hu, Hao Zhang, Xinchao Zeng, Xianshang Liu, Xiangzhen Geriatr Orthop Surg Rehabil Original Manuscript INTRODUCTION: The aim of this retrospective study was to evaluate the outcomes of older patients with 2-part proximal humerus fractures (PHFs) with medial column disruption stabilized using a proximal humeral internal locking system (PHILOS) plate plus oblique insertion of autologous fibula as a primary procedure. MATERIALS AND METHODS: Data involving 112 patients (112 shoulders) sustaining 2-part PHFs with medial column disruption treated with PHILOS plate plus oblique insertion of autologous fibula as a primary procedure during 2012-2019 were identified. The median follow-up was 36 months (range: 11.2-43.5 months). The primary endpoint was the Constant scores and American Shoulder and Elbow Surgeons (ASES) scores. The secondary endpoint was the main orthopedic complication rate. RESULTS: The median Constant and ASES scores were 78 (range, 52-95) and 77 (range, 62-96) at the final follow-up, respectively. The main orthopedic complication rate was 10.7% (12/112). Twelve orthopedic complications in 8 patients were detected, and they involved loss of reduction, varus collapse, aseptic loosening, mal-union, revision, and intolerable shoulder pain. Of these complications, 3 (2.6%) involved loss of reduction, 2 (1.7%) involved varus collapse, 3 (2.6%) involved aseptic loosening, 1 (0.8%) involved mal-union, 2 (1.7%) required revision surgery, and 1 (0.8%) presented intolerable shoulder pain. CONCLUSION: PHILOS plate plus oblique insertion of autologous fibula as a primary procedure may yield good functional outcomes and a low rate of the main orthopedic complications. SAGE Publications 2021-03-04 /pmc/articles/PMC7940727/ /pubmed/33747609 http://dx.doi.org/10.1177/2151459321992666 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Manuscript Shu, Ying Chen, Meiji Yu, Weiguang Ge, Zhe Hu, Hao Zhang, Xinchao Zeng, Xianshang Liu, Xiangzhen PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study |
title | PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study |
title_full | PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study |
title_fullStr | PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study |
title_full_unstemmed | PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study |
title_short | PHILOS Plate Plus Oblique Insertion of Autologous Fibula for 2-Part Proximal Humerus Fractures With Medial Column Disruption: A Retrospective Study |
title_sort | philos plate plus oblique insertion of autologous fibula for 2-part proximal humerus fractures with medial column disruption: a retrospective study |
topic | Original Manuscript |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7940727/ https://www.ncbi.nlm.nih.gov/pubmed/33747609 http://dx.doi.org/10.1177/2151459321992666 |
work_keys_str_mv | AT shuying philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy AT chenmeiji philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy AT yuweiguang philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy AT gezhe philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy AT huhao philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy AT zhangxinchao philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy AT zengxianshang philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy AT liuxiangzhen philosplateplusobliqueinsertionofautologousfibulafor2partproximalhumerusfractureswithmedialcolumndisruptionaretrospectivestudy |