Cargando…
Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic
PURPOSE: The study uses principles of liquid and gas mechanics to verify and quantify the generation of aerosols in oculoplastic procedures, namely surgery using a scalpel, electrosurgical device, and a mechanized drill. METHODS: Surgical techniques were performed ex vivo using the electrosurgical d...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7942117/ https://www.ncbi.nlm.nih.gov/pubmed/33595513 http://dx.doi.org/10.4103/ijo.IJO_2859_20 |
_version_ | 1783662256008986624 |
---|---|
author | Gupta, Roshmi Pandey, Khushboo Thomas, Rwituja Basu, Saptarshi Shetty, Bhujang Shetty, Rohit Roy, Abhijit Sinha |
author_facet | Gupta, Roshmi Pandey, Khushboo Thomas, Rwituja Basu, Saptarshi Shetty, Bhujang Shetty, Rohit Roy, Abhijit Sinha |
author_sort | Gupta, Roshmi |
collection | PubMed |
description | PURPOSE: The study uses principles of liquid and gas mechanics to verify and quantify the generation of aerosols in oculoplastic procedures, namely surgery using a scalpel, electrosurgical device, and a mechanized drill. METHODS: Surgical techniques were performed ex vivo using the electrosurgical device, scalpel, and mechanized drill on the muscle and bone of commercially available chicken. The liquid and gas dynamics were observed using a high-speed high-resolution Photron SA5 camera (0.125 to 8 ms temporal resolution, 0.016 to 0.054 mm/pixel spatial resolution) and stroboscopic lighting (Veritas 120 E LED Constellation). The analysis was performed using in-house algorithms and ImageJ software. RESULTS: The use of a mechanized drill at 35000 rpm and a 3 mm fluted burr generated aerosol with particle size 50 to 550 microns with a spread of 1.8 m radius. Surgical smoke was generated by an electrosurgical device in both cutting and coagulation modes. Dispersion of the smoke could be controlled significantly by the use of suction, mean smoke spread ratio being 0.065 without suction and 0.002 with use of suction within 2 cm. CONCLUSION: The quantification of the aerosol generation will help surgeons take practical decisions in their surgical techniques in the pandemic era. |
format | Online Article Text |
id | pubmed-7942117 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-79421172021-03-10 Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic Gupta, Roshmi Pandey, Khushboo Thomas, Rwituja Basu, Saptarshi Shetty, Bhujang Shetty, Rohit Roy, Abhijit Sinha Indian J Ophthalmol Expedited Publication, Original Article PURPOSE: The study uses principles of liquid and gas mechanics to verify and quantify the generation of aerosols in oculoplastic procedures, namely surgery using a scalpel, electrosurgical device, and a mechanized drill. METHODS: Surgical techniques were performed ex vivo using the electrosurgical device, scalpel, and mechanized drill on the muscle and bone of commercially available chicken. The liquid and gas dynamics were observed using a high-speed high-resolution Photron SA5 camera (0.125 to 8 ms temporal resolution, 0.016 to 0.054 mm/pixel spatial resolution) and stroboscopic lighting (Veritas 120 E LED Constellation). The analysis was performed using in-house algorithms and ImageJ software. RESULTS: The use of a mechanized drill at 35000 rpm and a 3 mm fluted burr generated aerosol with particle size 50 to 550 microns with a spread of 1.8 m radius. Surgical smoke was generated by an electrosurgical device in both cutting and coagulation modes. Dispersion of the smoke could be controlled significantly by the use of suction, mean smoke spread ratio being 0.065 without suction and 0.002 with use of suction within 2 cm. CONCLUSION: The quantification of the aerosol generation will help surgeons take practical decisions in their surgical techniques in the pandemic era. Wolters Kluwer - Medknow 2021-03 2021-02-17 /pmc/articles/PMC7942117/ /pubmed/33595513 http://dx.doi.org/10.4103/ijo.IJO_2859_20 Text en Copyright: © 2021 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Expedited Publication, Original Article Gupta, Roshmi Pandey, Khushboo Thomas, Rwituja Basu, Saptarshi Shetty, Bhujang Shetty, Rohit Roy, Abhijit Sinha Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic |
title | Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic |
title_full | Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic |
title_fullStr | Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic |
title_full_unstemmed | Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic |
title_short | Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic |
title_sort | propensity of aerosol and droplet creation during oculoplastic procedures: a risk assessment with high-speed imaging amidst covid-19 pandemic |
topic | Expedited Publication, Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7942117/ https://www.ncbi.nlm.nih.gov/pubmed/33595513 http://dx.doi.org/10.4103/ijo.IJO_2859_20 |
work_keys_str_mv | AT guptaroshmi propensityofaerosolanddropletcreationduringoculoplasticproceduresariskassessmentwithhighspeedimagingamidstcovid19pandemic AT pandeykhushboo propensityofaerosolanddropletcreationduringoculoplasticproceduresariskassessmentwithhighspeedimagingamidstcovid19pandemic AT thomasrwituja propensityofaerosolanddropletcreationduringoculoplasticproceduresariskassessmentwithhighspeedimagingamidstcovid19pandemic AT basusaptarshi propensityofaerosolanddropletcreationduringoculoplasticproceduresariskassessmentwithhighspeedimagingamidstcovid19pandemic AT shettybhujang propensityofaerosolanddropletcreationduringoculoplasticproceduresariskassessmentwithhighspeedimagingamidstcovid19pandemic AT shettyrohit propensityofaerosolanddropletcreationduringoculoplasticproceduresariskassessmentwithhighspeedimagingamidstcovid19pandemic AT royabhijitsinha propensityofaerosolanddropletcreationduringoculoplasticproceduresariskassessmentwithhighspeedimagingamidstcovid19pandemic |