Cargando…
Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens
Posterior dislocation of the intraocular lens (IOL) is a rare but potentially dangerous complication encountered by a cataract surgeon. We describe a modified balanced two-string technique of internally fixing a posteriorly dislocated rigid IOL using the pars plana approach in eyes which lack adequa...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7942082/ https://www.ncbi.nlm.nih.gov/pubmed/33595521 http://dx.doi.org/10.4103/ijo.IJO_922_20 |
_version_ | 1783662247747256320 |
---|---|
author | Kumar, R Madhu Konana, Vinaya Kumar Kanakamedla, Ashok Gudimetla, Jayamadhury Poluri, Swarnalatha Potti, Sudhakar |
author_facet | Kumar, R Madhu Konana, Vinaya Kumar Kanakamedla, Ashok Gudimetla, Jayamadhury Poluri, Swarnalatha Potti, Sudhakar |
author_sort | Kumar, R Madhu |
collection | PubMed |
description | Posterior dislocation of the intraocular lens (IOL) is a rare but potentially dangerous complication encountered by a cataract surgeon. We describe a modified balanced two-string technique of internally fixing a posteriorly dislocated rigid IOL using the pars plana approach in eyes which lack adequate capsular support. Five eyes of five patients underwent the procedure. All eyes had successful IOL refixation. One eye had mild temporal decentration. BCVA improved in all patients. Our technique is an alternate method of scleral fixation of posteriorly dislocated IOL with advantages of minimal postoperative astigmatism, minimal anterior segment manipulation, and good IOL centration. |
format | Online Article Text |
id | pubmed-7942082 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-79420822021-03-10 Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens Kumar, R Madhu Konana, Vinaya Kumar Kanakamedla, Ashok Gudimetla, Jayamadhury Poluri, Swarnalatha Potti, Sudhakar Indian J Ophthalmol Surgical Technique Posterior dislocation of the intraocular lens (IOL) is a rare but potentially dangerous complication encountered by a cataract surgeon. We describe a modified balanced two-string technique of internally fixing a posteriorly dislocated rigid IOL using the pars plana approach in eyes which lack adequate capsular support. Five eyes of five patients underwent the procedure. All eyes had successful IOL refixation. One eye had mild temporal decentration. BCVA improved in all patients. Our technique is an alternate method of scleral fixation of posteriorly dislocated IOL with advantages of minimal postoperative astigmatism, minimal anterior segment manipulation, and good IOL centration. Wolters Kluwer - Medknow 2021-03 2021-02-17 /pmc/articles/PMC7942082/ /pubmed/33595521 http://dx.doi.org/10.4103/ijo.IJO_922_20 Text en Copyright: © 2021 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Surgical Technique Kumar, R Madhu Konana, Vinaya Kumar Kanakamedla, Ashok Gudimetla, Jayamadhury Poluri, Swarnalatha Potti, Sudhakar Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens |
title | Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens |
title_full | Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens |
title_fullStr | Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens |
title_full_unstemmed | Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens |
title_short | Modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens |
title_sort | modified balanced two-string technique of internal scleral fixation of posteriorly dislocated intraocular lens |
topic | Surgical Technique |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7942082/ https://www.ncbi.nlm.nih.gov/pubmed/33595521 http://dx.doi.org/10.4103/ijo.IJO_922_20 |
work_keys_str_mv | AT kumarrmadhu modifiedbalancedtwostringtechniqueofinternalscleralfixationofposteriorlydislocatedintraocularlens AT konanavinayakumar modifiedbalancedtwostringtechniqueofinternalscleralfixationofposteriorlydislocatedintraocularlens AT kanakamedlaashok modifiedbalancedtwostringtechniqueofinternalscleralfixationofposteriorlydislocatedintraocularlens AT gudimetlajayamadhury modifiedbalancedtwostringtechniqueofinternalscleralfixationofposteriorlydislocatedintraocularlens AT poluriswarnalatha modifiedbalancedtwostringtechniqueofinternalscleralfixationofposteriorlydislocatedintraocularlens AT pottisudhakar modifiedbalancedtwostringtechniqueofinternalscleralfixationofposteriorlydislocatedintraocularlens |